HV RELAY ASSEMBLY > INSPECTION |
| 1. INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY |
Inspect SMRB.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A-1 (+) - P5-1 (CBI) | Auxiliary battery voltage is not applied between terminals M40- 1 (SMRB) and M40-2 (GND) | 10 kΩ or higher |
| A-1 (+) - P5-1 (CBI) | Auxiliary battery voltage is applied between terminals M40- 1 (SMRB) and M40-2 (GND) | Below 1 Ω |
| *a | Component without harness connected (Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| M40-1 (SMRB) - M40-2 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω |
Inspect SMRG.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| c1-1 (-) - P4-1 (CEI) | Auxiliary battery voltage is not applied between terminals M40- 3 (SMRG) and M40-2 (GND) | 10 kΩ or higher |
| c1-1 (-) - P4-1 (CEI) | Auxiliary battery voltage is applied between terminals M40- 3 (SMRG) and M40-2 (GND) | Below 1 Ω |
| *a | Component without harness connected (Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| M40-3 (SMRG) - M40-2 (GND) | -40 to 80°C (-40 to 176°F) | 25.0 to 59.0 Ω |
Inspect SMRP.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| P4-1 (CEI) - c1-1 (-) | Auxiliary battery voltage is not applied between terminals M40-4 (SMRP) and M40-2 (GND) | 10 kΩ or higher |
| P4-1 (CEI) - c1-1 (-) | Auxiliary battery voltage is applied between terminals M40-4 (SMRP) and M40-2 (GND) | 28.5 to 31.5 Ω |
| *a | Component without harness connected (Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| M40-4 (SMRP) - M40-2 (GND) | -40 to 80°C (-40 to 176°F) | 112 to 274 Ω |