Home › Vehicle Interior › DOOR LOCK › POWER DOOR LOCK CONTROL SYSTEM

POWER DOOR LOCK CONTROL SYSTEM > All Doors LOCK/UNLOCK Functions do not Operate Via Door Control Switch or Door Key Cylinder

for Preparation Click here


DESCRIPTION

The main body ECU (multiplex network body ECU) receives switch signals from the door control switch (power window regulator master switch assembly) and driver door key cylinder lock or unlock switch signals from the front door lock assembly LH*1 or front door lock assembly RH*2. The main body ECU (multiplex network body ECU) activates the door lock motor on each door according to these signals.
  1. *1: for LHD
  2. *2: for RHD

WIRING DIAGRAM


B296423E09


INSPECTION PROCEDURE

1.CHECK DOOR LOCK OPERATION
  1. Check door lock operation (Click here).

    Result:
    Result
    Proceed to
    All doors cannot be locked through door control switch (power window regulator master switch assembly)
    A
    All doors cannot be locked through driver door key cylinder
    B



B
Go to step 5
A


2.READ VALUE USING INTELLIGENT TESTER (DOOR CONTROL SWITCH (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY))
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Turn the intelligent tester on.

  1. Enter the following menus: Body / Main Body / Data List.

  1. Read the Data List according to the display on the intelligent tester.

    Main Body (Main Body ECU (Multiplex Network Body ECU)) 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Door Lock SW-Lock
    Door control switch (power window regulator master switch assembly) lock signal/ON or OFF
    ON: Lock side of door control switch (power window regulator master switch assembly) pushed
    OFF: Lock side of door control switch (power window regulator master switch assembly) not pushed
    -
    Door Lock SW-Unlock
    Door control switch (power window regulator master switch assembly) unlock signal/ON or OFF
    ON: Unlock side of door control switch (power window regulator master switch assembly) pushed
    OFF: Unlock side of door control switch (power window regulator master switch assembly) not pushed
    -

    OK:
    The intelligent tester indicates ON or OFF according to the switch operation shown in the table above.



NG
Go to step 3
OK

REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) (Click here)  

3.INSPECT DOOR CONTROL SWITCH (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY)


  1. for LHD



      B302422E07
    1. Remove the door control switch (power window regulator master switch assembly) (Click here).

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      2 (L) - 1 (E)
      Lock switch pushed
      Below 1 Ω
      2 (L) - 1 (E)
      Lock switch not pushed
      10 kΩ or higher
      9 (UL) - 1 (E)
      Unlock switch pushed
      Below 1 Ω
      9 (UL) - 1 (E)
      Unlock switch pushed
      10 kΩ or higher

      Text in Illustration 
      *a
      Component without harness connected
      (Door Control Switch (Power Window Regulator Master Switch Assembly))



  1. for RHD



      B302422E19
    1. Remove the door control switch (power window regulator master switch assembly) (Click here).

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      2 (L) - 9 (E)
      Lock switch pushed
      Below 1 Ω
      2 (L) - 9 (E)
      Lock switch not pushed
      10 kΩ or higher
      8 (UL) - 9 (E)
      Unlock switch pushed
      Below 1 Ω
      8 (UL) - 9 (E)
      Unlock switch pushed
      10 kΩ or higher

      Text in Illustration 
      *a
      Component without harness connected
      (Door Control Switch (Power Window Regulator Master Switch Assembly))



NG
REPLACE POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY
OK


4.CHECK HARNESS AND CONNECTOR (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))
  1. Disconnect the G59 main body ECU (multiplex network body ECU) connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    J1-2 (L) - G59-9 (L1)
    Always
    Below 1 Ω
    J1-9 (UL) - G59-10 (UL1)
    Always
    Below 1 Ω
    J1-1 (E) - Body ground
    Always
    Below 1 Ω
    J1-2 (L) - Body ground
    Always
    10 kΩ or higher
    J1-9 (UL) - Body ground
    Always
    10 kΩ or higher
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    H1-2 (L) - G59-9 (L1)
    Always
    Below 1 Ω
    H1-8 (UL) - G59-10 (UL1)
    Always
    Below 1 Ω
    H1-9 (E) - Body ground
    Always
    Below 1 Ω
    H1-2 (L) - Body ground
    Always
    10 kΩ or higher
    H1-8 (UL) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) (Click here)  

5.READ VALUE USING INTELLIGENT TESTER (DOOR KEY-LINKED LOCK AND UNLOCK SWITCH)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Turn the intelligent tester on.

  1. Enter the following menus: Body / Main Body / Data List.

  1. Read the Data List according to the display on the intelligent tester.

    Main Body (Main Body ECU (Multiplex Network Body ECU)) 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Door Key SW-Lock
    Driver door key-linked lock/unlock switch lock signal/ON or OFF
    ON: Driver door key cylinder turned to lock position
    OFF: Driver door key cylinder not turned to lock position
    -
    Door Key SW-Unlock
    Driver door key-linked lock/unlock switch unlock signal/ON or OFF
    ON: Driver door key cylinder turned to unlock position
    OFF: Driver door key cylinder not turned to unlock position
    -

    OK:
    The intelligent tester indicates ON or OFF according to the key cylinder operation shown in the table.



NG
Go to step 6
OK

REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) (Click here)  

6.INSPECT FRONT DOOR LOCK ASSEMBLY


  1. for LHD

    1. Remove the front door lock assembly LH (Click here).



    2. B280166E03
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      9 (L) - 7 (E)
      Turned to lock
      Below 1 Ω
      9 (L) - 7 (E)
      Not turned
      10 kΩ or higher
      10 (UL) - 7 (E)
      Turned to unlock
      Below 1 Ω
      10 (UL) - 7 (E)
      Not turned
      10 kΩ or higher

      Text in Illustration 
      *a
      Component without harness connected
      (Front Door Lock Assembly LH)
      *b
      Unlock
      *c
      Lock



  1. for RHD

    1. Remove the front door lock assembly RH (Click here).



    2. B280267E07
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      6 (L) - 8 (E)
      Turned to lock
      Below 1 Ω
      6 (L) - 8 (E)
      Not turned
      10 kΩ or higher
      5 (UL) - 8 (E)
      Turned to unlock
      Below 1 Ω
      5 (UL) - 8 (E)
      Not turned
      10 kΩ or higher

      Text in Illustration 
      *a
      Component without harness connected
      (Front Door Lock Assembly RH)
      *b
      Unlock
      *c
      Lock



NG
REPLACE FRONT DOOR LOCK ASSEMBLY LH (Click here)
OK


7.CHECK HARNESS AND CONNECTOR (FRONT DOOR LOCK ASSEMBLY - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))
  1. Disconnect the G59 main body ECU (multiplex network body ECU) connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    J6-9 (L) - G59-11 (L2)
    Always
    Below 1 Ω
    J6-10 (UL) - G59-12 (UL2)
    Always
    Below 1 Ω
    J6-7 (E) - Body ground
    Always
    Below 1 Ω
    G59-11 (L2) - Body ground
    Always
    10 kΩ or higher
    G59-12 (UL2) - Body ground
    Always
    10 kΩ or higher
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    H6-6 (L) - G59-11 (L2)
    Always
    Below 1 Ω
    H6-5 (UL) - G59-12 (UL2)
    Always
    Below 1 Ω
    H6-8 (E) - Body ground
    Always
    Below 1 Ω
    G59-11 (L2) - Body ground
    Always
    10 kΩ or higher
    G59-12 (UL2) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) (Click here)