ELECTRONICALLY CONTROLLED BRAKE SYSTEM > INITIALIZATION |
| DESCRIPTION |
Perform initialization and calibration of the linear solenoid valve when the brake booster with master cylinder assembly, brake pedal stroke sensor assembly or brake pedal is replaced.
Follow the procedure to perform initialization.
| Part to be Replaced | Necessary Operation |
| Brake booster with master cylinder assembly | Initialization and calibration of the linear solenoid valve |
|
|
| PERFORM INITIALIZATION AND CALIBRATION OF LINEAR SOLENOID VALVE (When Using the Intelligent Tester) |
Clear the stored linear solenoid valve calibration data.
Turn the power switch off (lock).
Check that the steering wheel is centered.
Check that the shift lever is in P.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Select the skid control ECU to clear the linear solenoid valve calibration data using the intelligent tester. Enter the following menus: Chassis / ABS/VSC/TRC / Utility / Reset Memory.
Perform initialization and calibration of the linear solenoid valve.
Turn the power switch off (lock).
Check that the steering wheel is centered.
Check that the shift lever is in P.
Check that the parking brake is released.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG) with the brake pedal released.
Turn the intelligent tester on.
Switch the skid control ECU to Test Mode using the intelligent tester. Enter the following menus: Chassis / ABS/VSC/TRC / Utility / ECB* Utility / Linear Valve Offset.
*: Electronically Controlled Brake System
Leave the vehicle stationary without depressing the brake pedal for 1 or 2 minutes.
Check that the interval between blinks of the brake warning light / yellow (minor malfunction) changes from 1 second to 0.25 seconds.
Check that DTC C1345 (Linear Solenoid Valve Offset Learning Undone) which indicates trouble with stroke sensor zero point learning is not output when the brake warning light / yellow (minor malfunction) changes to the Test Mode blinking pattern upon completion of initialization and calibration of the linear solenoid valve.
Perform zero point calibration of the yaw rate and acceleration sensor (Click here).
Return to normal mode from Test Mode following the intelligent tester directions.
Turn the power switch off (lock) and disconnect the intelligent tester.
| PERFORM INITIALIZATION AND CALIBRATION OF LINEAR SOLENOID VALVE (When not Using the Intelligent Tester) |
Clear the stored linear solenoid valve calibration data.
Turn the power switch off (lock).
Check that the steering wheel is centered.
Check that the shift lever is in P.
Check that the parking brake is released.
Turn the power switch on (IG) with the brake pedal released.
![]() |
Using SST, connect and disconnect terminals TS and CG of the DLC3 4 times or more within 8 seconds.
| *a | Front view of DLC3 |
Check that no codes other than ABS code 42, VSC code 45 and electronically controlled brake system code 48, 66, or 95 are stored in the diagnostic system.
Perform initialization and calibration of the linear solenoid valve.
Turn the power switch off (lock).
Check that the steering wheel is centered.
Check that the shift lever is in P.
![]() |
Using SST, connect terminals TS and CG of the DLC3.
| *a | Front view of DLC3 |
Turn the power switch on (IG) with the brake pedal released.
Leave the vehicle stationary without depressing the brake pedal for 1 or 2 minutes.
Check that the interval between blinks of the brake warning light / yellow (minor malfunction) changes from 1 second to 0.25 seconds.
Check that DTC 66 (Linear Solenoid Valve Offset Learning Undone) which indicates trouble with stroke sensor zero point learning is not output when the brake warning light / yellow (minor malfunction) changes to the Test Mode blinking pattern upon completion of initialization and calibration of the linear solenoid valve completion.
Perform the zero point calibration of the yaw rate and acceleration sensor (Click here).
Turn the power switch off (lock) and disconnect SST from the DLC3.