Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P0A7A-203    Generator Inverter Performance

for Preparation Click here


DESCRIPTION

For a description of the inverter, .

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A7A
203
Generator inverter short circuit
Current flowing to any of the phases exceeds a certain level after a DTC (indicates a generator inverter malfunction: overheating, overcurrent or circuit malfunction) is stored and the generator inverter is shutdown.
(1 trip detection logic)
  1. Inverter with converter assembly
  2. Hybrid vehicle generator assembly
  3. Generator cable

MONITOR DESCRIPTION

The MG ECU monitors the generator inverter electric current. If the current exceeds the threshold for a specified period of time, the power management control ECU (HV CPU) will illuminate the MIL and set a DTC.

MONITOR STRATEGY


Related DTCs
P0A7A (INF 203): GFIV detection (Short circuit malfunction)
Required sensors / components
Generator inverter
Frequency of operation
Continuous
Duration
TMC's intellectual property
MIL operation
1 driving cycle
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the following DTCs are not present
TMC's intellectual property
Other conditions belong to TMC's intellectual property
-

TYPICAL MALFUNCTION THRESHOLDS


TMC's intellectual property
-

COMPONENT OPERATING RANGE


Power management control ECU (HV CPU)
DTC P0A7A (INF 203) is not detected

CONFIRMATION DRIVING PATTERN


A308311E01

  1. Connect the Techstream to the DLC3.
  2. Turn the power switch on (IG) and turn the Techstream on.
  3. Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
  4. Turn the power switch off and wait for 30 seconds or more.
  5. Turn the power switch on (IG) and turn the Techstream on.
  6. Turn the power switch on (READY).
  7. With park (P) selected, wait for 5 seconds. [A]

    HINT:
    Check that there are no abnormalities (abnormal sounds, coolant leaks, DTC output, etc.)

  8. Drive the vehicle approximately 10 minutes mainly using the engine. [B]
  9. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes. [C]
  10. Read the current DTCs.

    HINT:
    1. If a current DTC is output, the system is malfunctioning.
    2. If a current DTC is not output and want to confirm permanent DTC, perform the following procedure.

  11. Check that permanent DTCs are cleared.
  12. If the permanent DTCs are not cleared, perform a universal trip, and then check for permanent DTCs again.

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
  1. DTC P0A7A-203 is stored after any of DTCs P0A7A-122, 322, 324, 325, 517 and 518 are stored. After troubleshooting and repairing DTC P0A7A-203, be sure to troubleshoot all the other DTCs.
  2. Depending on the conditions in which the vehicle is being operated when a short circuit occurs in the inverter with converter assembly, the hybrid vehicle transaxle assembly may be affected. As this DTC is stored if a short circuit occurs in the inverter with converter assembly, it is necessary to perform a road test to check the hybrid vehicle transaxle assembly. If problems are found, replace the malfunctioning parts.
  3. After completing the repair, including the repair of previously output DTCs, drive the vehicle at a speed of approximately 25 mph (40 km/h) for 1 minute and check that DTC P0A92-261 (Hybrid Generator Performance) is not output. If DTC P0A92-261 (Hybrid Generator Performance) is output, replace the hybrid vehicle generator assembly.

HINT:
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
  1. Turn the power switch on (READY) and wait for 5 seconds or more.
  2. Drive the vehicle for approximately 10 minutes mainly using the engine.

1.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A209686
  1. Remove the inverter terminal cover from the inverter with converter assembly.

  1. Disconnect the generator cable and motor cable from the inverter with converter assembly.



    A215629E02
  1. Check generator for an interphase short using a milliohmmeter.

    1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

      HINT:
      If the generator temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

      Standard Resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      f1-1 (W) - f1-2 (U)
      Power switch off
      89.5 to 98.9mΩ
      f1-2 (U) - f1-3 (V)
      Power switch off
      89.5 to 98.9mΩ
      f1-3 (V) - f1-1 (W)
      Power switch off
      89.5 to 98.9mΩ

      Text in Illustration 
      *1
      Generator Cable
      *2
      Shield Ground

      HINT:
      To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 68° F (20°C).
      1. R20 = Rt / {1 + 0.00393 X (T - 20)}
      The calculation is based on the following:
      1. R20: Resistance at 68° F (20°C) (mΩ)
      2. Rt: Measured resistance (mΩ)
      3. T: Temperature when the resistance is measured (° C)

  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    f1-1 (W) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    f1-2 (U) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    f1-3 (V) - Body ground and shield ground
    Power switch off
    100 MΩ or higher

  1. Connect the generator cable and motor cable.

  1. Install the inverter terminal cover.



NG
Go to step 3
OK


2.REPLACE INVERTER WITH CONVERTER ASSEMBLY
  1. Replace the inverter with converter assembly (Click here).



NEXT
Go to step 12

3.CHECK GENERATOR CABLE

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the generator cable.



    A217727E01
  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    f1-1 (W) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    f1-2 (U) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    f1-3 (V) - Body ground and shield ground
    Power switch off
    100 MΩ or higher

    Text in Illustration 
    *1
    Generator Cable
    (Inverter with Converter Assembly Side)
    *2
    Shield ground
    *3
    Generator Cable
    (Hybrid Vehicle Transaxle Assembly Side)

    NOTICE:
    Wrap the terminal of the three-phase AC cable with insulating tape to prevent them from coming into contact with body ground

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    f1-1 (W) - f2-3 (W)
    Power switch off
    Below 1 Ω
    f1-2 (U) - f2-2 (U)
    Power switch off
    Below 1 Ω
    f1-3 (V) - f2-1 (V)
    Power switch off
    Below 1 Ω
    f1-1 (W) - f2-2 (U)
    Power switch off
    100 MΩ or higher
    f1-2 (U) - f2-1 (V)
    Power switch off
    100 MΩ or higher
    f1-3 (V) - f2-3 (W)
    Power switch off
    100 MΩ or higher

  1. Install the generator cable.



NG
Go to step 6
OK


4.REPLACE HYBRID VEHICLE GENERATOR ASSEMBLY
  1. Replace the hybrid vehicle generator assembly (Click here).


NEXT


5.REPLACE INVERTER WITH CONVERTER ASSEMBLY
  1. Replace the inverter with converter assembly (Click here).



NEXT
Go to step 12

6.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the inverter with converter assembly.

  1. Disconnect the generator cable from the hybrid vehicle transaxle assembly.



    A217052E07
  1. Check MG1 for an interphase short using a milliohmmeter.

    1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

      HINT:
      If the MG1 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

      Standard Resistance:
      Tester Connection
      Switch Condition
      Specified Condition
      f2-2 (U) - f2-1 (V)
      Power switch off
      87.0 to 96.2 mΩ
      f2-1 (V) - f2-3 (W)
      Power switch off
      87.0 to 96.2 mΩ
      f2-3 (W) - f2-2 (U)
      Power switch off
      87.0 to 96.2 mΩ

      Text in Illustration 
      *1
      Hybrid Vehicle Transaxle Assembly

      HINT:
      To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 68°F (20°C).
      1. R20 = Rt / {1 + 0.00393 X (T - 20)}
      The calculation is based on the following:
      1. R20: Resistance at 68° F (20°C) (mΩ)
      2. Rt: Measured resistance (mΩ)
      3. T: Temperature when the resistance is measured (°C)

  1. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    f2-2 (U) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    f2-1 (V) - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    f2-3 (W) - Body ground and shield ground
    Power switch off
    100 MΩ or higher

  1. Connect the generator cable.

  1. Install the inverter with converter assembly.



NG
Go to step 9
OK


7.REPLACE GENERATOR CABLE
  1. Replace the generator cable (Click here).


NEXT


8.REPLACE INVERTER WITH CONVERTER ASSEMBLY
  1. Replace the inverter with converter assembly (Click here).



NEXT
Go to step 12

9.REPLACE GENERATOR CABLE
  1. Replace the generator cable (Click here).


NEXT


10.REPLACE HYBRID VEHICLE GENERATOR ASSEMBLY
  1. Replace the hybrid vehicle generator assembly (Click here).


NEXT


11.REPLACE INVERTER WITH CONVERTER ASSEMBLY
  1. Replace the inverter with converter assembly (Click here).


NEXT


12.CHECK DTC OUTPUT (HV)
  1. Check the other DTCs that were output together with DTC P0A7A-203.

    Result 
    DTC No.
    Relevant Diagnosis
    P0A7A-122, 322, 324, 325, 517, 518
    Generator Inverter Performance

    NOTICE:
    DTC P0A7A-203 is stored after any of DTCs P0A7A-122, 322, 324, 325, 517 and 518 are stored. After troubleshooting and repairing DTC P3245-203, be sure to troubleshoot all the other DTCs.


NEXT

GO TO DTC CHART (Click here)