Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P0AFC-150    Hybrid Battery Pack Sensor Module

for Preparation Click here


DESCRIPTION

The power management control ECU alerts the driver and performs fail-safe control based on error signals sent from the battery smart unit.

DTC NO.
INF Code
DTC Detection Condition
Trouble Area
P0AFC
150
Abnormal battery smart unit power source voltage
Power source voltage of the battery smart unit drops during precharge.
(1 trip detection logic)
  1. Battery smart unit
  2. Wire harness or connector
  3. Fuse
  4. Relay

Related Data List 
DTC No.
Data List
P0AFC-150
  1. Auxiliary Battery Vol (Battery smart unit power source voltage)
  2. +B

MONITOR DESCRIPTION

When the power management control ECU (HV CPU) detects a low power supply voltage for the battery smart unit while pre-charge is occurring, it determines that there is a malfunction in the battery smart unit circuit. When the power management control ECU (HV CPU) detects a malfunction, it will illuminate the MIL and set a DTC.

MONITOR STRATEGY


Related DTCs
P0AFC (INF 150): Power supply circuit malfunction
Required sensors / components
Battery smart unit
Frequency of operation
-
Duration
TMC's intellectual property
MIL operation
1 driving cycle
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the following DTCs are not present
TMC's intellectual property
Other conditions belong to TMC's intellectual property
-

TYPICAL MALFUNCTION THRESHOLDS


TMC's intellectual property
-

COMPONENT OPERATING RANGE


Power management control ECU (HV CPU)
DTC P0AFC (INF 150) is not detected

CONFIRMATION DRIVING PATTERN

  1. Connect the Techstream to the DLC3.
  2. Turn the power switch on (IG) and turn the Techstream on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  4. Turn the power switch off and wait for 30 seconds or more.
  5. Turn the power switch on (READY).
  6. Wait for 15 seconds or more.
  7. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
  8. Check that permanent DTCs are cleared.
  9. If the permanent DTCs are not cleared, perform the universal trip, and then check for permanent DTCs again.

    HINT:
    1. If a permanent DTC is output, the system is malfunctioning.
    2. If no permanent DTC is output, the system is normal.


WIRING DIAGRAM


A220462E01


INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

HINT:
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
  1. Turn the power switch on (READY) and wait for 15 seconds or more.

1.CHECK HARNESS AND CONNECTOR (IGCT VOLTAGE)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the cable from the negative (-) battery terminal.

    NOTICE:
    Check and record any DTCs, INF codes and freeze frame data, then disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).

  1. Connect the cable to the negative (-) battery terminal.

  1. Turn the power switch on (IG).



    A214447E10
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    c1-4 (IGCT) - c1-8 (GND)
    Power switch on (IG)
    11 to 14 V

    NOTICE:
    1. After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
    2. Turning the power switch on (IG) with the service plug grip removed causes an interlock switch system DTC (P0A0D-350) to be set. Use the Techstream to clear the DTCs (Click here).

    Text in Illustration 
    *a
    Component with harness connected
    (Battery Smart Unit)

  1. Turn the power switch off.

  1. Install the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).



NG
Go to step 2
OK

REPLACE BATTERY SMART UNIT (Click here)  

2.CHECK FUSE (IGCT, IGCT NO. 2)


    A315482E01
  1. Remove the IGCT and IGCT No. 2 fuses from the engine room junction block assembly.
    Text in Illustration 
    *1
    Engine Room Junction Block Assembly
    *2
    IGCT Fuse
    *3
    IGCT No. 2 Fuse

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    IGCT fuse
    Always
    Below 1 Ω
    IGCT No. 2 fuse
    Always
    Below 1 Ω

  1. Install the IGCT and IGCT No. 2 fuses to the engine room junction block assembly.



NG
REPLACE FUSE (IGCT, IGCT NO. 2)
OK


3.CHECK RELAY (IGCT)


    A315483E01
  1. Remove the IGCT relay from the engine room junction block assembly.
    Text in Illustration 
    *1
    Engine Room Junction Block Assembly
    *2
    IGCT Relay



    A111813E17
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Auxiliary battery voltage is applied between terminals 1 and 2
    10 kΩ or more
    Auxiliary battery voltage is not applied between terminals 1 and 2
    below 1 Ω

  1. Install the IGCT relay to the engine room junction block assembly.



NG
REPLACE RELAY (IGCT)
OK


4.CHECK HARNESS AND CONNECTOR (IGCT RELAY - BATTERY SMART UNIT)

CAUTION:
Be sure to wear insulated gloves.

  1. Disconnect the cable from the negative (-) battery terminal.



    A315483E01
  1. Remove the IGCT relay from the engine room junction block assembly.
    Text in Illustration 
    *1
    Engine Room Junction Block Assembly
    *2
    IGCT Relay

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).



    A217836E03
  1. Disconnect connector c1 from the battery smart unit.



    A315484E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    IGCT relay terminal 5 - c1-4 (IGCT)
    Power switch off
    Below 1 Ω

    Text in Illustration 
    *1
    Engine Room Junction Block Assembly
    *2
    IGCT relay terminal 5
    *a
    Rear view of wire harness connector
    (to Battery Smart Unit)

  1. Connect the battery smart unit connector.

  1. Install the No. 1 hybrid vehicle battery carrier bracket sub-assembly (Click here).

  1. Install the IGCT relay to the engine room junction block assembly.

  1. Connect the cable to the negative (-) battery terminal.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

CHECK AND REPAIR POWER SOURCE CIRCUIT