LIGHTING SYSTEM > ACC Signal Circuit |

| 1.CHECK DTC (SMART ENTRY AND START SYSTEM (for Start Function)) |
Check for DTCs (Click here).
| Result | Proceed to |
| DTC is not output | A |
| DTC is output | B |
|
| ||||
| A | |
| 2.READ VALUE USING INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Main Body / Data List.
Read the display on the intelligent tester.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| ACC SW | Power switch on (ACC) signal/ON or OFF | ON: Power switch on (ACC) OFF: Power switch off | - |
|
| ||||
| OK | ||
| ||
| 3.CHECK HARNESS AND CONNECTOR (DC/DC FUSE - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY) |
Disconnect the 3E*1 or 3F*2 instrument panel junction block assembly connectors.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 3E-1 - Body ground*1 | Power switch off | 11 to 14 V |
| 3F-1 - Body ground*2 | Power switch off | 11 to 14 V |
|
| ||||
| OK | |
| 4.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
Remove the instrument panel junction block assembly (Click here).
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
Measure the resistance according to the value(s) in the table below.

| *a | Component without harness connected (Instrument panel junction block assembly) | *b | for LHD |
| *c | for RHD | - | - |
| Tester Connection | Condition | Specified Condition |
| 3E-1 - MB-29 (ACC)*1 | Always | 10 kΩ or higher |
| 3E-1 - MB-29 (ACC)*1 | Auxiliary battery positive (+) → 3B-37 Auxiliary battery negative (-) → 3B-8 | Below 1 Ω |
| 3F-1 - MB-29 (ACC)*2 | Always | 10 kΩ or higher |
| 3F-1 - MB-29 (ACC)*2 | Auxiliary battery positive (+) → 3B-37 Auxiliary battery negative (-) → 3B-8 | Below 1 Ω |
|
| ||||
| OK | ||
| ||