Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

HYBRID CONTROL SYSTEM > DATA LIST / ACTIVE TEST

for Preparation Click here



DATA LIST

NOTICE:
  1. Some Data List values may vary significantly if there are slight differences in the environment in which the vehicle is operating when measurements are obtained. Variations may also occur due to aging of the vehicle. Due to these considerations, it is not always possible to provide definite values to be used for judgment of malfunctions. It is possible that a malfunction may be present even if measured values are within the reference range.
  2. In the event of a problem with intricate symptoms, collect sample data from another vehicle of the same model operating under identical conditions in order to reach an overall judgment by comparing all the items in the Data List.

  1. Connect the Techstream to the DLC3.

  2. Turn the power switch on (IG).

  3. Enter the following menus: Powertrain / Hybrid Control / Data List.

  4. Check the results by referring to the following table.

    HINT:
    1. When reviewing Data List information, try to select only the specific Data List items related to the inspection being performed. If all items are selected when checking the Data List, the interval between updates for each item will be longer, resulting in delayed or incorrect data.
    2. Using a custom list makes it possible to easily select smaller groups of related Data List items.
    3. The following custom lists are available:
      1. Electric Leakage
      2. Boost/Lower Converter
      3. High Voltage Charge
      4. HV Transmission
      5. Thermo Sensor
      6. Auxiliary Battery
      7. Drive Performance
      8. Elec Shift Lever System


    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Engine Coolant Temp
    Engine coolant temperature/
    Min.: -40°C (-40°F), Max.: 215°C (419°F)
    Cold start→Fully warmed up:
    Gradually rises
    After warming up: 75 to 100°C (167 to 212°F)
    -
    Engine Revolution
    Engine speed/
    Min.: 0 rpm, Max.: 16383 rpm
    While idling after the engine is warmed up and inspection mode:
    Approximately 900 rpm
    While driving at a constant speed:
    No significant fluctuation
    -
    Vehicle Spd
    Vehicle speed/
    Min.: 0 km/h (0 MPH), Max.: 255 km/h (158 MPH)
    Vehicle stopped: 0 km/h (0 MPH)
    While driving at a constant speed:
    No significant fluctuation
    -
    Engine Run Time
    Elapsed time after starting engine/
    Min.: 0 s, Max.: 65535 s
    Elapsed time after starting engine
    After the power switch is turned on (READY), Elapsed time from initial engine start until the power switch is turned off.
    +B
    Auxiliary battery voltage (+B1, +B2 terminal)
    When power switch on (READY): approx. 13 to 15.5 V. When power switch on (IG): same as auxiliary battery voltage (approx. 12 V).
    If the voltage becomes 11 V or less when the power switch is on (READY), the power management control ECU stores inverter with converter assembly DTCs. If the voltage becomes 9.5 V or less, the power switch will not be able to be turned on (READY)./
    Min.: 0.00 V, Max.: 16.00 V
    Constant: 10.00 to 16.00 V
    1. Auxiliary battery condition
    2. DCDC converter
    Accel Pedal Pos #1
    Accelerator pedal position sensor No. 1 (Sensor voltage is multiplied by 20 and displayed as a percentage)/
    Min.: 0.0%, Max.: 100.0%
    Accelerator pedal depressed:
    Changes with accelerator pedal pressure
    Accelerator pedal position sensor assembly
    Accel Pedal Pos #2
    Accelerator pedal position sensor No. 2 (Sensor voltage is multiplied by 20 and displayed as a percentage)/
    Min.: 0.0%, Max.: 100.0%
    Accelerator pedal depressed:
    Changes with accelerator pedal pressure
    Accelerator pedal position sensor assembly
    Ambient Temperature
    Ambient air temperature/
    Min.: -40°C (-40°F), Max.: 215°C (419°F)
    Power switch on (IG): Same as ambient air temperature
    Ambient temperature sensor
    Intake Air Temperature
    Engine intake air temperature/
    Min.: -40°C (-40°F), Max.: 140°C (284°F)
    Constant: Almost same as ambient air temperature
    -
    DTC Clear Warm Up
    The number of times the engine is warmed up trip after clearing DTCs/
    Min.: 0, Max.: 255
    MIL OFF, engine coolant temperature increases from below 22°C (72°F) before starting the engine to above 70°C (158°F) after starting the engine: Increases once
    -
    DTC Clear Run Distance
    Drive distance after clearing DTCs/
    Min.: 0 km (0 mile), Max.: 65535 km (40723 mile)
    -
    -
    DTC Clear Min
    Elapsed time after clearing DTCs/
    Min.: 0 Min, Max.: 65535 Min
    -
    Time elapsed after DTCs are cleared (Not counted when the power switch is off)
    MIL on Engine Run Time
    Driving time after a malfunction occurs/
    Min.: 0 Min, Max.: 65535 Min
    -
    -
    MIL Status
    MIL status/
    ON or OFF
    ON: MIL ON
    Constant ON: Repair in accordance with detected DTCs
    MIL on Run Distance
    Travel distance after a malfunction occurs/
    Min.: 0 km (0 mile), Max.: 65535 km (40723 mile)
    -
    -
    Model Code
    Model code
    ZVW3#
    -
    Engine Code
    Engine code
    P410
    -
    ECU Code
    ECU code
    -
    -
    Destination
    Destination
    A
    -
    OBD Requirements
    OBD requirements
    OBD2
    -
    MAP
    Intake manifold pressure/
    Min.: 0 kPa, Max.: 255 kPa
    Power switch on (IG) or engine stopped:
    Atmospheric pressure
    Values less than atmospheric pressure are indicated while the engine is running
    Atmosphere Pressure
    Atmospheric pressure/
    Min.: 0 kPa, Max.: 255 kPa
    Constant:
    Atmospheric pressure
    -
    Number of Emission DTC
    The number of emission DTCs
    -
    -
    Ready Signal
    State of system (READY)/
    ON or OFF
    Power switch on (READY):
    ON
    -
    Motor(MG2) Revolution
    Motor (MG2) revolution speed (detected by resolver sensor) Motor (MG2) revolution speed changes in proportion to vehicle speed. Motor (MG2) revolution speed is not influenced by accelerator pedal opening angle, engine speed or generator (MG1) revolution speed./
    Min.: -32768 r/min, Max.: 32767 r/min
    While driving: Varies changes in proportion to vehicle speed.
    Hybrid vehicle transaxle assembly
    Motor(MG2) Torq
    Motor (MG2) torque request value/
    Min.: -4096.00 Nm, Max.: 4095.87 Nm
    While driving: Varies depending on vehicle operating conditions
    1. Power management control ECU
    2. Hybrid vehicle transaxle assembly
    3. Inverter with converter assembly
    M(MG2) Trq Exec Val
    Motor (MG2) torque execution value/
    Min.: -4096.00 Nm, Max.: 4095.87 Nm
    After full-load acceleration with power switch on (READY) and engine stopped: Within +/-20% of MG2 torque
    1. Power management control ECU
    2. Hybrid vehicle transaxle assembly
    3. Inverter with converter assembly
    Generator(MG1) Rev
    Generator (MG1) revolution speed (detected by resolver sensor)
    Generator (MG1) revolution speed is set to obtain requested target engine speed/
    Min.: -32768 r/min, Max.: 32767 r/min
    During charge or discharge: Varies depending on vehicle operating conditions
    1. Hybrid vehicle transaxle assembly
    2. Inverter with converter assembly
    Generator(MG1) Torq
    Generator (MG1) torque request value/
    Min.: -4096.00 Nm, Max.: 4095.87 Nm
    During charge or discharge: Varies depending on vehicle operating conditions
    1. Power management control ECU
    2. Hybrid vehicle transaxle assembly
    3. Inverter with converter assembly
    G(MG1) Trq Exec Val
    Generator (MG1) torque execution value/
    Min.: -4096.00 Nm, Max.: 4095.87 Nm
    One second after engine automatically starts with park (P) selected (Condition before engine start: Power switch on (READY), engine stopped, A/C fan speed high and headlights on):
    Within +/- 20% of MG1 torque
    1. Power management control ECU
    2. Hybrid vehicle transaxle assembly
    3. Inverter with converter assembly
    Regenerative Brake Torq
    Generator (MG1) regenerative braking execution torque/
    Min.: -4096.0 Nm, Max.: 4095.0 Nm
    While braking:
    Varies depending on vehicle operation conditions
    1. Power management control ECU
    2. Hybrid vehicle transaxle assembly
    3. Inverter with converter assembly
    Rqst Regen Brake Torq
    Requested Generator (MG1) regenerative braking torque/
    Min.: -4096.0 Nm, Max.: 4095.0 Nm
    While braking:
    Varies depending on vehicle operation conditions
    1. Power management control ECU
    2. Hybrid vehicle transaxle assembly
    3. Inverter with converter assembly
    Inverter Temp-(MG1)
    Generator inverter temperature/
    Min.: 15°C (59°F), Max.: 150°C (302°F)
    1. Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 15 to 35°C (59 to 95°F)
    2. While driving at an ambient temperature of 25°C (77°F): 15 to 110°C (59 to 230°F)
    Inverter with converter assembly
    Inverter Temp-(MG2)
    Motor inverter temperature/
    Min.: 15°C (59°F), Max.: 150°C (302°F)
    1. Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 15 to 35°C (59 to 95°F)
    2. While driving at an ambient temperature of 25°C (77°F): 15 to 110°C (59 to 230°F)
    Inverter with converter assembly
    Motor Temp No2
    Generator (MG1) temperature/
    Min.: -40°C (-40°F), Max.: 215°C (419°F)
    1. Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 25°C (77°F)
    2. While driving at an ambient temperature of 25°C (77°F): 25 to 100°C (77 to 212°F)
    GMT terminal
    Motor Temp No1
    Motor (MG2) temperature/
    Min.: -40°C (-40°F), Max.: 215°C (419°F)
    1. Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 25°C (77°F)
    2. While driving at an ambient temperature of 25°C (77°F): 25 to 90°C (77 to 194°F)
    MMT terminal
    Accelerator Degree
    Accelerator pedal depressed angle/
    Min.: 0.0%, Max.: 127.5%
    0%: Accelerator pedal released
    100%: Accelerator pedal fully depressed
    Accelerator pedal position sensor
    Request Power
    Requested engine power by power management control ECU to ECM/
    Min.: 0 W, Max.: 655350 W
    While driving with the engine running:
    Varies depending on vehicle operating conditions
    1. Power management control ECU
    2. ECM
    3. Engine
    Target Engine Rev
    Target engine speed requested by power management control ECU to ECM/
    Min.: 0 rpm, Max.: 65535 rpm
    While driving with the engine running:
    Varies depending on vehicle operating conditions
    1. Power management control ECU
    2. ECM
    3. Engine
    Engine Rev (Sensor)
    Engine speed/
    Min.: 0 rpm, Max.: 16383.75 rpm
    While idling after the engine is warmed up:
    Approximately 1000 rpm
    While driving at a constant speed:
    No significant fluctuation
    -
    State of Charge (All Bat)
    HV battery state of charge Primary calculated from charging and discharging amperage/
    Min.: 0.0%, Max.: 100.0%
    Constant:
    0.0 to 100.0%
    1. HV battery
    2. Battery smart unit
    3. Power management control ECU
    Master Cylinder Ctrl Trq
    Braking torque equivalent to master cylinder brake fluid pressure
    Total braking torque
    Master Cylinder Ctrl Trq = hydraulic brake control torque + regenerative brake torque/
    Min.: -4096.0 Nm, Max.: 4095.0 Nm
    Brake pedal depressed:
    Changes with the brake pedal pressure
    Master cylinder pressure sensor
    Power Resource VB
    HV battery voltage/
    Min.: 0.0 V, Max.: 650.0 V
    Power switch on (READY):
    168.0 to 280.0 V
    1. HV battery
    2. Battery smart unit
    3. Power management control ECU
    Power Resource IB
    HV battery current/
    Min.: -327.68 A, Max.: 327.67 A
    Power switch on (READY):
    -200.00 to 200.00 A
    1. HV battery
    2. Power cable
    3. Inverter with converter assembly
    4. Battery current sensor
    5. Air conditioning system
    Power Supply Sensor Voltage
    Power supply voltage of sensor (VC)/
    Min.: 0.00 V, Max.: 79.99 V
    Power switch on (IG):
    4.00 to 6.00 V
    -
    VL-Voltage before Boosting
    High voltage before it is boosted/
    Min.: 0 V, Max.: 450 V
    Power switch on (READY):
    Practically the same as the HV battery voltage
    1. HV battery
    2. Inverter with converter assembly
    VH-Voltage after Boosting
    High voltage after it is boosted/
    Min.: 0 V, Max.: 765 V
    Engine revving up with park (P) selected: After boosted voltage to below 650 V
    Inverter with converter assembly
    Boost Ratio
    Boost converter voltage boost ratio/
    Min.: 0.0%, Max.: 100.0%
    -
    Inverter with converter assembly
    Drive Condition ID
    Drive condition ID
    1. Engine stopped: 0
    2. Engine about to be stopped: 1
    3. Engine about to be started: 2
    4. Engine operated or operating: 3
    5. While generating or driving under load: 4
    6. Engine racing with park (P) selected: 6
    1. Power management control ECU
    2. ECM
    3. Hybrid vehicle transaxle assembly
    Shift Sensor Main
    Shift position sensor (Main) voltage/
    Min.: 0.00 V, Max.: 4.98 V
    Shift in home position or N:
    2.00 to 3.00 V
    Shift in R:
    0.30 to 1.80 V
    Shift in D or B:
    3.20 to 4.80 V
    -
    Shift Sensor Sub
    Shift position sensor (Sub) voltage/
    Min.: 0.00 V, Max.: 4.98 V
    Shift in home position or N:
    2.00 to 3.00 V
    Shift in R:
    0.30 to 1.80 V
    Shift in D or B:
    3.20 to 4.80 V
    -
    Shift Sensor Select Main
    Select position sensor (Main) voltage/
    Min.: 0.00 V, Max.: 4.98 V
    Shift in home position or B:
    1.00 to 1.60 V
    Shift in R, N or D:
    2.90 to 4.30 V
    -
    Shift Sensor Select Sub
    Select position sensor (Sub) voltage/
    Min.: 0.00 V, Max.: 4.98 V
    Shift in home position or B:
    1.00 to 1.60 V
    Shift in R, N or D:
    2.90 to 4.30 V
    -
    Shift Sensor Shift Pos
    Shift lever position/
    P/D/N/R/B
    Shift remains in one position:
    P, R, N, D or B
    Shift lever position sensor
    Crank Position
    Crankshaft position/
    Min.: -128 °CA, Max.: 127 °CA
    -
    -
    A/C Consumption Pwr
    A/C consumption power/
    Min.: 0 W, Max.: 12750 W
    While the air conditioning system is operating: 1 W to 5000 W
    1. Air conditioning system
    2. Battery smart unit
    Short Wave Highest Val
    Waveform voltage in abnormal insulation detection circuit in battery smart unit/
    Min.: 0.00 V, Max.: 4.98 V
    Left for 2 minutes in power switch on (READY), and pre-boost and post boost voltages are equal: 4.00 V or more
    High voltage circuit
    MG1 Control Mode
    Generator (MG1) control mode/
    Min.: 0, Max.: 2
    PWM: 0
    Variable PWM: 1
    Rectangular wave: 2
    -
    MG1 Carrier Frequency
    Generator (MG1) carrier frequency/
    0.75 kHz / 1.25 kHz / 2.50 kHz / 3.75 kHz / 5.00 kHz / 10.00 kHz
    -
    -
    MG2 Control Mode
    Motor (MG2) control mode/
    Min.: 0, Max.: 2
    PWM: 0
    Variable PWM: 1
    Rectangular wave: 2
    -
    MG2 Carrier Frequency
    Motor (MG2) carrier frequency/
    0.75 kHz / 1.25 kHz / 2.50 kHz / 3.75 kHz / 5.00 kHz
    -
    -
    Num of Current Code
    The number of current DTCs/
    Min.: 0, Max.: 255
    -
    -
    Num of History Code
    The number of history DTCs/
    Min.: 0, Max.: 255
    -
    -
    Check Mode
    Check Mode/
    ON or OFF
    -
    -
    Calculate Load
    Engine load/
    Min.: 0.0%, Max.: 100.0%
    1. Engine idling with warm engine, air conditioner off, park (P) and inspection mode selected: 20.0 to 40.0%
    2. Engine speed of 2500 rpm, air conditioner off, park (P) and inspection mode selected: 15.0 to 35.0%
    Throttle valve status
    Throttle Position
    Throttle position sensor/
    Min.: 0.0%, Max.: 100.0%
    Throttle valve fully closed:
    10.0 to 24.0%
    Throttle valve status
    DCDC Cnv Tar Pulse Duty
    Target auxiliary battery voltage/
    Min.: 0.0%, Max.: 100.0%
    -
    -
    Inverter Coolant Water Temperature
    Inverter coolant temperature/
    Min.: -40°C (-40°F), Max.: 110°C (230°F)
    Cold start→Fully warmed up:
    Gradually rises
    System operating normally:
    Controlled at 65°C (149°F) or less
    1. Inverter with converter assembly
    2. Inverter water pump assembly
    3. Cooling fan system
    4. Inverter cooling system
    5. IGCT NO.3 fuse
    Cooling Fan 0
    Battery cooling blower assembly operation request/
    Min.: 0.0%, Max.: 100.0%
    -
    -
    Cooling Fan Relay
    BATT FAN relay on or off/
    ON or OFF
    While the battery cooling blower assembly is operating:
    ON
    -
    Inverter W/P Revolution
    Inverter water pump assembly speed/
    Min.: 0 rpm, Max.: 15000 rpm
    Power switch on (READY):
    1375 to 5500 rpm
    When inverter water pump assembly is not operating:
    Lower than 625 rpm (625 rpm or lower is displayed even while inverter water pump assembly is stopped)
    1. Power management control ECU
    2. Inverter water pump assembly
    Prohibit DC/DC conv sig
    DC/DC converter prohibition signal/
    ON or OFF
    1. Power switch on (IG): ON (Prohibited)
    2. Power switch on (READY): OFF (Permitted)
    1. Power management control ECU
    2. DC/DC converter
    EV Request
    EV mode transition availability/
    ON or OFF
    In EV mode:
    ON
    -
    TRC OFF Switch
    VSC condition/
    OFF / TRC / TRC/VSC
    -
    -
    Starter Switch
    Starter ON / OFF status/
    ON or OFF
    Starter ON:
    ON
    -
    Inv-T (MG1) aftr IG-ON
    Generator inverter temperature soon after power switch on (IG)/
    Min.: 15°C (59°F), Max.: 150°C (302°F)
    -
    -
    Inv-T (MG2) aftr IG-ON
    Motor temperature soon after power switch on (IG)/
    Min.: 15°C (59°F), Max.: 150°C (302°F)
    -
    -
    Mtr-T (MG2) aftr IG-ON
    Motor (MG2) temperature soon after power switch on (IG)/
    Min.: -40°C (-40°F), Max.: 215°C (419°F)
    -
    -
    Conv-Tmp after IG-ON
    Boost converter temperature soon after power switch on (IG)/
    Min.: 15°C (59°F), Max.: 150°C (302°F)
    -
    -
    SOC after IG-ON
    HV battery state of charge soon after power switch on (IG)/
    Min.: 0.0%, Max.: 100.0%
    -
    -
    Inv-Temp (MG1) Max
    Maximum generator inverter temperature after power switch turned on (IG) in current trip/
    Min.: 15°C (59°F), Max.: 150°C (302°F)
    -
    -
    Inv-Temp (MG2) Max
    Maximum motor inverter temperature after power switch turned on (IG) in current trip/
    Min.: 15°C (59°F), Max.: 150°C (302°F)
    -
    -
    Mtr-Temp (MG2) Max
    Maximum motor (MG2) temperature after power switch turned on (IG) in current trip/
    Min.: -40°C (-40°F), Max.: 215°C (419°F)
    -
    -
    Converter Temp Max
    Maximum converter temperature after power switch turned on (IG) in current trip/
    Min.: 15°C (59°F), Max.: 150°C (302°F)
    -
    -
    Status of Charge Max
    Maximum SOC after power switch turned on (IG) in current trip/
    Min.: 0.0%, Max.: 100.0%
    -
    -
    Status of Charge Min
    Minimum SOC after power switch turned on (IG) in current trip/
    Min.: 0.0%, Max.: 127.5%
    -
    -
    Stop Light Switch
    Stop light switch condition/
    ON or OFF
    Brake pedal depressed:
    ON
    -
    Auxiliary Batt Temperature
    Auxiliary battery temperature/
    Min.: -40°C (-40°F), Max.: 215°C (419°F)
    Auxiliary battery temperature is 20°C (68°F):
    When ambient air temperature is 20°C (68°F)
    -
    Collision Signal (Airbag)
    Detection of collision by airbag ECU assembly/
    ON or OFF
    Collision detection by the airbag ECU assembly:
    ON
    -
    TC Terminal
    TC terminal state/
    ON or OFF
    TC terminal connected:
    ON
    -
    Inter Lock Switch
    Interlock switch condition/
    ON or OFF
    Power switch on (IG), inverter cover, high voltage input cables or service plug grip not installed.
    ON
    -
    EV Switch
    EV drive mode switch (integration control and panel sub-assembly) condition/
    ON or OFF
    -
    -
    Back Up Lamp Relay
    Back up light switch condition/
    ON or OFF
    Shift position (R) selected
    ON
    -
    ECO Mode
    ECO mode signal/
    ON or OFF
    ECO mode being selected OFF→ON:
    OFF→ON
    1. Combination meter assembly
    2. Power management control ECU
    Generate Torque
    Generated drive torque/
    Min.: -4096.0 Nm, Max.: 4095.8 Nm
    While driving: Varies depending on vehicle operating conditions
    -
    Prohibit Charge for P Pos
    HV battery charge in park (P) selected prohibition state/
    ON or OFF
    HV battery charge in park (P) selected prohibition:
    ON
    -
    Vehicle Parking (T/M Ctrl)
    Indicates whether vehicle being driven or stopped./
    ON or OFF
    -
    -
    Shift Pos Status (T/M Ctrl)
    Indicates whether park (P) is selected/
    Not P / Run / P
    -
    -
    Shift P Permission Signal
    Indicates whether selection of park (P) is permitted./
    ON or OFF
    -
    -
    DC/DC Cnv Temp (Upper)
    Boost converter temperature (upper)/
    Min.: 15°C (59°F), Max.: 150°C (302°F)
    1. Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 15 to 35°C (59 to 95°F)
    2. While driving at an ambient temperature of 25°C (77°F): 15 to 110°C (59 to 230°F)
    Inverter with converter assembly
    Safing Signal (Airbag)
    Safing state of the airbag ECU assembly/
    ON or OFF
    When safing state of the airbag ECU assembly:
    ON
    -
    DC/DC Cnv Temp (Lower)
    Boost converter temperature (lower)/
    Min.: 15°C (59°F), Max.: 150°C (302°F)
    1. Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 15 to 35°C (59 to 95°F)
    2. While driving at an ambient temperature of 25°C (77°F): 15 to 121°C (59 to 250°F)
    Inverter with converter assembly
    Normal Signal for A/B ECU
    Control state of airbag ECU assembly/
    ON or OFF
    When the airbag ECU assembly is operating normally:
    ON
    -
    Mtr-T (MG1) aftr IG-ON
    Generator (MG1) temperature soon after power switch on (IG)/
    Min.: -40°C (-40°F), Max.: 215°C (419°F)
    -
    -
    Mtr-Temp (MG1) Max
    Maximum generator (MG1) temperature after power switch turned on (IG) in current trip/
    Min.: -40°C (-40°F), Max.: 215°C (419°F)
    -
    -
    Overvoltage Input to Conv
    Overvoltage detection into boost converter/
    ON or OFF
    Overvoltage is detected into boost converter:
    ON
    -
    Overvoltage Input to Inv
    Overvoltage detection into inverter/
    ON or OFF
    Overvoltage is detected into inverter:
    ON
    -
    Emergency Shutdown
    Inverter emergency shutdown/
    ON or OFF
    Inverter emergency shutdown (HSDN signal ON):
    ON
    -
    MG1 Inverter Shutdown
    Generator inverter shutdown/
    ON or OFF
    Generator inverter shutdown:
    ON
    -
    MG1 Inverter Fail
    Generator inverter stopped/
    ON or OFF
    Generator inverter stopped:
    ON
    -
    MG2 Inverter Shutdown
    Motor inverter shutdown/
    ON or OFF
    Motor inverter shutdown:
    ON
    -
    MG2 Inverter Fail
    Motor inverter stopped/
    ON or OFF
    Motor inverter stopped:
    ON
    -
    Conv Shutdown
    Boost converter shutdown/
    ON or OFF
    Boost converter shutdown:
    ON
    -
    Converter Fail
    Boost converter stopped/
    ON or OFF
    Boost converter stopped:
    ON
    -
    P Pos SW Terminal Vol
    Indicates voltage at the P position switch terminals/
    Min.: 0.00 V, Max.: 4.98 V
    P position switch ON:
    0.00 to 1.50 V
    -
    Internal Shift Position
    ECU internal shift condition/
    P/R/N/D/B
    Matches currently selected condition:
    P, R, N, D or B
    -
    P Rq Malfunction (T/M Ctrl)
    Indicates whether park (P) selection request is normal/
    Normal or Abnormal
    -
    -
    P Request (T/M Ctrl)
    Indicates whether selection of park (P) is requested./
    ON or OFF
    -
    -
    T/M Control ECU Status
    Indicates the control condition of the transmission control ECU/
    Normal or Abnormal
    -
    -
    T/M ECU Pulse Consec Err
    Indicates consecutive communication errors with the transmission control ECU/
    Normal or Abnormal
    -
    -
    T/M ECU Pulse Single Err
    Indicates a single communication error with the transmission control ECU/
    Normal or Abnormal
    -
    -
    HV Start Condition
    Indicates the hybrid start condition/
    Norml / Pr A/C / Remote
    -
    -
    W/P Run Control Duty
    Inverter water pump motor driver request duty/
    Min.: 0.00%, Max.: 100.00%
    Power switch on (READY):
    62.50 to 81.25%
    Power management control ECU
    Engine Stop Request
    Engine stop request/
    ON or OFF
    Requesting engine stop:
    ON
    1. ECM
    2. Power management control ECU
    Engine Idling Request
    Engine idling request/
    ON or OFF
    Requesting idle:
    ON
    1. ECM
    2. Power management control ECU
    Main Batt Charging Rqst
    Engine idling request to charge HV battery/
    ON or OFF
    Requesting HV battery charging:
    ON
    1. Battery smart unit
    2. HV battery
    Aircon Request
    Engine idling request from air conditioning amplifier assembly/
    ON or OFF
    While an engine start is requested from the air conditioning amplifier assembly:
    ON
    Air conditioning amplifier
    Engine Warming Up Rqst
    Engine idling request to warm up engine/
    ON or OFF
    While an engine warm-up is requested:
    ON
    After the engine is warmed up:
    OFF
    1. Power management control ECU
    2. ECM
    SMRP Status
    Operating state of SMRP (primary circuit monitor)/
    ON or OFF
    Immediately after the power switch on (ST-ON) state occurred:
    ON
    After the above timing:
    OFF
    1. Hybrid battery junction block assembly
    2. Wire harness
    3. Power management control ECU
    SMRB Status
    Operating state of SMRB (primary circuit monitor)/
    ON or OFF
    Power switch on (READY):
    ON
    1. Hybrid battery junction block assembly
    2. Wire harness
    3. Power management control ECU
    SMRG Status
    Operating state of SMRG (primary circuit monitor)/
    ON or OFF
    Power switch on (READY):
    ON
    1. Hybrid battery junction block assembly
    2. Wire harness
    3. Power management control ECU
    SMRP Control Status
    Control state of SMRP/
    ON or OFF
    Immediately after the power switch on (ST-ON) state occurred:
    ON
    After the above timing:
    OFF
    -
    SMRB Control Status
    Control state of SMRB/
    ON or OFF
    Power switch on (READY):
    ON
    -
    SMRG Control Status
    Control state of SMRG/
    ON or OFF
    Power switch on (READY):
    ON
    -
    MG1 Gate Status
    Generator (MG1) gate status/
    ON or OFF
    Shutting down generator inverter:
    ON
    1. Power management control ECU
    2. Inverter with converter assembly
    MG2 Gate Status
    Motor (MG2) gate status/
    ON or OFF
    Shutting down motor inverter:
    ON
    1. Power management control ECU
    2. Inverter with converter assembly
    Converter Gate Status
    Boost converter gate status/
    ON or OFF
    Shutting down boost converter:
    ON
    1. Power management control ECU
    2. Inverter with converter assembly
    Aircon Gate Status
    While A/C inverter is being shut off/
    ON or OFF
    While A/C inverter is being shut off:
    ON
    1. Air conditioning amplifier
    2. Power management control ECU
    Converter Carrier Freq
    Converter signal carrier frequency/
    9.55 kHz / 9.13 kHz / 8.71 kHz / 8.29 kHz / 7.87 kHz / 7.45 kHz / 4.8 kHz
    -
    -
    Delta SOC
    Difference between maximum and minimum values of each block SOC/
    Min.: 0.0%, Max.: 100.0%
    READY indicator on, engine stopped and no electrical load:
    0.0 to 60.0%
    -
    Batt Pack Current Val
    HV battery current/
    1. Discharging amperage is indicated with positive values
    2. Charging amperage is indicated with negative values
    Min.: -327.68 A, Max.: 327.67 A
    Immediately after starting a full-load acceleration with the engine stopped:
    Maximum 190.00 A
    Immediately after engine start with park (P) selected:
    May be 100.00 A or more
    HV battery current sensor circuit
    Inhaling Air Temp
    HV battery intake air temperature/
    Min.: -50.0°C (-58.0°F), Max.: 205.9°C (402.6°F)
    Same as ambient air temperature:
    Vehicle left for one day
    -
    VMF Fan Motor Voltage1
    Battery blower motor monitoring voltage/
    Min.: 0.0 V, Max.: 25.5 V
    Fan mode 1 with READY indicator ON and park (P) selected:
    1.0 to 1.4 V
    Battery cooling fan circuit
    Auxiliary Battery Vol
    Auxiliary battery voltage (Battery smart unit power source voltage)/
    Min.: 0.00 V, Max.: 16.00 V
    Same as auxiliary battery voltage (power switch on (IG))
    1. Auxiliary battery
    2. DC/DC converter
    Charge Control Value
    Charge control wattage sent from battery smart unit to power management control ECU/
    Min.: -64.0 kW, Max.: 63.5 kW
    -33.0 kW or more
    -
    Discharge Control Value
    Discharge control wattage sent from battery smart unit to power management control ECU/
    Min.: -64.0 kW, Max.: 63.5 kW
    30.0 kW or less
    -
    Cooling Fan Mode1
    Battery cooling blower assembly operation mode/
    Min.: 0, Max.: 255
    Power switch on (IG) or on (READY), and cooling fan stopped:
    0
    Power switch on (IG) or on (READY), and cooling fan low speed to high speed:
    1→6
    Battery cooling fan circuit
    ECU Control Mode
    HV battery control mode/
    Min.: 1, Max.: 5
    Driving control mode:
    1
    Current sensor offset mode:
    2
    External charge control mode:
    3
    Power supply end mode:
    4
    -
    Standby Blower Request
    Battery blower motor stop control request (standby blower)/
    ON or OFF
    ON or OFF
    Air conditioning system (To ensure cabin cooling performance)
    Temp of Batt TB1
    HV battery module temperature/
    Min.: -50.0°C (-58.0°F), Max.: 205.9°C (402.6°F)
    Undisturbed for 1 day:
    Same as ambient air temperature
    1. Battery temperature sensor
    2. Battery smart unit
    Temp of Batt TB2
    HV battery module temperature/
    Min.: -50.0°C (-58.0°F), Max.: 205.9°C (402.6°F)
    Undisturbed for 1 day:
    Same as ambient air temperature
    1. Battery temperature sensor
    2. Battery smart unit
    Temp of Batt TB3
    HV battery module temperature/
    Min.: -50.0°C (-58.0°F), Max.: 205.9°C (402.6°F)
    Undisturbed for 1 day:
    Same as ambient air temperature
    1. Battery temperature sensor
    2. Battery smart unit
    Battery Block Num
    The number of HV battery blocks
    Always: 14
    HV battery
    Batt Block Minimum Vol
    The lowest voltage among the HV battery blocks/
    Min.: 0.00 V, Max.: 79.99 V
    SOC 55 to 60%: 12.00 V or more
    -
    Minimum Batt Block No
    Battery block number with minimum voltage/
    Min.: 0, Max.: 14
    Any of block number 0 to 14
    -
    Batt Block Max Vol
    The highest voltage among the HV battery blocks/
    Min.: 0.00 V, Max.: 79.99 V
    SOC 55 to 60%: 23.00 V or less
    -
    Max Battery Block No
    Battery block number with maximum voltage/
    Min.: 0, Max.: 14
    Any of block number 0 to 14
    -
    Battery Block Vol -V01
    Battery block voltage/
    Min.: 0.00 V, Max.: 79.99 V
    SOC 60% : 12.00 to 20.00 V
    1. HV battery
    2. Battery smart unit
    Battery Block Vol -V02
    Battery block voltage/
    Min.: 0.00 V, Max.: 79.99 V
    SOC 60% : 12.00 to 20.00 V
    1. HV battery
    2. Battery smart unit
    Battery Block Vol -V03
    Battery block voltage/
    Min.: 0.00 V, Max.: 79.99 V
    SOC 60% : 12.00 to 20.00 V
    1. HV battery
    2. Battery smart unit
    Battery Block Vol -V04
    Battery block voltage/
    Min.: 0.00 V, Max.: 79.99 V
    SOC 60% : 12.00 to 20.00 V
    1. HV battery
    2. Battery smart unit
    Battery Block Vol -V05
    Battery block voltage/
    Min.: 0.00 V, Max.: 79.99 V
    SOC 60% : 12.00 to 20.00 V
    1. HV battery
    2. Battery smart unit
    Battery Block Vol -V06
    Battery block voltage/
    Min.: 0.00 V, Max.: 79.99 V
    SOC 60% : 12.00 to 20.00 V
    1. HV battery
    2. Battery smart unit
    Battery Block Vol -V07
    Battery block voltage/
    Min.: 0.00 V, Max.: 79.99 V
    SOC 60% : 12.00 to 20.00 V
    1. HV battery
    2. Battery smart unit
    Battery Block Vol -V08
    Battery block voltage/
    Min.: 0.00 V, Max.: 79.99 V
    SOC 60% : 12.00 to 20.00 V
    1. HV battery
    2. Battery smart unit
    Battery Block Vol -V09
    Battery block voltage/
    Min.: 0.00 V, Max.: 79.99 V
    SOC 60% : 12.00 to 20.00 V
    1. HV battery
    2. Battery smart unit
    Battery Block Vol -V10
    Battery block voltage/
    Min.: 0.00 V, Max.: 79.99 V
    SOC 60% : 12.00 to 20.00 V
    1. HV battery
    2. Battery smart unit
    Battery Block Vol -V11
    Battery block voltage/
    Min.: 0.00 V, Max.: 79.99 V
    SOC 60% : 12.00 to 20.00 V
    1. HV battery
    2. Battery smart unit
    Battery Block Vol -V12
    Battery block voltage/
    Min.: 0.00 V, Max.: 79.99 V
    SOC 60% : 12.00 to 20.00 V
    1. HV battery
    2. Battery smart unit
    Battery Block Vol -V13
    Battery block voltage/
    Min.: 0.00 V, Max.: 79.99 V
    SOC 60% : 12.00 to 20.00 V
    1. HV battery
    2. Battery smart unit
    Battery Block Vol -V14
    Battery block voltage/
    Min.: 0.00 V, Max.: 79.99 V
    SOC 60% : 12.00 to 20.00 V
    1. HV battery
    2. Battery smart unit
    Internal Resistance R01
    Internal resistance of each battery block/
    Min.: 0.000 Ω, Max.: 0.255 Ω
    Always:
    0.010 to 0.100 Ω
    HV battery
    Internal Resistance R02
    Internal resistance of each battery block/
    Min.: 0.000 Ω, Max.: 0.255 Ω
    Always:
    0.010 to 0.100 Ω
    HV battery
    Internal Resistance R03
    Internal resistance of each battery block/
    Min.: 0.000 Ω, Max.: 0.255 Ω
    Always:
    0.010 to 0.100 Ω
    HV battery
    Internal Resistance R04
    Internal resistance of each battery block/
    Min.: 0.000 Ω, Max.: 0.255 Ω
    Always:
    0.010 to 0.100 Ω
    HV battery
    Internal Resistance R05
    Internal resistance of each battery block/
    Min.: 0.000 Ω, Max.: 0.255 Ω
    Always:
    0.010 to 0.100 Ω
    HV battery
    Internal Resistance R06
    Internal resistance of each battery block/
    Min.: 0.000 Ω, Max.: 0.255 Ω
    Always:
    0.010 to 0.100 Ω
    HV battery
    Internal Resistance R07
    Internal resistance of each battery block/
    Min.: 0.000 Ω, Max.: 0.255 Ω
    Always:
    0.010 to 0.100 Ω
    HV battery
    Internal Resistance R08
    Internal resistance of each battery block/
    Min.: 0.000 Ω, Max.: 0.255 Ω
    Always:
    0.010 to 0.100 Ω
    HV battery
    Internal Resistance R09
    Internal resistance of each battery block/
    Min.: 0.000 Ω, Max.: 0.255 Ω
    Always:
    0.010 to 0.100 Ω
    HV battery
    Internal Resistance R10
    Internal resistance of each battery block/
    Min.: 0.000 Ω, Max.: 0.255 Ω
    Always:
    0.010 to 0.100 Ω
    HV battery
    Internal Resistance R11
    Internal resistance of each battery block/
    Min.: 0.000 Ω, Max.: 0.255 Ω
    Always:
    0.010 to 0.100 Ω
    HV battery
    Internal Resistance R12
    Internal resistance of each battery block/
    Min.: 0.000 Ω, Max.: 0.255 Ω
    Always:
    0.010 to 0.100 Ω
    HV battery
    Internal Resistance R13
    Internal resistance of each battery block/
    Min.: 0.000 Ω, Max.: 0.255 Ω
    Always:
    0.010 to 0.100 Ω
    HV battery
    Internal Resistance R14
    Internal resistance of each battery block/
    Min.: 0.000 Ω, Max.: 0.255 Ω
    Always:
    0.010 to 0.100 Ω
    HV battery
    Battery Low Time
    Number of cumulative times any battery block voltage dropped excessively/
    Min.: 0, Max.: 65535
    -
    -
    DC Inhibit Time
    Number of cumulative times SOC of HV battery dropped excessively and discharge was prohibited/
    Min.: 0, Max.: 65535
    -
    -
    Battery too High Time
    Number of cumulative times SOC of HV battery was high and charging was prohibited/
    Min.: 0, Max.: 65535
    -
    -
    Hot Temperature Time
    Number of cumulative times HV battery temperature became high/
    Min.: 0, Max.: 65535
    -
    -
    Pattern Switch (PWR/M)
    POWER mode switch (integration control and panel sub-assembly) signal/
    ON or OFF
    POWER mode switch (integration control and panel sub-assembly) on:
    ON
    -


ACTIVE TEST
Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data list information can be displayed while performing Active Tests.

NOTICE:
  1. It is necessary to use caution, because if the tester DLC connector becomes disconnected or if a communication error occurs during an Active Test, the vehicle could become inoperative (the READY indicator may go off).
  2. After performing the Active Test, turn the power switch off before proceeding to the next step.

  1. Connect the Techstream to the DLC3.

  2. Turn the power switch on (IG).

  3. Turn the Techstream on.
    Enter the following menus: Powertrain / Hybrid Control / Active Test.

  4. According to the display on the Techstream perform the appropriate Active Test.

    Tester Display
    Test Part
    Control Range
    Test Details
    Test Condition
    Inspection Mode -2WD Inspection*1
    -
    -
    -
    -
    Inspection Mode -2WD Chassis-Dynamo*1
    -
    -
    -
    -
    Compression Test*2
    To crank the engine continuously in order to measure the compression
    ON / OFF
    Allows the engine to continue cranking by activating generator (MG1) continuously
    Power switch on (IG), HV system normal (non of related DTCs), not in cranking mode, and other Active Tests not being done
    Activate the Water Pump
    1. To activate the inverter water pump assembly continuously
    2. Before performing the Active Test of the inverter water pump with motor assembly, check the coolant level.
      Related Data List
      1. W/P Run Control Duty
      2. Inverter W/P Revolution
      3. Inverter Coolant Water Temperature
      4. +B
    ON / OFF
    Activates the inverter water pump assembly assembly continuously
    Power switch on (IG), HV system normal (non of related DTCs), not in inspection mode, and auxiliary battery voltage is more than 9.5 V or more
    Driving the Battery Cooling Fan
    1. Activate the cooling fan or changes air volume mode
    2. If the value of a cooling fan drive request from the vehicle is larger than that used for the Active Test, Active Test is prohibited (remains prohibited during the same trip).
      Related Data List
      1. Cooling Fan Mode1
      2. Cooling Fan 0
      3. +B
      4. Temp of Batt TB1 to TB3
      5. Inhaling Air Temp
    1 to 6
    To check operation of the cooling fan, and check if there is sufficient air flow
    Power switch on (IG)
    Connect the TC and TE1
    Batch display of warnings on combination meter
    ON / OFF
    TC terminal can be switched ON/OFF
    Power switch on (IG), system is normal

    NOTICE:
    1. *1: Enter inspection mode (Click here).
    2. *2: The Techstream will display a communication error and the vehicle's READY indicator will turn off when the Active Test is completed. If the Techstream will be used on the vehicle again, turn the power switch off and then on (READY) again to restart the Techstream.