Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P0AE7-224    Hybrid Battery Precharge Contactor Control Circuit High

for Preparation Click here


DESCRIPTION

Refer to the description for DTC P0AE6-225 .

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0AE7
224
Open or +B short in SMRP circuit
Primary circuit of SMRP is malfunctioning.
(2 trip detection logic)
  1. Wire harness or connector
  2. Hybrid battery junction block assembly
  3. Power management control ECU

Related Data List 
DTC No.
Data List
P0AE7-224
  1. VL-Voltage before Boosting
  2. VH-Voltage after Boosting
  3. Power Resource VB
  4. SMRP Status
  5. SMRB Status
  6. SMRG Status
  7. SMRP Control Status
  8. SMRB Control Status
  9. SMRG Control Status
  10. Conv Shutdown
  11. MG2 Inverter Shutdown
  12. MG1 Inverter Shutdown

WIRING DIAGRAM

Refer to the wiring diagram of DTC P0AE6-225 .

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

HINT:
  1. If DTC P0AE7-224 is output, the power switch cannot be turned on (READY).
  2. After the repair, clear the DTCs, perform the following procedure and check that the same DTC (including pending DTC) is not output.
    1. Turn the power switch off and wait for 30 seconds or more.
    2. Turn the power switch on (READY) and wait for 30 seconds or more.
    3. Turn the power switch off and wait for 60 seconds or more.

1.READ VALUE USING TECHSTREAM (SMRP STATUS)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Data List / SMRP Status.

  1. Read the Data List.

    OK:
    Tester Connection
    Switch Condition
    Specified Condition
    SMRP Status
    Power switch on (IG)
    OFF

  1. Turn the power switch off.



NG
Go to step 4
OK


2.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)


    A216617
  1. Check the connector connections and contact pressure of the relevant terminals for the power management control ECU connectors.

    OK:
    The connectors are connected securely and there are no contact pressure problems.



NG
CONNECT SECURELY
OK


3.CHECK CONNECTOR CONNECTION CONDITION (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY CONNECTOR)


    A240953
  1. Check the connector connections and contact pressure of the relevant terminals for the hybrid battery junction block assembly connector.

    OK:
    The connector is connected securely and there are no contact pressure problems.



NG
CONNECT SECURELY
OK

CHECK FOR INTERMITTENT PROBLEMS (Click here)  

4.CHECK HARNESS AND CONNECTOR (SMRP VOLTAGE)
  1. Turn the power switch on (IG).



    A243895E06
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    L5-3 (SMRP) - Body ground
    Power switch on (IG)
    Below 1 V

    Text in Illustration 
    *1
    Component with harness connected
    (Power Management Control ECU)

  1. Turn the power switch off.



NG
Go to step 6
OK


5.CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)


    A216617
  1. Check the connector connections and contact pressure of the relevant terminals for the power management control ECU connectors.

    OK:
    The connectors are connected securely and there are no contact pressure problems.



NG
CONNECT SECURELY
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)  

6.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)
  1. Disconnect connector L5 from the power management control ECU.



    A204445E09
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    L5-3 (SMRP) - Body ground
    Power switch off
    112 to 274 Ω

    Text in Illustration 
    *1
    Rear view of wire harness connector
    (to Power Management Control ECU)

  1. Connect the power management control ECU connector.



NG
Go to step 8
OK


7.CHECK HARNESS AND CONNECTOR (SHORT TO POWER SUPPLY WIRES)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A243887E01
  1. Remove the IGCT NO. 2 and AM2 fuses from the engine room relay block and junction block assembly.
    Text in Illustration 
    *1
    Engine Room Relay Block and Junction Block Assembly
    *2
    AM2 fuse
    *3
    IGCT NO. 2 fuse

  1. Remove the upper hybrid battery cover sub-assembly (Click here).

  1. Disconnect connector c3 from the hybrid battery junction block assembly.

  1. Disconnect all the connectors from the power management control ECU.



    A238662E16
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    L5-3 (SMRP) - A21-2 (+B2)
    Power switch off
    10 kΩ or higher
    L5-3 (SMRP) - A22-5 (+B1)
    Power switch off
    10 kΩ or higher
    L5-3 (SMRP) - L5-1 (AM22)
    Power switch off
    10 kΩ or higher
    L5-3 (SMRP) - L6-7 (AM21)
    Power switch off
    10 kΩ or higher
    L5-3 (SMRP) - A22-6 (MREL)
    Power switch off
    10 kΩ or higher
    L5-3 (SMRP) - A22-1 (IG2)
    Power switch off
    10 kΩ or higher
    L5-3 (SMRP) - L6-1 (ACCD)
    Power switch off
    10 kΩ or higher
    L5-3 (SMRP) - L6-2 (IG1D)
    Power switch off
    10 kΩ or higher
    L5-3 (SMRP) - A22-2 (IG2D)
    Power switch off
    10 kΩ or higher
    L5-3 (SMRP) - L5-14 (SPDI)
    Power switch off
    10 kΩ or higher
    L5-3 (SMRP) - A21-16 (GI)
    Power switch off
    10 kΩ or higher
    L5-3 (SMRP) - A21-4 (FCTL)
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *1
    Rear view of wire harness connector
    (to Power Management Control ECU)

  1. Connect the power management control ECU connectors.

  1. Connect the hybrid battery junction block assembly connector.

  1. Install the upper hybrid battery cover sub-assembly (Click here).

  1. Install the IGCT NO. 2 and AM2 fuses.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)  

8.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the upper hybrid battery cover sub-assembly (Click here).

  1. Disconnect connector c3 from the hybrid battery junction block assembly.

  1. Disconnect connector L5 from the power management control ECU.



    A213116E12
  1. Measure the resistance according to the value(s) in the table below.
    Text in Illustration 
    *1
    Rear view of wire harness connector
    (to Power Management Control ECU)
    *2
    Rear view of wire harness connector
    (to Hybrid Battery Junction Block Assembly)

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    L5-3 (SMRP) - c3-3 (SMRP)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    L5-3 (SMRP) and c3-3 (SMRP) - Body ground and other terminals
    Power switch off
    10 kΩ or higher

  1. Connect the power management control ECU connector.

  1. Connect the hybrid battery junction block assembly connector.

  1. Install the upper hybrid battery cover sub-assembly (Click here).



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


9.CHECK HARNESS AND CONNECTOR (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY - BODY GROUND)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the upper hybrid battery cover sub-assembly (Click here).

  1. Disconnect connector c3 from the hybrid battery junction block assembly.



    A209512E11
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    c3-2 (GND) - Body ground
    Power switch off
    Below 1 Ω

    Text in Illustration 
    *1
    Rear view of wire harness connector
    (to Hybrid Battery Junction Block Assembly)

  1. Connect the hybrid battery junction block assembly connector.

  1. Install the upper hybrid battery cover sub-assembly (Click here).



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


10.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the hybrid battery junction block assembly (Click here).



    A215628E40
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    c3-3 (SMRP) - c3-2 (GND)
    -40°F (-40°C) to 176°F (80 °C)
    112 to 274 Ω

    Text in Illustration 
    *1
    Hybrid Battery Junction Block Assembly

  1. Install the hybrid battery junction block assembly (Click here).



NG
REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (Click here)
OK

CHECK FOR INTERMITTENT PROBLEMS (Click here)