DTC P0A1A-151 Generator Control Module |
DTC P0A1A-155 Generator Control Module |
DTC P0A1A-156 Generator Control Module |
DTC P0A1A-166 Generator Control Module |
DTC P0A1A-658 Generator Control Module |
DTC P0A1A-659 Generator Control Module |
DTC P0A1A-791 Generator Control Module |
DTC P0A1B-163 Drive Motor "A" Control Module |
DTC P0A1B-164 Drive Motor "A" Control Module |
DTC P0A1B-192 Drive Motor "A" Control Module |
DTC P0A1B-193 Drive Motor "A" Control Module |
DTC P0A1B-198 Drive Motor "A" Control Module |
DTC P0A1B-511 Drive Motor "A" Control Module |
DTC P0A1B-512 Drive Motor "A" Control Module |
DTC P0A1B-661 Drive Motor "A" Control Module |
DTC P0A1B-786 Drive Motor "A" Control Module |
DTC P0A1B-794 Drive Motor "A" Control Module |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A1A | 151 | Run pulse signal cycle deviation or stop | Inverter with converter assembly |
| 155 | A/D converter error | ||
| 156 | CPU ROM-RAM error | ||
| 166 | R/D converter NM stop error | ||
| 658 | ALU error | ||
| 659 | Communication error (from MG1 to MG2) | ||
| 791 | R/D converter communication error | ||
| P0A1B | 163 | IPM positive power source error | |
| 164 | IPM negative power source error | ||
| 192 | A/D converter error | ||
| 193 | CPU ROM-RAM error | ||
| 198 | R/D converter NM stop error | ||
| 511 | Standard voltage for analog signal offset | ||
| 512 | Standard voltage for analog signal error | ||
| 661 | Communication error (from MG2 to MG1) | ||
| 786 | ALU error | ||
| 794 | R/D converter communication error |
| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| None of the following DTCs are output. | A |
| Any of the following DTCs are output. | B |
| DTC No. | Relevant Diagnosis |
| P0A1A-155, 156, 166, 658, 791 | Generator Control Module |
| P0A1B-163, 164, 192, 193, 198, 511, 512, 661, 786, 794 | Drive Motor "A" Control Module |
Turn the power switch off.
|
| ||||
| A | |
| 2.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| Only DTC P0A1A-151, P0A1A-659 or P324E-788 is output. | A |
| Other than above. | B |
Turn the power switch off.
|
| ||||
| A | |
| 3.CLEAR DTC |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read and record the DTCs and freeze frame data.
Clear DTCs and freeze frame data.
Turn the power switch off.
| NEXT | |
| 4.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch off and wait for 30 seconds or more.
Turn the power switch on (IG) and wait for 5 seconds or more.
Turn the power switch on (READY).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| No DTCs are output (not including history DTCs). | A |
| Only DTC P0A1A-151, P0A1A-659 or P324E-788 is output. | B |
| Other than above. | C |
Turn the power switch off.
|
| ||||
|
| ||||
| A | ||
| ||