Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P3110-223    HV Main Relay

for Preparation Click here


DESCRIPTION

The power management control ECU (HV CPU) monitors the IGCT relay and detects the following malfunction.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P3110
223
IGCT relay stuck on (+B short)
IGCT relay is stuck on or a short to B+ exists. Power to the HV ECU does not shut down when the power switch is turned off.
(1 trip detection logic)
  1. Wire harness or connector
  2. IGCT relay
  3. Power management control ECU

WIRING DIAGRAM


A298778E01


INSPECTION PROCEDURE

HINT:
  1. When the circuit is shorted to +B, the battery voltage will be applied to terminal +B1 or +B2 of the power management control ECU, even though the power switch is off.
  2. After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
    1. Turn the power switch on (IG) and wait for 15 seconds or more.
    2. Turn the power switch off and wait for 30 seconds or more.

1.INSPECT RELAY (IGCT)
  1. Remove the IGCT relay from the engine room relay block and junction block assembly.



    A111813E17
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Auxiliary battery voltage is not applied between terminals 1 and 2
    10 kΩ or higher

  1. Install the IGCT relay.



NG
REPLACE RELAY (IGCT)
OK


2.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - ENGINE ROOM RELAY BLOCK AND JUNCTION BLOCK ASSEMBLY)
  1. Remove the IGCT relay from the engine room relay block and junction block assembly.

  1. Disconnect connector A21 and A22 from the power management control ECU.

  1. Turn the power switch on (IG).



  1. Measure the voltage according to the value(s) in the table below.


    A270239E02


    Text in Illustration 
    *1
    Engine Room Relay Block and Junction Block Assembly
    *2
    IGCT relay
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)
    -
    -

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A22-5 (+B1), A21-2 (+B2) or 5 (IGCT relay) - Body ground
    Power switch on (IG)
    Below 1 V

    NOTICE:
    Turning the power switch on (IG) with the connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Install the IGCT relay.

  1. Connect the power management control ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)