Home › Vehicle Interior › HEATING / AIR CONDITIONING › FRONT BLOWER MOTOR

FRONT BLOWER MOTOR > REMOVAL

for Preparation Click here



1. PRECAUTION (w/ Solar Ventilation System)

NOTICE:
Make sure to turn off the solar ventilation switch to prevent the blower motor from operating unexpectedly.



2. REMOVE NO. 2 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY


    B231119
  1. Disengage the 3 claws and guide.

  1. Disconnect each connector and remove the No. 2 instrument panel under cover sub-assembly.



3. REMOVE FRONT BLOWER MOTOR SUB-ASSEMBLY (w/o Solar Ventilation System)


    E189092
  1. Remove the quick heater connector screw.

  1. Disengage the clamp and disconnect the connector.

  1. Remove the 3 screws and front blower motor sub-assembly.

    NOTICE:
    Do not remove the front blower motor sub-assembly if it has been damaged or impacted.



4. REMOVE FRONT BLOWER MOTOR SUB-ASSEMBLY (w/ Solar Ventilation System)


    E189094
  1. Remove the quick heater connector screw.

  1. Disengage the clamp and disconnect the connector.

  1. Remove the 3 screws and front blower motor sub-assembly.

    NOTICE:
    Do not remove the front blower motor sub-assembly if it has been damaged or impacted.