DTC P3110-223 HV Main Relay |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P3110 | 223 | IGCT relay stuck on (+B short) IGCT relay is stuck on or a short to B+ exists. Power to the HV ECU does not shut down when the power switch is turned off. (1 trip detection logic) |
|

| 1.INSPECT RELAY (IGCT) |
Remove the IGCT relay from the engine room relay block and junction block assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3 - 5 | Auxiliary battery voltage is not applied between terminals 1 and 2 | 10 kΩ or higher |
Install the IGCT relay.
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY) |
Remove the IGCT relay from the engine room relay block and junction block assembly.
Disconnect connector A21 and A22 from the power management control ECU.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.

| *1 | Engine Room Relay Block and Junction Block Assembly | *2 | IGCT relay |
| *a | Rear view of wire harness connector (to Power Management Control ECU) | - | - |
| Tester Connection | Switch Condition | Specified Condition |
| A22-5 (+B1), A21-2 (+B2) or 5 (IGCT relay) - Body ground | Power switch on (IG) | Below 1 V |
Turn the power switch off.
Install the IGCT relay.
Connect the power management control ECU connector.
|
| ||||
| OK | ||
| ||