INVERTER WITH CONVERTER > INSTALLATION |
| 1. INSTALL HIGH VOLTAGE FUSE |
![]() |
Remove the 2 bolts and inverter terminal cover.
| *1 | Interlock Connector |
![]() |
Remove the 7 bolts and inverter cover.
![]() |
Install the high voltage fuse with the 2 bolts.
| *a | Correct |
| *b | Incorrect |
![]() |
Temporarily install the inverter cover with the 7 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.
![]() |
Temporarily install the inverter terminal cover with the 2 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.
| *1 | Interlock Connector |
| 2. INSTALL INVERTER WITH CONVERTER ASSEMBLY |
![]() |
Temporarily install the inverter with converter assembly with the 3 bolts.
Tighten bolt (A).
Tighten the 2 bolts (B).
Disconnect the No. 2 engine room wire from the protector.
| 3. CONNECT NO. 1 INVERTER COOLING HOSE ASSEMBLY |
![]() |
Connect the No. 1 inverter cooling hose assembly to the inverter with converter assembly and lock the hose with the retainer.
| *1 | Retainer |
| 4. CONNECT NO. 2 INVERTER COOLING HOSE ASSEMBLY |
![]() |
Connect the No. 2 inverter cooling hose assembly to the inverter with converter assembly and lock the hose with the retainer.
| *1 | Retainer |
| 5. CONNECT FRAME WIRE |
Install the No. 2 engine room wire with the nut.
Install the No. 1 relay block cover with the 2 claws.
Connect the connector.
Install the relay block cover.
| 6. REMOVE INVERTER TERMINAL COVER |
![]() |
Remove the 2 bolts and inverter terminal cover.
| *1 | Interlock Connector |
| 7. REMOVE INVERTER COVER |
![]() |
Remove the 7 bolts and inverter cover.
| 8. CONNECT NO. 2 ENGINE WIRE |
![]() |
Temporarily install the No. 2 engine wire (high voltage cables of the air conditioning) with the 2 bolts (A) and 2 bolts (B) to the inverter with converter assembly.
Fully tighten the 2 bolts (A).
Fully tighten the 2 bolts (B).
Install the bracket with the bolt (C).
| 9. CONNECT MOTOR CABLE |
Connect the motor cable (MG2).
![]() |
Temporarily install the high voltage cable of the motor cable (MG2) with the 5 bolts to the inverter with converter assembly.
Fully tighten the 2 bolts (A).
Fully tighten the 3 bolts (B).
Connect the harness clamp.
Connect the motor cable (MG1).
![]() |
Temporarily install the high voltage cable of the motor cable (MG1) with the 5 bolts to the inverter with converter assembly.
Fully tighten the 2 bolts (A).
Fully tighten the 3 bolts (B).
| 10. CONNECT FRAME WIRE |
![]() |
Temporarily install the frame wire (high voltage cables of the hybrid battery) with the 4 bolts to the inverter with converter assembly.
| *1 | Interlock Connector |
| *2 | High voltage cables of hybrid battery |
| *a | Front view of frame wire connector |
Fully tighten the 2 bolts (A).
Fully tighten the 2 bolts (B).
Connect the harness clamp.
| 11. CHECK HIGH VOLTAGE CABLE CONNECTION |
![]() |
Check that each connector and terminal is firmly installed.
| 12. INSTALL INVERTER COVER |
![]() |
Temporarily install the inverter cover with the 7 bolts to the inverter with converter assembly.
Fully tighten the bolt (A).
Fully tighten the bolt (B).
Fully tighten the 5 bolts (C).
| 13. INSTALL INVERTER TERMINAL COVER |
![]() |
Temporarily install the inverter terminal cover with the 2 bolts to the inverter with converter assembly.
| *1 | Interlock Connector |
Fully tighten the bolt (A).
Fully tighten the bolt (B).
| 14. INSTALL ENGINE ROOM MAIN WIRE |
Connect the clamp.
Connect the engine room main wire with the 2 bolts.
Connect the hose clamp.
![]() |
Connect the engine wire to the engine room main wire.
![]() |
Connect the connector to the inverter with converter assembly and lock the connector with the lock lever.
| 15. INSTALL SERVICE PLUG GRIP |
| 16. ADD COOLANT (for Inverter) |
| DTC Code | Detection Item |
| P0A01-726 | Motor Electronics Coolant Temperature Sensor Circuit Range / Performance |
| P0A04-725 | Motor Electronics Coolant Temperature Sensor Circuit Intermittent |
| P0A08-264 | DC / DC Converter Status Circuit |
| P0A78-284 | Drive Motor "A" Inverter Performance |
| P0A78-286 | Drive Motor "A" Inverter Performance |
| P0A7A-322 | Generator Inverter Performance |
| P0A7A-324 | Generator Inverter Performance |
| P0A93-346 | Inverter Cooling System Performance |
| P0A94-553 | DC / DC Converter Performance |
| P0A94-557 | DC / DC Converter Performance |
| P0AEE-277 | Motor Inverter Temperature Sensor "A" Circuit Range / Performance |
| P0AF1-276 | Drive Motor Inverter Temperature Sensor "A" Circuit Intermittent / Erratic |
| P0BCD-315 | Generator Inverter Temperature Sensor Circuit Range / Performance |
| P0BD0-314 | Generator Inverter Temperature Sensor Circuit Intermittent / Erratic |
| P0C39-626 | DC / DC Converter Temperature Sensor "A" Range / Performance |
| P0C3C-625 | DC / DC Converter Temperature Sensor "A" Intermittent / Erratic |
| P0C3E-628 | DC / DC Converter Temperature Sensor "B" Range / Performance |
| P0C41-627 | DC / DC Converter Temperature Sensor "B" Intermittent / Erratic |
| P0C73-776 | Motor Electronics Coolant Pump "A" Control Performance |
![]() |
Slowly pour coolant into the reserve tank until it reaches the full line.
When using the intelligent tester:
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.
Keep the coolant at the full line in the reserve tank to compensate for the drop in coolant level when the air bleeds.
When not using the intelligent tester:
Turn the power switch on (READY). [*1]
Turn the power switch off and add coolant to the full line because the coolant level drops as the air bleeds. [*2]
Repeat steps [*1] and [*2] until air bleeding from the cooling system is completed.
After the air is completely bled from the cooling system, tighten the reserve tank cap.
![]() |
Add coolant to the full line of the reserve tank.
| 17. INSPECT FOR COOLANT LEAK (for Inverter) |
Remove the reserve tank cap.
![]() |
Install a radiator cap tester.
Pump the radiator cap tester to 122 kPa (1.2 kgf/ cm2, 18 psi), and then check that the pressure does not drop.
Reinstall the reserve tank cap.