Home › Vehicle Interior › THEFT DETERRENT / KEYLESS ENTRY › ENGINE IMMOBILISER SYSTEM

ENGINE IMMOBILISER SYSTEM > Security Indicator Light Does not Blink

for Preparation Click here


DESCRIPTION

The certification ECU (smart key ECU assembly) blinks the security indicator light when the immobiliser is set (power switch off, or driver door is opened and closed with power switch on (IG)).

WIRING DIAGRAM


B271007E56


INSPECTION PROCEDURE

NOTICE:
  1. Before replacing the certification ECU (smart key ECU assembly), refer to Service Bulletin.
  2. When an engine immobiliser system DTC is output, first perform troubleshooting for the DTC.

1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (SECURITY INDICATOR LIGHT)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Turn the intelligent tester on.

  1. Enter the following menus: Body / Entry&Start / Active Test.

  1. Perform the Active Test according to the display on the intelligent tester.

    Entry&Start 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Immobiliser Indicator
    Security indicator light
    OFF/ON
    -

    OK:
    The security indicator light operates normally.



NG
Go to step 2
OK

REPLACE CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) 

2.CHECK HARNESS AND CONNECTOR (SECURITY INDICATOR LIGHT (COMBINATION METER ASSEMBLY) - CERTIFICATION ECU (SMART KEY ECU ASSEMBLY))
  1. Disconnect the G1 combination meter assembly connector.

  1. Disconnect the G79 certification ECU (smart key ECU assembly) connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    G79-18 (IND)- G1-13 (LP)
    Always
    Below 1 Ω
    G79-18 (IND) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.CHECK CERTIFICATION ECU (SMART KEY ECU ASSEMBLY)
  1. Reconnect the G79 certification ECU (smart key ECU assembly) connector.

  1. Measure the voltage and check the pulse according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    G1-13 (LP) - Body ground
    Power switch off → power switch on (IG)
    Pulse generation → Below 2 V



NG
REPLACE CERTIFICATION ECU (SMART KEY ECU ASSEMBLY)
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)