SPIRAL CABLE > INSPECTION |
| 1. INSPECT SPIRAL CABLE WITH SENSOR SUB-ASSEMBLY |
Visually check for defects with the spiral cable with sensor sub-assembly removed from the vehicle.
The defects are as follows:
![]() |
Check the spiral cable with sensor sub-assembly.
| *a | Component without harness connected (Spiral Cable with Sensor Sub-assembly) |
Set the spiral cable with sensor sub-assembly to the center position .
Measure the resistance between each terminal of the spiral cable with sensor sub-assembly according to the table below.
| Tester Connection | Condition | Specified Condition |
| G5-1 (CCS) - z6-3 | Always | 3 Ω or less |
| G5-2 (ECC) - z6-4 | Always | 3 Ω or less |
| G5-3 (TX1) - z2-7 | Always | 3 Ω or less |
| G5-4 (EAU) - z2-8 | Always | 3 Ω or less |
| G5-5 (AU2) - z2-9 | Always | 3 Ω or less |
| G5-6 (AU1) - z2-10 | Always | 3 Ω or less |
| G5-8 (HO) - z2-1 | Always | 3 Ω or less |
| G5-9 (IG) - z2-2 | Always | 3 Ω or less |
| G5-10 (AC1) - z2-3 | Always | 3 Ω or less |
| G5-12 (IL+2) - z2-5 | Always | 3 Ω or less |
| G19-1 (D+) - z3-2 | Always | Below 1 Ω |
| G19-2 (D-) - z3-1 | Always | Below 1 Ω |
After setting the spiral cable with sensor sub-assembly to the center position, rotate the spiral cable with sensor sub-assembly 2.5 times clockwise, and measure the resistance as shown in the table below. Then rotate the spiral cable with sensor sub-assembly 5 times counterclockwise, and measure the resistance as shown in the table below.
| Tester Connection | Condition | Specified Condition |
| G5-1 (CCS) - z6-3 | Always | 3 Ω or less |
| G5-2 (ECC) - z6-4 | Always | 3 Ω or less |
| G5-3 (TX1) - z2-7 | Always | 3 Ω or less |
| G5-4 (EAU) - z2-8 | Always | 3 Ω or less |
| G5-5 (AU2) - z2-9 | Always | 3 Ω or less |
| G5-6 (AU1) - z2-10 | Always | 3 Ω or less |
| G5-8 (HO) - z2-1 | Always | 3 Ω or less |
| G5-9 (IG) - z2-2 | Always | 3 Ω or less |
| G5-10 (AC1) - z2-3 | Always | 3 Ω or less |
| G5-12 (IL+2) - z2-5 | Always | 3 Ω or less |
| G19-1 (D+) - z3-2 | Always | Below 1 Ω |
| G19-2 (D-) - z3-1 | Always | Below 1 Ω |
After setting the spiral cable with sensor sub-assembly to the center position, rotate the spiral cable with sensor sub-assembly 2.5 times clockwise. Then while rotating the spiral cable with sensor sub-assembly 5 times counterclockwise, measure the resistance as shown in the table below.
| Tester Connection | Condition | Specified Condition |
| G5-1 (CCS) - z6-3 | Always | 3 Ω or less |
| G5-2 (ECC) - z6-4 | Always | 3 Ω or less |
| G5-3 (TX1) - z2-7 | Always | 3 Ω or less |
| G5-4 (EAU) - z2-8 | Always | 3 Ω or less |
| G5-5 (AU2) - z2-9 | Always | 3 Ω or less |
| G5-6 (AU1) - z2-10 | Always | 3 Ω or less |
| G5-8 (HO) - z2-1 | Always | 3 Ω or less |
| G5-9 (IG) - z2-2 | Always | 3 Ω or less |
| G5-10 (AC1) - z2-3 | Always | 3 Ω or less |
| G5-12 (IL+2) - z2-5 | Always | 3 Ω or less |
| G19-1 (D+) - z3-2 | Always | Below 1 Ω |
| G19-2 (D-) - z3-1 | Always | Below 1 Ω |