Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › INVERTER WITH CONVERTER

INVERTER WITH CONVERTER > REMOVAL

for Preparation Click here



1. PRECAUTION
(Click here)


2. REMOVE SERVICE PLUG GRIP
(Click here)


3. DRAIN COOLANT (for Inverter)

NOTICE:
  1. Do not reuse the drained coolant because it may contain foreign matter.
  2. Collect the drained coolant and measure its volume to establish a benchmark. When adding coolant, make sure to add more coolant than the measured amount.

  1. Remove the reserve tank cap.

    CAUTION:
    To avoid the danger of being burned, do not remove the reserve tank cap while the coolant for the inverter is still hot.



    A266681
  1. Loosen the radiator drain cock plug and drain the coolant.

    CAUTION:
    Use caution when handling coolant immediately after driving or in summer because it may be hot.

  1. Tighten the radiator drain cock plug.



4. REMOVE INVERTER TERMINAL COVER


    A266706E01
  1. Remove the 2 bolts and inverter terminal cover.
    Text in Illustration 
    *1
    Interlock Connector

    CAUTION:
    An interlock connector is installed to the inverter terminal cover. Make sure to remove the inverter terminal cover before removing the inverter cover.

    NOTICE:
    Make sure to pull the inverter cover straight up, as a connector is connected to the bottom of the cover.



5. REMOVE INVERTER COVER

CAUTION:
Wear insulated gloves.



    A266688
  1. Remove the 7 bolts and inverter cover.

    CAUTION:
    An interlock connector is installed to the inverter terminal cover. Make sure to remove the inverter terminal cover before removing the inverter cover.



6. CHECK TERMINAL VOLTAGE

CAUTION:
Wear insulated gloves.

NOTICE:
Do not allow any foreign matter or water to enter the inverter with converter assembly.



    A267098
  1. Using a voltmeter, measure the voltage between the terminals of the 2 phase connectors.

    Standard voltage:
    0 V

    HINT:
    Use measuring range of DC 750 V or more on the voltmeter.



7. DISCONNECT ENGINE ROOM MAIN WIRE

CAUTION:
Wear insulated gloves.

NOTICE:
  1. Insulate the disconnected terminals with insulating tape.
  2. Cover the hole where the cable was connected with tape or equivalent (non-residue type) to prevent entry of foreign matter.
  3. To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.



    A266684
  1. Raise the lock lever and disconnect the inverter with converter connector.



    A214646
  1. Disconnect the engine wire from the engine room main wire.



    A266686
  1. Disconnect the hose clamp.

    NOTICE:
    Do not remove the hose clamp from the hose.

  1. Remove the 2 bolts.

  1. Disconnect the clamp and engine room main wire.



8. DISCONNECT FRAME WIRE

CAUTION:
Wear insulated gloves.

NOTICE:
  1. Insulate the disconnected terminals with insulating tape.
  2. Cover the hole where the cable was connected with tape or equivalent (non-residue type) to prevent entry of foreign matter.



    A266691
  1. Disconnect the harness clamp.



    A266689
  1. Remove the 4 bolts, and disconnect the frame wire (high voltage cables of the hybrid battery) from the inverter with converter assembly.



9. DISCONNECT MOTOR CABLE

CAUTION:
Wear insulated gloves.

NOTICE:
  1. Insulate the disconnected terminals with insulating tape.
  2. Cover the hole where the cable was connected with tape or equivalent (non-residue type) to prevent entry of foreign matter.



  1. Disconnect the motor cable (for MG 1)



      A266692
    1. Remove the 5 bolts, and disconnect the high voltage cables of the motor cable for (MG1) from the inverter with converter assembly.



  1. Disconnect the motor cable (for MG 2)



      A266693
    1. Remove the 5 bolts, and disconnect the high voltage cables of the motor cable (for MG2) from the inverter with converter assembly.



10. DISCONNECT NO. 2 ENGINE WIRE

CAUTION:
Wear insulated gloves.

NOTICE:
  1. Insulate the disconnected terminals with insulating tape.
  2. Cover the hole where the cable was connected with tape or equivalent (non-residue type) to prevent entry of foreign matter.



    A266694E03
  1. Remove the bolt (A).

  1. Remove the 4 bolts (B), and disconnect the No. 2 engine wire (high voltage cables for the air conditioning compressor) from the inverter with converter assembly.



11. INSTALL INVERTER COVER

CAUTION:
Wear insulated gloves.



    A266688
  1. Temporarily install the inverter cover with the 7 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.

    NOTICE:
    Visually confirm that the inverter cover waterproofing rubber is securely installed before installing the upper inverter cover.



12. INSTALL INVERTER TERMINAL COVER

CAUTION:
Wear insulated gloves.



    A266706E01
  1. Temporarily install the inverter terminal cover with the 2 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.
    Text in Illustration 
    *1
    Interlock Connector

    NOTICE:
    1. Visually confirm that the inverter cover waterproofing rubber is securely installed before installing the inverter terminal cover.
    2. Make sure that the interlock is fully engaged.



13. DISCONNECT FRAME WIRE


    A266697
  1. Remove the relay block cover.



    A266698
  1. Disconnect the connector.



    A266699
  1. Disengage the 2 claws and remove the No. 1 relay block cover.



    A267091
  1. Remove the nut and disconnect the No. 2 engine room wire.

  1. Release the 2 claws, and disconnect the No. 2 engine room wire.



14. DISCONNECT NO. 1 INVERTER COOLING HOSE ASSEMBLY


    A266702E01
  1. Release the retainer and disconnect the No. 1 inverter cooling hose assembly from the inverter with converter assembly.
    Text in Illustration 
    *1
    Retainer



    A266708
  1. Put pieces of cloth into the pipes and in the disconnected hose, or cover the pipes and hoses with plastic bags as shown in the illustration to prevent foreign matter from entering the cooling system and to prevent coolant from spilling near the inverter with converter assembly.



15. DISCONNECT NO. 2 INVERTER COOLING HOSE ASSEMBLY


    A266700E01
  1. Release the retainer and disconnect the No. 2 inverter cooling hose assembly from the inverter with converter assembly.
    Text in Illustration 
    *1
    Retainer



    A266708
  1. Put pieces of cloth into the pipes and in the disconnected hoses, or cover the pipes and hose with plastic bags as shown in the illustration to prevent foreign matter from entering the cooling system and to prevent coolant from spilling near the inverter with converter assembly.



16. REMOVE INVERTER WITH CONVERTER ASSEMBLY

CAUTION:
Wear insulated gloves.



    A266707E01
  1. Temporarily secure the No. 3 engine room wire with the inverter with converter assembly protector as shown in the illustration.
    Text in Illustration 
    *1
    Protector

    HINT:
    To prevent the No. 2 engine room wire from getting caught by other components, connect it to the protector before removing the inverter with converter assembly.



    A266704
  1. Remove the 3 bolts and inverter with converter assembly.

    NOTICE:
    1. Since the inverter with converter assembly is very heavy, 2 people are needed to remove the inverter with converter assembly. When removing the inverter with converter assembly, do not damage the parts around it.
    2. To prevent damage, do not hold the inverter with converter assembly by the connectors.
    3. To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.



    A148374
  1. Even after the coolant is drained, coolant remains in the inverter due to its internal structure. Therefore, seal or cover the pipes when removing the inverter so that coolant does not spill out.



17. REMOVE HIGH VOLTAGE FUSE

CAUTION:
Wear insulated gloves.

HINT:
Perform this procedure only when replacement of the high voltage fuse is necessary.



    A266706E01
  1. Remove the 2 bolts and inverter terminal cover.
    Text in Illustration 
    *1
    Interlock Connector

    NOTICE:
    Make sure to pull the inverter cover straight up, as a connector is connected to the bottom of the cover.



    A266688
  1. Remove the 7 bolts and inverter cover.



    A266696
  1. Remove the 2 bolts and high voltage fuse from the inverter with converter assembly.

    NOTICE:
    Do not allow any foreign matter or water to enter the inverter with converter assembly.



    A266688
  1. Temporarily install the inverter cover with the 7 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.

    NOTICE:
    Visually confirm that the inverter cover waterproofing rubber is securely installed before installing the inverter cover.



    A266706E01
  1. Temporarily install the inverter terminal cover with the 2 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.
    Text in Illustration 
    *1
    Interlock Connector

    NOTICE:
    1. Visually confirm that the inverter terminal cover waterproofing rubber is securely installed before installing the inverter terminal cover.
    2. Make sure that the interlock is fully engaged.