Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P0AE6-225    Hybrid Battery Precharge Contactor Control Circuit Low

for Preparation Click here


DESCRIPTION

The SMRs (System Main Relays) are the relays that connect or disconnect the high voltage power system in accordance with commands from the power management control ECU.
There are 3 SMRs and 1 precharge resistor. SMRB, SMRP, SMRG, and the precharge resistor are located in the HV battery junction block assembly in the HV battery pack.
To connect to the high voltage power system, the vehicle will first turn on SMRP and SMRB to charge the vehicle through the system main resistor. Then, SMRP will be turned off after SMRG is turned on. To shut off the high voltage power system, SMRB and SMRG are turned off.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0AE6
225
Short to GND in the SMRP circuit
Primary circuit of SMRP is malfunctioning.
(2 trip detection logic)
  1. Wire harness or connector
  2. Hybrid battery junction block assembly
  3. Power management control ECU

Related Data List 
DTC No.
Data List
P0AE6-225
  1. VL-Voltage before Boosting
  2. VH-Voltage after Boosting
  3. Power Resource VB
  4. SMRP Status
  5. SMRB Status
  6. SMRG Status
  7. SMRP Control Status
  8. SMRB Control Status
  9. SMRG Control Status
  10. Conv Shutdown
  11. MG2 Inverter Shutdown
  12. MG1 Inverter Shutdown

WIRING DIAGRAM


A243886E02


INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

HINT:
  1. If DTC P0AE6-225 is output, the power switch cannot be turned on (READY).
  2. After the repair, clear the DTCs, perform the following procedure and check that the same DTC (including pending DTC) is not output.
    1. Turn the power switch off and wait for 30 seconds or more.
    2. Turn the power switch on (READY) and wait for 30 seconds or more.
    3. Turn the power switch off and wait for 60 seconds or more.

1.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)
  1. Disconnect connector L5 from the power management control ECU.



    A204445E09
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    L5-3 (SMRP) - Body ground
    Power switch off
    112 to 274 Ω

    Text in Illustration 
    *1
    Rear view of wire harness connector
    (to Power Management Control ECU)

  1. Connect the power management control ECU connector.



NG
Go to step 2
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)  

2.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the upper hybrid battery cover sub-assembly (Click here).

  1. Disconnect connector c3 from the hybrid battery junction block assembly.

  1. Disconnect connector L5 from the power management control ECU.



    A213116E12
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    L5-3 (SMRP) and c3-3 (SMRP) - Body ground and other terminals
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *1
    Rear view of wire harness connector
    (to Power Management Control ECU)
    *2
    Rear view of wire harness connector
    (to Hybrid Battery Junction Block Assembly)

  1. Connect the power management control ECU connector.

  1. Connect the hybrid battery junction block assembly connector.

  1. Install the upper hybrid battery cover sub-assembly (Click here).



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (Click here)