EXHAUST HEAT RECIRCULATION SYSTEM > Exhaust Heat Recirculation System Circuit |

| 1.CHECK HARNESS AND CONNECTOR (ENGINE COOLANT TEMPERATURE SENSOR - NO. 3 METER CIRCUIT PLATE (COMBINATION METER)) |
Disconnect the engine coolant temperature sensor (for exhaust heat recirculation system) connector.
Disconnect the No. 3 meter circuit plate connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| G2-2 (TWS3) - L27-16 (TWS3) | Always | Below 1 Ω |
| G2-1 (E2) - L27-9 (E2) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| G2-2 (TWS3) or L27-16 (TWS3) - Body ground | Always | 10 kΩ or higher |
Reconnect the No. 3 meter circuit plate connector.
Reconnect the engine coolant temperature sensor (for exhaust heat recirculation system) connector.
|
| ||||
| OK | |
| 2.INSPECT ENGINE COOLANT TEMPERATURE SENSOR (FOR EXHAUST HEAT RECIRCULATION SYSTEM) |
Inspect the engine coolant temperature sensor (for exhaust heat recirculation system) (Click here).
|
| ||||
| OK | ||
| ||