Home › Vehicle Exterior › LIGHTING (EXT) › LIGHTING SYSTEM

LIGHTING SYSTEM > FAIL-SAFE CHART

for Preparation Click here



LED HEADLIGHT SYSTEM
The light control ECU operates in fail-safe mode if an abnormal condition such as those listed below has been detected.

Item
Abnormality Detection Condition
Return Condition
Master Warning Light
Multi-information Display
Abnormal input voltage (High input voltage)
Abnormal power source voltage (more than 17 V) is detected.
Normal power source voltage (10 to 16 V) is detected.
Flashes
CHECK HEADLIGHT SYSTEM
Abnormal input voltage (Low input voltage)*1
If the power source voltage is too low (8.5 to 10 V), LED output current will be limited. (Headlights will remain illuminated.)
Output current limit is canceled when the voltage returns to the specified operation voltage (10 to 16 V).
Flashes
CHECK HEADLIGHT SYSTEM
If the power source voltage is too low (7.1 to 8.5 V), headlight operation will stop.
If the voltage returns to 8.5 V or more, headlight operation will resume.
Abnormal output
  1. Open in output side circuit
  2. Short between output terminal and body ground
Light control switch is turned off to head.
Flashes
CHECK HEADLIGHT SYSTEM
  1. *1: When the headlights are on and the input voltage becomes between 6 and 10 V, the headlights dim.