Terminal No. (Symbol)
| Wiring Color
| Terminal Description
| Condition
| Specified Condition
|
L144-1 (+B) - L144-4 (E)
| SB - BR
| Auxiliary battery power supply
| Power switch off
| 11 to 14 V
|
L144-2 (SPI+) - L144-4 (E)
| LG - BR
| Sound signal
| Audio system is playing
| A waveform synchronized with sound is output
|
L144-3 (SPI-) - L144-4 (E)
| L - BR
| Sound signal
| Audio system is playing
| A waveform synchronized with sound is output
|
L144-4 (E) - Body ground
| BR - Body ground
| Ground
| Always
| Below 1 V
|
L144-5 (SPO+) - L144-4 (E)
| LG - BR
| Sound signal
| Audio system is playing, or Emergency call mode
| A waveform synchronized with sound is output
|
L144-6 (SPO-) - L144-4 (E)
| L - BR
| Sound signal
| Audio system is playing, or Emergency call mode
| A waveform synchronized with sound is output
|
L144-7 (IG2) - L144-4 (E)
| L - BR
| IG power supply
| Power switch on (IG)
| 11 to 14 V
|
Power switch off
| Below 1 V
|
L144-8 (ACC) - L144-4 (E)
| GR - BR
| ACC power supply
| Power switch on (ACC)
| 11 to 14 V
|
Power switch off
| Below 1 V
|
L144-9 (SLED) - L144-4 (E)
| G - BR
| Manual (SOS) switch illumination signal
| Power switch on (ACC)
| 11 to 14 V
|
Power switch off
| Below 1 V
|
L144-10 (SPDP) - L144-4 (E)
| V - BR
| Vehicle speed signal
| See "Vehicle Signal Check Mode" (Click here)
| -
|
L144-11 (IND1) - L144-4 (E)
| B - BR
| Manual (SOS) switch red indicator illumination signal
| For 2 seconds after turning the Power switch on (ACC)
| 1 to 8.5 V
|
Power switch off
| Below 1 V
|
L144-12 (IND2) - L144-4 (E)
| P - BR
| Manual (SOS) switch green indicator illumination signal
| For 2 seconds after turning the Power switch on (ACC)
| 1 to 8.5 V
|
Power switch off
| Below 1 V
|
L144-13 (BBI-)
| L
| BUB (Back-Up Battery) power supply
| -
| -
|
L144-17 (MUTE) - L144-4 (E)
| G - BR
| Mute signal
| Audio system is playing
| 3.5 V or higher
|
Emergency call mode
| Below 1 V
|
L144-18 (MCO+) - L144-4 (E)
| B - BR
| Sent microphone voice signal
| See "Microphone & Voice Recognition Check" (Click here)
| -
|
L144-19 (MCO-) - L144-4 (E)
| W - BR
| Sent microphone voice signal
| See "Microphone & Voice Recognition Check" (Click here)
| -
|
L144-20 (CTR1)
| BE
| BUB (Back-Up Battery) control line
| -
| -
|
L144-21 (CTR2)
| BR
| BUB (Back-Up Battery) control line
| -
| -
|
L144-23 (ILL+) - L144-4 (E)
| G - BR
| Illumination signal
| Light control switch off
| Below 1 V
|
Light control switch tail or ON
| 11 to 14 V
|
L144-24 (GSW) - L144-4 (E)
| R - BR
| Collision detection signal
| Power switch on (IG)
| Pulse generation (Refer to waveform 1)
|
L144-25 (SIL)
| P
| Serial communication signal
| -
| -
|
L144-26 (SIG-) - L144-4 (E)
| LG - BR
| Ground
| Always
| Below 1 V
|
L144-27 (SIG1) - L144-4 (E)
| SB - BR
| Manual (SOS) switch condition signal
| Manual (SOS) switch not pressed
| 1.5 to 2.0 V
|
Manual (SOS) switch pressed
| 0.5 to 0.8 V
|
L144-30 (BBI+)
| Y
| BUB (Back-Up Battery) power supply
| -
| -
|
L144-32 (SGND) - L144-4 (E)
| Shield - BR
| Shield ground
| Always
| Below 1 V
|
L144-33 (MCVD) - L144-4 (E)
| R - BR
| Telephone microphone assembly power supply
| Power switch off
| Below 1 V
|
Power switch on (IG)
| 4 to 6 V
|
L144-34 (MCI+) - L144-4 (E)
| B - BR
| Receive microphone voice signal
| See "Microphone & Voice Recognition Check" (Click here)
| -
|
L144-35 (MCI-) - L144-4 (E)
| W - BR
| Receive microphone voice signal
| See "Microphone & Voice Recognition Check" (Click here)
| -
|