DTC P0A78-506 Drive Motor "A" Inverter Performance |
DTC P0A78-808 Drive Motor "A" Inverter Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A78 | 506 | Motor inverter fail signal detection (overcurrent due to hybrid vehicle transaxle assembly malfunction)* (1 trip detection logic) |
|
| P0A78 | 808 | Abnormal motor (MG2) current value detection (Hybrid vehicle transaxle assembly malfunction)* (1 trip detection logic) |
| Related DTCs | P0A78 (INF 506): MFIV detection (Over current malfunction) P0A78 (INF 808): Motor inverter abnormal current |
| Required sensors / components | Motor inverter |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | 1 driving cycle |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
| TMC's intellectual property | - |
| Power management control ECU (HV CPU) | DTC P0A78 (INF 506/808) is not detected |

| 1.CHECK DTC OUTPUT (HV) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| P0A78-202 is not output | A |
| P0A78-202 is also output | B |
Turn the power switch off.
|
| ||||
| A | |
| 2.CHECK DTC OUTPUT (HV) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| P0A78-506 or 808 only is output or DTCs except the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P0A1A (all INF codes)*1 | Generator Control Module |
| P0A1B (all INF codes)*1 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A60 (all INF codes)*1 | Drive Motor "A" Phase V Current |
| P0A63 (all INF codes)*1 | Drive Motor "A" Phase W Current |
| P0A72 (all INF codes)*1 | Generator Phase V Current |
| P0A75 (all INF codes)*1 | Generator Phase W Current |
| P0A78-266, 267, 586 | Drive Motor "A" Inverter Performance |
| P0A94-585, 587, 589, 590 | DC/DC Converter Performance |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| DTC No. | Relevant Diagnosis |
| P0A1A (all INF codes)*1 | Generator Control Module |
| P0A1B (all INF codes)*1 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A60-294 | Drive Motor "A" Phase V Current |
| P0A63-302 | Drive Motor "A" Phase W Current |
| P0A72 (all INF codes)*1 | Generator Phase V Current |
| P0A75 (all INF codes)*1 | Generator Phase W Current |
| P0A78-266, 267, 586 | Drive Motor "A" Inverter Performance |
| P0A94-585, 587, 589, 590 | DC/DC Converter Performance |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
Turn the power switch off.
|
| ||||
| A | |
| 3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
![]() |
Check that the service plug grip is not installed.
Check the connection of the low voltage connector of the inverter with converter assembly.
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER) |
Disconnect the low voltage connector D29 from the inverter with converter assembly.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D29-11 (GRF) - Body ground | Power switch on (IG) | Below 1 V |
| D29-12 (GRFG) - Body ground | Power switch on (IG) | Below 1 V |
| D29-7 (GSN) - Body ground | Power switch on (IG) | Below 1 V |
| D29-8 (GSNG) - Body ground | Power switch on (IG) | Below 1 V |
| D29-10 (GCS) - Body ground | Power switch on (IG) | Below 1 V |
| D29-9 (GCSG) - Body ground | Power switch on (IG) | Below 1 V |
| *1 | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the power switch off.
Connect the low voltage connector from the inverter with converter assembly.
|
| ||||
| OK | |
| 5.CHECK GENERATOR RESOLVER |
Disconnect the low voltage connector D29 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D29-11 (GRF) - D29-12 (GRFG) | Power switch off | 7.1 to 21.6 Ω |
| D29-7 (GSN) - D29-8 (GSNG) | Power switch off | 13.7 to 34.5 Ω |
| D29-10 (GCS) - D29-9 (GCSG) | Power switch off | 12.8 to 32.4 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| D29-11 (GRF) or D29-12 (GRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| D29-7 (GSN) or D29-8 (GSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| D29-10 (GCS) or D29-9 (GCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *1 | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 6.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER) |
Disconnect the low voltage connector D29 from the inverter with converter assembly.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D29-1 (MRF) - Body ground | Power switch on (IG) | Below 1 V |
| D29-2 (MRFG) - Body ground | Power switch on (IG) | Below 1 V |
| D29-3 (MSN) - Body ground | Power switch on (IG) | Below 1 V |
| D29-4 (MSNG) - Body ground | Power switch on (IG) | Below 1 V |
| D29-6 (MCS) - Body ground | Power switch on (IG) | Below 1 V |
| D29-5 (MCSG) - Body ground | Power switch on (IG) | Below 1 V |
| *1 | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the power switch off.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 7.CHECK MOTOR RESOLVER |
Disconnect the low voltage connector D29 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D29-1 (MRF) - D29-2 (MRFG) | Power switch off | 7.1 to 21.6 Ω |
| D29-3 (MSN) - D29-4 (MSNG) | Power switch off | 13.7 to 34.5 Ω |
| D29-6 (MCS) - D29-5 (MCSG) | Power switch off | 12.8 to 32.4 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| D29-1 (MRF) or D29-2 (MRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| D29-3 (MSN) or D29-4 (MSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| D29-6 (MCS) or D29-5 (MCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *1 | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 8.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 9.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | ||
| ||
| 10.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 11.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER) |
Disconnect the low voltage connector D29 from the inverter with converter assembly.
![]() |
Disconnect the generator resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D7-1 (GRF) - D29-11 (GRF) | Power switch off | Below 1 Ω |
| D7-5 (GRFG) - D29-12 (GRFG) | Power switch off | Below 1 Ω |
| D7-2 (GSN) - D29-7 (GSN) | Power switch off | Below 1 Ω |
| D7-6 (GSNG) - D29-8 (GSNG) | Power switch off | Below 1 Ω |
| D7-3 (GCS) - D29-10 (GCS) | Power switch off | Below 1 Ω |
| D7-7 (GCSG) - D29-9 (GCSG) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| D7-1 (GRF) or D29-11 (GRF) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| D7-5 (GRFG) or D29-12 (GRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| D7-2 (GSN) or D29-7 (GSN) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| D7-6 (GSNG) or D29-8 (GSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| D7-3 (GCS) or D29-10 (GCS) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| D7-7 (GCSG) or D29-9 (GCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *1 | Front view of wire harness connector (to Generator Resolver) |
| *2 | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the generator resolver connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||
| 12.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | |
| 13.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER) |
Disconnect the low voltage connector D29 from the inverter with converter assembly.
![]() |
Disconnect the motor resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| D1-3 (MRF) - D29-1 (MRF) | Power switch off | Below 1 Ω |
| D1-6 (MRFG) - D29-2 (MRFG) | Power switch off | Below 1 Ω |
| D1-1 (MSN) - D29-3 (MSN) | Power switch off | Below 1 Ω |
| D1-4 (MSNG) - D29-4 (MSNG) | Power switch off | Below 1 Ω |
| D1-2 (MCS) - D29-6 (MCS) | Power switch off | Below 1 Ω |
| D1-5 (MCSG) - D29-5 (MCSG) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| D1-3 (MRF) or D29-1 (MRF) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| D1-6 (MRFG) or D29-2 (MRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| D1-1 (MSN) or D29-3 (MSN) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| D1-4 (MSNG) or D29-4 (MSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| D1-2 (MCS) or D29-6 (MCS) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| D1-5 (MCSG) or D29-5 (MCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *1 | Front view of wire harness connector (to Motor Resolver) |
| *2 | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the motor resolver connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||