Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

HYBRID CONTROL SYSTEM > INFORMATION / FREEZE FRAME DATA

for Preparation Click here



FREEZE FRAME DATA

HINT:
The power management control ECU records vehicle and driving condition information as freeze frame data the moment a DTC is stored. It can be used for estimating or duplicating the vehicle conditions that were present when the malfunction occurred. To confirm the details of the hybrid control system, check the detailed information for the DTC information code in the Data List (INF code).

  1. Connect the Techstream to the DLC3.

  2. Turn the power switch on (IG).

  3. Turn the Techstream on.

  4. Enter the following menus: Powertrain / Hybrid Control / DTC.

  5. Select a DTC in order to display its freeze frame data.

  6. Check the freeze frame information recorded with the DTC.

    FREEZE FRAME DATA 
    Tester Display
    Measurement Item/Range
    Suspected Vehicle Status When Malfunction Occurs
    Engine Coolant Temp
    1. Engine coolant temperature/
    2. Min.: -40°C (-40°F), Max.: 215°C (419°F)
    Cold or warmed-up engine
    Engine Revolution
    1. Engine speed/
    2. Min.: 0 rpm, Max.: 16383.75 rpm
    Engine speed
    Vehicle Spd
    1. Vehicle speed/
    2. Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph)
    Stopped, or driving (at low, medium, or high speeds)
    Engine Run Time
    1. Elapsed time after engine start/
    2. Min.: 0 s, Max.: 65535 s
    After the power switch is turned on (READY), elapsed time from initial engine start until the power switch is turned off.
    +B
    1. Auxiliary battery voltage/
    2. Min.: 0.00 V, Max.: 16.00 V
    Auxiliary battery and DC/DC converter condition
    Accel Pedal Pos #1
    1. Accelerator pedal position sensor No. 1/
    2. Min.: 0.0%, Max.: 100.0%
    Idling, accelerating, or decelerating
    Accel Pedal Pos #2
    1. Accelerator pedal position sensor No. 2/
    2. Min.: 0.0%, Max.: 100.0%
    For comparison to accelerator pedal position sensor No. 1
    Ambient Temperature
    1. Ambient air temperature/
    2. Min.: -40°C (-40°F), Max.: 215°CF (419°)
    -
    Intake Air Temperature
    1. Engine intake air temperature/
    2. Min.: -40°C (-40°F), Max.: 140°C (284°F)
    -
    DTC Clear Warm Up
    1. The number of times the trip of engine is warmed up after clearing DTCs/
    2. Min.: 0, Max.: 255
    -
    DTC Clear Run Distance
    1. Drive distance after clearing DTCs/
    2. Min.: 0 km (0 mile), Max.: 65535 km (40723 mile)
    -
    DTC Clear Min
    1. Elapsed time after clearing DTCs (without IG off time)/
    2. Min.: 0 min, Max.: 65535 min
    -
    MIL on Engine Run Time
    1. Driving time after a malfunction occurs/
    2. Min.: 0 min, Max.: 65535 min
    -
    MIL Status
    1. MIL Status/
    2. ON or OFF
    Constant ON: Repair in accordance with detected DTCs
    MIL on Run Distance
    1. Travel distance after a malfunction occurs/
    2. Min.: 0 km (0 mile), Max.: 65535 km (40723 mile)
    -
    OBD Requirements
    1. OBD requirements
    -
    MAP
    1. Intake manifold pressure/
    2. Min.: 0 kPa, Max.: 255 kPa
    -
    Atmosphere Pressure
    1. Atmospheric pressure/
    2. Min.: 0 kPa, Max.: 255 kPa
    Altitude of the driving environment
    Number of Emission DTC
    1. The number of emission DTCs
    -
    Ready Signal
    1. State of system (READY)
    2. ON or OFF
    -
    Motor(MG2) Revolution
    1. Motor (MG2) revolution/
    2. Min.: -32768 rpm, Max.: 32767 rpm
    -
    Motor(MG2) Torq
    1. Motor (MG2) torque request value/
    2. Min.: -4096.00 Nm, Max.: 4095.87 Nm
    -
    M(MG2) Trq Exec Val
    1. Motor (MG2) torque execution value/
    2. Min.: -4096.00 Nm, Max.: 4095.87 Nm
    -
    Generator(MG1) Rev
    1. Generator (MG1) revolution/
    2. Min.: -32768 r/min, Max.: 32767 r/min
    -
    Generator(MG1) Torq
    1. Generator (MG1) torque request value/
    2. Min.: -4096.00 Nm, Max.: 4095.87 Nm
    -
    G(MG1) Trq Exec Val
    1. Generator (MG1) torque execution value/
    2. Min.: -4096.00 Nm, Max.: 4095.87 Nm
    -
    Regenerative Brake Torq
    1. Generator (MG1) regenerative braking execution torque/
    2. Min.: -4096.0 Nm, Max.: 4095.0 Nm
    -
    Rqst Regen Brake Torq
    1. Requested generator (MG1) regenerative braking torque/
    2. Min.: -4096.0 Nm, Max.: 4095.0 Nm
    -
    Inverter Temp-(MG1)
    1. Generator inverter temperature/
    2. Min.: 15°C (59°F), Max.: 150°C (302°F)
    -
    Inverter Temp-(MG2)
    1. Motor inverter temperature/
    2. Min.: 15°C (59°F), Max.: 150°C (302°F)
    -
    Motor Temp No2
    1. Generator (MG1) temperature/
    2. Min.: -40°C (-40°F), Max.: 215°C (419°F)
    -
    Motor Temp No1
    1. Motor (MG2) temperature/
    2. Min.: -40°C (-40°F), Max.: 215°C (419°F)
    -
    Accelerator Degree
    1. Accelerator pedal depressed angle/
    2. Min.: 0.0%, Max.: 100.0%
    -
    Request Power
    1. Request engine power/
    2. Min.: 0 W, Max.: 655350 W
    -
    Target Engine Rev
    1. Target engine speed/
    2. Min.: 0 rpm, Max.: 65535 rpm
    -
    Engine Rev (Sensor)
    1. Engine speed/
    2. Min.: 0 rpm, Max.: 16383 rpm
    -
    State of Charge (All Bat)
    1. HV battery state of charge/
    2. Min.: 0.0%, Max.: 100.0%
    State of charge of HV battery
    Master Cylinder Ctrl Trq
    1. Braking torque equivalent to master cylinder brake fluid pressure/
    2. Min.: -4096.0 Nm, Max.: 4095.0 Nm
    Brake force requested by driver
    Power Resource VB
    1. HV battery voltage/
    2. Min.: 0.0 V, Max.: 650.0 V
    HV battery condition
    Power Resource IB
    1. HV battery charge/discharge status/
    2. Min.: -327.68 A, Max.:327.67 A
    HV battery condition
    Power Supply Sensor Voltage
    1. Power supply sensor voltage (VC)/
    2. Min.: 0.00 V, Max.: 79.99 V
    -
    VL-Voltage before Boosting
    1. High voltage before it is boosted/
    2. Min.: 0.0 V, Max.: 450.0 V
    -
    VH-Voltage after Boosting
    1. High voltage after it is boosted/
    2. Min.: 0.0 V, Max.: 765.0 V
    -
    Boost Ratio
    1. Boost converter voltage boost ratio/
    2. Min.: 0.0%, Max.: 100.0%
    -
    Drive Condition ID
    Drive condition ID/
    1. Engine stopped: 0
    2. Engine about to be stopped: 1
    3. Engine about to be started: 2
    4. Engine operated or operating: 3
    5. While generating or driving under load: 4
    6. Engine racing with park (P) selected: 6
    Engine operating condition
    Shift Sensor Main
    1. Shift position sensor (Main) voltage/
    2. Min.: 0.00 V, Max.: 4.98 V
    -
    Shift Sensor Sub
    1. Shift position sensor (Sub) voltage/
    2. Min.: 0.00 V, Max.: 4.98 V
    -
    Shift Sensor Select Main
    1. Select position sensor (Main) voltage/
    2. Min.: 0.00 V, Max.: 4.98 V
    -
    Shift Sensor Select Sub
    1. Select position sensor (Sub) voltage/
    2. Min.: 0.00 V, Max.: 4.98 V
    -
    Shift Sensor Shift Pos
    1. Shift lever position/
    2. R/N/D/B
    Selected shift position
    Crank Position
    1. Crankshaft position/
    2. Min.: -128 °CA, Max.: 127 °CA
    -
    A/C Consumption Pwr
    1. A/C consumption power/
    2. Min.: 0 W, Max.: 12750 W
    -
    Short Wave Highest Val
    1. Waveform voltage in abnormal insulation detection circuit in battery smart unit/
    2. Min.: 0.00 V, Max.: 4.98 V
    Indicates that insulation resistance has decreased
    MG1 Control Mode
    1. Generator (MG1) control mode/
    2. PWM: 0/Variable PWM: 1/Rectangular wave: 2
    Operating state of inverter with converter assembly
    MG1 Carrier Frequency
    1. Generator (MG1) carrier frequency/
    2. 0.75 kHz/1.25 kHz/2.50 kHz/3.75 kHz/5.00 kHz/10.00 kHz
    -
    MG2 Control Mode
    1. Motor (MG2) control mode/
    2. PWM: 0/Variable PWM: 1/Rectangular wave: 2
    Operating state of inverter with converter assembly
    MG2 Carrier Frequency
    1. Motor (MG2) carrier frequency/
    2. 0.75 kHz/1.25 kHz/2.50 kHz/3.75 kHz/5.00 kHz
    -
    Num of Current Code
    1. The number of current DTCs/
    2. Min.: 0, Max.: 255
    -
    Num of History Code
    1. The number of history DTCs/
    2. Min.: 0, Max.: 255
    -
    Calculate Load
    1. Calculated load/
    2. Min.: 0.0%, Max.: 100.0%
    -
    Throttle Position
    1. Throttle position sensor/
    2. Min.: 0.0%, Max.: 100.0%
    -
    DCDC Cnv Tar Pulse Duty
    1. Target auxiliary battery voltage/
    2. Min.: 0.0%, Max.: 399.9%
    -
    Inverter Coolant Water Temperature
    1. Inverter coolant temperature/
    2. Min.: -40°C (-40°F), Max.: 110°C (230°F)
    -
    Cooling Fan 0
    1. Cooling fan operating condition/
    2. Min.: 0.0%, Max.: 100.0%
    -
    Cooling Fan Relay
    1. BATT FAN relay/
    2. ON or OFF
    Cooling fan operating condition
    Inverter W/P Revolution
    1. Inverter water pump assembly speed/
    2. Min.: 0 rpm, Max.: 15000 rpm
    Operating state of inverter water pump assembly
    Prohibit DC/DC conv sig
    1. DC/DC converter prohibition signal/
    2. ON or OFF
    -
    EV Request
    1. EV mode transition availability/
    2. ON or OFF
    EV mode on or off
    TRC OFF Switch
    1. TRC OFF switch condition/
    2. OFF/TRC/TRC,VSC
    VSC OFF switch on or off
    Starter Switch
    1. Starter ON/OFF status/
    2. OFF or ON
    -
    Inv-T (MG1) aftr IG-ON
    1. Generator inverter temperature soon after power switch on (IG)/
    2. Min.: 15°C (59°F), Max.: 150°C (302°F)
    -
    Inv-T (MG2) aftr IG-ON
    1. Motor inverter temperature soon after power switch on (IG)/
    2. Min.: 15°C (59°F), Max.: 150°C (302°F)
    -
    Mtr-T (MG2) aftr IG-ON
    1. Motor (MG2) temperature soon after power switch on (IG)/
    2. Min.: -40°C (-40°F), Max.: 215°C (419°F)
    -
    Conv-Tmp after IG-ON
    1. Boost converter temperature soon after power switch on (IG)/
    2. Min.: 15°C (59°F), Max.: 150°C (302°F)
    -
    SOC after IG-ON
    1. HV battery state of charge soon after power switch on (IG)/
    2. Min.: 0.0%, Max.: 127.5%
    HV battery condition
    Inv-Temp (MG1) Max
    1. Maximum generator inverter temperature soon after power switch turned on (IG) in current trip/
    2. Min.: 15°C (59°F), Max.: 150°C (302°F)
    -
    Inv-Temp (MG2) Max
    1. Maximum motor inverter temperature after power switch turned on (IG) in current trip/
    2. Min.: 15°C (59°F), Max.: 150°C (302°F)
    -
    Mtr-Temp (MG2) Max
    1. Maximum motor (MG2) temperature after power switch turned on (IG) in current trip/
    2. Min.: -40°C (-40°F), Max.: 215°C (419°F)
    -
    Converter Temp Max
    1. Maximum converter temperature after power switch turned on (IG) in current trip/
    2. Min.: 15°C (59°F), Max.: 150°C (302°F)
    -
    Status of Charge Max
    1. Maximum SOC after power switch turned on (IG) in current trip/
    2. Min.: 0.0%, Max.: 100.0%
    HV battery condition
    Status of Charge Min
    1. Minimum SOC after power switch turned on (IG) in current trip/
    2. Min.: 0.0%, Max.: 100.0%
    HV battery condition
    Stop Light Switch
    1. Stop light switch condition/
    2. ON or OFF
    Brake pedal depressed
    Auxiliary Batt Temperature
    1. Auxiliary battery temperature/
    2. Min.: -40°C (-40°F), Max.: 215°C (419°F)
    -
    Collision Signal (Airbag)
    1. Detection of collision by airbag ECU assembly/
    2. ON or OFF
    Operating state of airbag ECU assembly
    TC Terminal
    1. TC terminal state/
    2. ON or OFF
    -
    Inter Lock Switch
    1. Interlock switch condition/
    2. ON or OFF
    Power switch on (IG), inverter cover, high-voltage input cables or service plug grip not installed: ON
    EV Switch
    1. EV drive mode switch (integration control and panel sub-assembly) condition/
    2. ON or OFF
    -
    Back Up Lamp Relay
    1. Back up light switch condition/
    2. ON or OFF
    Shift position (R) selected: ON
    ECO Mode
    1. ECO drive mode signal/
    2. ON or OFF
    ECO mode on or off
    Generate Torque
    1. Generated drive torque/
    2. Min.: -4096.0 Nm, Max.: 4095.8 Nm
    -
    Prohibit Charge for P Pos
    1. HV battery charge in park (P) prohibition state/
    2. ON or OFF
    -
    Vehicle Parking (T/M Ctrl)
    1. Indicates whether vehicle being driven or stopped./
    2. ON or OFF
    -
    Shift Pos Status (T/M Ctrl)
    1. Indicates whether park (P) is selected/
    2. Not P/Run/P
    -
    Shift P Permission Signal
    1. Indicates whether selection of park (P) is permitted/
    2. ON or OFF
    -
    DC/DC Cnv Temp (Upper)
    1. Boost converter temperature (upper)/
    2. Min.: 15°C (59°F), Max.: 150°C (302°F)
    -
    Safing Signal (Airbag)
    1. Safing state of the airbag ECU assembly/
    2. ON or OFF
    Operating state of airbag ECU assembly
    DC/DC Cnv Temp (Lower)
    1. Boost converter temperature (lower)/
    2. Min.: 15°C (59°F), Max.: 150°C (302°F)
    -
    Normal Signal for A/B ECU
    1. Control state of airbag ECU assembly/
    2. Normal or Abnormal
    Operating state of airbag ECU assembly
    Mtr-T (MG1) aftr IG-ON
    1. Generator (MG1) temperature soon after power switch on (IG)/
    2. Min.: -40°C (-40°F), Max.: 215°C (419°F)
    -
    Mtr-Temp (MG1) Max
    1. Maximum generator (MG1) temperature after power switch turned on (IG) in current trip/
    2. Min.: -40°C (-40°F), Max.: 215°C (419°F)
    -
    Overvoltage Input to Conv
    1. Boost converter overvoltage detection/
    2. ON or OFF
    -
    Overvoltage Input to Inv
    1. Inverter overvoltage detection/
    2. ON or OFF
    -
    Emergency Shutdown
    1. Inverter emergency shutdown/
    2. ON or OFF
    Operating state of inverter with converter assembly
    MG1 Inverter Shutdown
    1. Generator inverter shutdown/
    2. ON or OFF
    Operating state of inverter with converter assembly
    MG1 Inverter Fail
    1. Generator inverter failure/
    2. ON or OFF
    Operating state of inverter with converter assembly
    MG2 Inverter Shutdown
    1. Motor inverter shutdown/
    2. ON or OFF
    Operating state of inverter with converter assembly
    MG2 Inverter Fail
    1. Motor inverter failure/
    2. ON or OFF
    Operating state of inverter with converter assembly
    Conv Shutdown
    1. Converter shutdown/
    2. ON or OFF
    Operating state of inverter with converter assembly
    Converter Fail
    1. Boost converter failure/
    2. ON or OFF
    Operating state of inverter with converter assembly
    P Pos SW Terminal Vol
    1. Indicates voltage at the P position switch terminal/
    2. Min.: 0.00 V, Max.: 4.98 V
    -
    Internal Shift Position
    1. ECU internal shift condition/
    2. R/N/D/B
    Shift lever position
    P Rq Malfunction (T/M Ctrl)
    1. Indicates whether park (P) selection request is normal/
    2. Normal or Abnormal
    -
    P Request (T/M Ctrl)
    1. Indicates whether selection of park (P) is requested/
    2. ON or OFF
    -
    T/M Control ECU Status
    1. Indicates the control condition of the transmission control ECU/
    2. Normal or Abnormal
    -
    T/M ECU Pulse Consec Err
    1. Indicates consecutive communication errors with the transmission control ECU/
    2. Normal or Abnormal
    -
    T/M ECU Pulse Single Err
    1. Indicates a single communication error with the transmission control ECU/
    2. Normal or Abnormal
    -
    HV Start Condition
    1. Indicates the hybrid start condition/
    2. Norml / Pr A/C / Remote
    -
    W/P Run Control Duty
    1. Inverter water pump assembly motor drive request duty/
    2. Min.: 0%, Max.: 100%
    Operating state of inverter water pump assembly
    Engine Stop Request
    1. Engine stop request/
    2. ON or OFF
    Engine operating conditions
    Engine Idling Request
    1. Engine idling request/
    2. ON or OFF
    Engine operating conditions
    Main Batt Charging Rqst
    1. Engine idling request to charge HV battery/
    2. ON or OFF
    HV battery condition
    Aircon Request
    1. Engine idling request from air conditioning amplifier assembly/
    2. ON or OFF
    -
    Engine Warming Up Rqst
    1. Engine idling request to warm up engine/
    2. NO or YES
    Engine operating conditions
    SMRP Status
    1. Operating state of SMRP (primary circuit monitor)/
    2. ON or OFF control
    -
    SMRB Status
    1. Operating state of SMRB (primary circuit monitor)/
    2. ON or OFF
    -
    SMRG Status
    1. Operating state of SMRG (primary circuit monitor)/
    2. ON or OFF
    -
    SMRP Control Status
    1. Instructing control state of SMRP/
    2. ON or OFF
    -
    SMRB Control Status
    1. Instructing control state of SMRB/
    2. ON or OFF
    -
    SMRG Control Status
    1. Instructing control state of SMRG/
    2. ON or OFF
    -
    MG1 Gate Status
    1. Generator (MG1) Gate Status/
    2. ON or OFF
    Operating state of inverter with converter assembly
    MG2 Gate Status
    1. Motor (MG2) Gate Status/
    2. ON or OFF
    Operating state of inverter with converter assembly
    Converter Gate Status
    1. Boost converter gate status/
    2. ON or OFF
    Operating state of inverter with converter assembly
    Aircon Gate Status
    1. While A/C inverter a being shut off/
    2. ON or OFF
    -
    Converter Carrier Freq
    1. Boost converter signal carrier frequency/
    2. 9.55 kHz/9.13 kHz/8.71 kHz/8.29 kHz/7.87 kHz/7.45 kHz/ 4.8 kHz
    -
    Delta SOC
    1. Difference between maximum and minimum values of each block SOC/
    2. Min.: 0.0%, Max.: 100.0%
    SOC variance
    Batt Pack Current Val
    1. HV battery current/
    2. Min.: -327.68 A, Max.: 327.67 A
    HV battery charge/discharge status
    1. Amount of current during discharge is displayed with positive values
    2. Amount of current during charge is displayed with negative values
    Inhaling Air Temp
    1. HV battery intake air temperature/
    2. Min.: -50.0°C (-58.0°F), Max.: 205.9°C (402.6°F)
    -
    VMF Fan Motor Voltage1
    1. Cooling fan monitor voltage/
    2. Min.: 0.0 V, Max.: 25.5 V
    Operating state of cooling fan
    Auxiliary Battery Vol
    1. Auxiliary battery voltage (Battery smart unit power source voltage)/
    2. Min.: 0.00 V, Max.: 16.00V
    Auxiliary battery and DC/DC converter condition
    Charge Control Value
    1. Charge control wattage sent from battery smart unit to power management control ECU/
    2. Min.: -64.0 kW, Max.: 63.5 kW
    Charge amount of HV battery
    Discharge Control Value
    1. Discharge control wattage sent from battery smart unit to power management control ECU/
    2. Min.: -64.0 kW, Max.: 63.5 kW
    Discharge amount of HV battery
    Cooling Fan Mode1
    1. Battery cooling blower assembly operation mode/
    2. Min.: 0, Max.: 6
    HV battery cooling fan activation condition
    1. Cooling fan stopped: 0
    2. Low speed drive - high speed drive: 1-6
    ECU Control Mode
    1. HV battery control mode/
    2. Min.: 1, Max.: 4
    HV battery control status
    Standby Blower Request
    1. Battery cooling fan Lo speed requested/
    2. ON or OFF
    Operating state of cooling fan
    Temp of Batt TB1
    1. Battery module temperature/
    2. Min.: -50.0°C (-58.0°F), Max.: 205.9°C (402.6°F)
    HV battery temperature
    Temp of Batt TB2
    1. Battery module temperature/
    2. Min.: -50.0°C (-58.0°F), Max.: 205.9°C (402.6°F)
    HV battery temperature
    Temp of Batt TB3
    1. Battery module temperature/
    2. Min.: -50.0°C (-58.0°F), Max.: 205.9°C (402.6°F)
    HV battery temperature
    Battery Block Vol -V01
    1. Battery block voltage/
    2. Min.: 0.00 V, Max.: 79.99 V
    Each HV battery block voltage variance
    Battery Block Vol -V02
    1. Battery block voltage/
    2. Min.: 0.00 V, Max.: 79.99 V
    Each HV battery block voltage variance
    Battery Block Vol -V03
    1. Battery block voltage/
    2. Min.: 0.00 V, Max.: 79.99 V
    Each HV battery block voltage variance
    Battery Block Vol -V04
    1. Battery block voltage/
    2. Min.: 0.00 V, Max.: 79.99 V
    Each HV battery block voltage variance
    Battery Block Vol -V05
    1. Battery block voltage/
    2. Min.: 0.00 V, Max.: 79.99 V
    Each HV battery block voltage variance
    Battery Block Vol -V06
    1. Battery block voltage/
    2. Min.: 0.00 V, Max.: 79.99 V
    Each HV battery block voltage variance
    Battery Block Vol -V07
    1. Battery block voltage/
    2. Min.: 0.00 V, Max.: 79.99 V
    Each HV battery block voltage variance
    Battery Block Vol -V08
    1. Battery block voltage/
    2. Min.: 0.00 V, Max.: 79.99 V
    Each HV battery block voltage variance
    Battery Block Vol -V09
    1. Battery block voltage/
    2. Min.: 0.00 V, Max.: 79.99 V
    Each HV battery block voltage variance
    Battery Block Vol -V10
    1. Battery block voltage/
    2. Min.: 0.00 V, Max.: 79.99 V
    Each HV battery block voltage variance
    Battery Block Vol -V11
    1. Battery block voltage/
    2. Min.: 0.00 V, Max.: 79.99 V
    Each HV battery block voltage variance
    Battery Block Vol -V12
    1. Battery block voltage/
    2. Min.: 0.00 V, Max.: 79.99 V
    Each HV battery block voltage variance
    Battery Block Vol -V13
    1. Battery block voltage/
    2. Min.: 0.00 V, Max.: 79.99 V
    Each HV battery block voltage variance
    Battery Block Vol -V14
    1. Battery block voltage/
    2. Min.: 0.00 V, Max.: 79.99 V
    Each HV battery block voltage variance
    Pattern Switch (PWR/M)
    1. POWER mode switch (integration control and panel sub-assembly) signal/
    2. ON or OFF
    -
    Detail Code 1
    1. Number of detailed information stored by information code/
    2. Min.: 0, Max.: 32767
    -
    Detail Code 2
    1. Number of detailed information stored by information code/
    2. Min.: 0, Max.: 32767
    -
    Detail Code 3
    1. Number of detailed information stored by information code/
    2. Min.: 0, Max.: 32767
    -
    Detail Code 4
    1. Number of detailed information stored by information code/
    2. Min.: 0, Max.: 32767
    -
    Detail Code 5
    1. Number of detailed information stored by information code/
    2. Min.: 0, Max.: 32767
    -


INFORMATION

HINT:
Similar to freeze frame data, the power management control ECU also records vehicle and driving condition information as INFORMATION (INF code) at the moment a DTC is stored.

  1. Select the information item which has an INF code from among Information 1 to 5.

  2. Check the information for the DTC.

    INFORMATION  
    Tester Display
    Measurement Item/Range
    Suspected Vehicle Status When Malfunction Occurs
    Information 1 to 5
    INF code
    Identification of malfunctioning system
    Generator(MG1) Rev
    1. Generator (MG1) revolution/
    2. Min.: -16384 rpm, Max.: 16256 rpm
    Generator (MG1) speed
    1. Forward rotation appears as "+"
    2. Backward rotation appears as "-"
    Motor(MG2) Revolution
    1. Motor (MG2) revolution/
    2. Min.: -16384 rpm, Max.: 16256 rpm
    Motor (MG2) speed
    1. When vehicle go forward appears as "+"
    2. When vehicle go backward appears as "-"
    Generator(MG1) Torq
    1. Generator (MG1) torque/
    2. Min.: -512 Nm, Max.: 508 Nm
    When generator (MG1) rotates in "+" direction:
    1. Torque appears as "+" while generator (MG1) discharges
    2. Torque appears as "-" while generator (MG1) charges
    When generator (MG1) rotates in "-" direction:
    1. Torque appears as "-" while generator (MG1) discharges
    2. Torque appears as "+" while generator (MG1) charges
    Motor(MG2) Torq
    1. Motor (MG2) torque/
    2. Min.: -512 Nm, Max.: 508 Nm
    When motor (MG2) rotates in "+" direction:
    1. Torque appears as "+" while motor (MG2) discharges
    2. Torque appears as "-" while motor (MG2) charges
    When motor (MG2) rotates in "-" direction:
    1. Torque appears as "-" while motor (MG2) discharges
    2. Torque appears as "+" while motor (MG2) charges
    Request Power
    1. Request engine power/
    2. Min.: 0 kW, Max.: 255 kW
    Engine power output requested to ECM
    Engine Spd
    1. Engine speed/
    2. Min.: 0 rpm, Max.: 16320 rpm
    Engine speed
    Master Cylinder Ctrl Trq
    1. Master cylinder control torque/
    2. Min.: -512 Nm, Max.: 508 Nm
    Brake force requested by driver
    State of Charge
    1. HV battery state of charge/
    2. Min.: 0.0%, Max.: 100.0%
    Charge of amount HV battery
    WOUT Control Power
    1. Power value discharge limiting control/
    2. Min.: 0 W, Max.: 81600 W
    Discharge amount of HV battery
    WIN Control Power
    1. Power value charge limiting control/
    2. Min.: -40800 W, Max.: 0 W
    Charge amount of HV battery
    Drive Condition ID
    Drive condition ID/
    1. Engine stopped: 0
    2. Engine about to be stopped: 1
    3. Engine about to be started: 2
    4. Engine operated or operating: 3
    5. While generating or driving under load: 4
    6. Engine racing with park (P) selected: 6
    Engine operating condition
    Power Resource VB
    1. HV battery voltage/
    2. Min.: 0 V, Max.: 510 V
    HV battery voltage
    Power Resource IB
    1. HV battery charge/discharge status/
    2. Min.: -256 A, Max.: 254 A
    HV battery charge and discharge current
    1. Amount of current during discharge is indicated with positive values
    2. Amount of current during charge is indicated with negative values
    Shift Sensor Shift Pos
    1. Shift lever position/
    2. P/R/N/D/B
    Shift lever position sensor
    Auxiliary Batt Voltage
    1. Auxiliary battery voltage and battery smart unit power source voltage/
    2. Min.: 0.00 V, Max.: 16.00 V
    Auxiliary battery and DCDC converter condition
    VL-Voltage before Boosting
    1. High voltage before it is boosted/
    2. Min.: 0 V, Max.: 450 V
    High voltage level before it is boosted
    VH-Voltage after Boosting
    1. High voltage after it is boosted/
    2. Min.: 0 V, Max.: 765 V
    High voltage level after it is boosted
    The Time of Ignition ON
    1. Elapsed time after power switch on (IG)/
    2. Min.: 0 min, Max.: 255 min
    Time elapsed with power switch on (IG)
    Vehicle Speed(Max)
    1. Maximum vehicle speed/
    2. Min.: -256 km/h (-159 mph), Max.: 254 km/h (157 mph)
    Maximum vehicle speed
    Engine Stop Request
    1. Engine stop request/
    2. No or Yes
    Engine stop request
    Engine Idling Request
    1. Engine idling request/
    2. No or Yes
    Idle stop request
    Engine Fuel Cut
    1. Engine fuel cut/
    2. No or Yes
    Fuel cut
    Main Batt Charging Rqst
    1. HV battery charging request/
    2. No or Yes
    Engine idling request to charge HV battery
    Engine Warming Up Rqst
    1. Engine warming up request/
    2. No or Yes
    Engine idling request to warm up engine
    Stop Switch
    1. Stop light switch ON condition/
    2. No or Yes
    Brake pedal depressed or released
    Exclusive Information 1
    1. Indicates exclusive information/
    2. Min.: -127, Max.: 127
    Exclusive information linked to Information
    Exclusive Information 2
    1. Indicates exclusive information/
    2. Min.: -127, Max.: 127
    Exclusive information linked to Information
    Exclusive Information 3
    1. Indicates exclusive information/
    2. Min.: -127, Max.: 127
    Exclusive information linked to Information
    Exclusive Information 4
    1. Indicates exclusive information/
    2. Min.: -127, Max.: 127
    Exclusive information linked to Information
    Exclusive Information 5
    1. Indicates exclusive information/
    2. Min.: -127, Max.: 127
    Exclusive information linked to Information
    Exclusive Information 6
    1. Indicates exclusive information/
    2. Min.: -127, Max.: 127
    Exclusive information linked to Information
    Exclusive Information 7
    1. Indicates exclusive information/
    2. Min.: -127, Max.: 127
    Exclusive information linked to Information
    Occurrence Order
    Occurrence sequence of information
    Occurrence sequence of information
    Cnv Tmp (Upper)
    1. Boost converter temperature (upper)/
    2. Min.: 15°C (59°F), Max.: 150°C (302°F)
    Boost converter temperature
    Cnv Temp (Lower)
    1. Boost converter temperature (lower)/
    2. Min.: 15°C (59°F), Max.: 150°C (302°F)
    Boost converter temperature
    Generator Temp
    1. Generator (MG1) temperature/
    2. Min.: -40°C (-40°F), Max.: 215°C (419°F)
    Generator (MG1) temperature
    MG1 Carrier Frequency
    1. Generator (MG1) Carrier Frequency/
    2. 0.75 kHz / 1.25 kHz / 2.50 kHz / 3.75 kHz / 5.00 kHz / 10.00 kHz
    Generator (MG1) inverter carrier frequency
    MG2 Carrier Frequency
    1. Motor (MG2) carrier frequency/
    2. 0.75 kHz / 1.25 kHz / 2.50 kHz / 3.75 kHz / 5.00 kHz
    Motor (MG2) inverter carrier frequency
    Motor Temp
    1. Motor (MG2) temperature/
    2. Min.: -40°C (-40°F), Max.: 215°C (419°F)
    Motor (MG2) carrier temperature
    Converter Carrier Freq
    1. Converter carrier frequency/
    2. 9.55 kHz / 9.13 kHz / 8.71 kHz / 8.29 kHz / 7.87 kHz / 7.45 kHz / 4.8 kHz
    Converter carrier frequency
    Inverter Temp (MG1)
    1. Generator inverter temperature/
    2. Min.: 15°C (59°F), Max.: 150°C (302°F)
    Generator inverter temperature
    MG1 Control Mode
    1. Generator (MG1) control mode/
    2. PWM: 0/Variable PWM: 1/Rectangular wave: 2
    Generator (MG1) control mode
    Inverter Temp (MG2)
    1. Motor inverter temperature/
    2. Min.: 15°C (59°F), Max.: 150°C (302°F)
    Motor inverter temperature
    MG2 Control Mode
    1. Motor (MG2) control mode/
    2. PWM: 0/Variable PWM: 1/Rectangular wave: 2
    Motor (MG2) control mode
    Boost Ratio
    1. Boost ratio/
    2. Min.: 0.0%, Max.: 100.0%
    Boost condition
    MG1 Inverter Shutdown
    1. Generator inverter shutdown/
    2. ON or OFF
    Generator inverter shutdown: ON
    HV Coolant Temperature
    1. HV coolant temperature/
    2. Min.: -40°C (-40°F), Max.: 110°C (230°F)
    HV coolant temperature
    MG2 Inverter Shutdown
    1. Motor inverter shutdown/
    2. ON or OFF
    Motor inverter shutdown: ON
    Accel Sensor Main
    1. Accelerator pedal depressed angle/
    2. Min.: 0.0%, Max.: 100.0%
    Idling, accelerating, or decelerating
    Conv Shutdown
    1. DC/DC converter shutdown/
    2. ON or OFF
    DC/DC converter shutdown: ON