SOLAR SENSOR > INSPECTION |
| 1. INSPECT SOLAR SENSOR |
![]() |
Disconnect the solar sensor connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 6 (CLTB) - 3 (CLTE) | Power switch off | Below 1 V |
| 6 (CLTB) - 3 (CLTE) | Power switch on (IG) | 11 to 14 V |
| *1 | Front view of wire harness connector (to Solar Sensor) |
![]() |
Reconnect the solar sensor connector.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 (NSHA) - 6 (CLTE) | Sensor is exposed to electric light | 0.8 to 4.3 V |
| 1 (NSHA) - 6 (CLTE) | Sensor is covered with a cloth | Below 0.8 V |
| *1 | Component with harness connected (Solar Sensor) |