OUTER MIRROR SWITCH > INSPECTION |
| 1. INSPECT OUTER MIRROR SWITCH ASSEMBLY (w/o Power Retractable Mirror) |
![]() |
Check the resistance.
| *1 | Left / Right Select Switch |
| *2 | Adjustment Switch |
| *a | Component without harness connected (Outer Mirror Switch Assembly) |
Select "L" on the left/right select switch.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition | |
| 4 (VL) - 8 (B) 6 (M+) - 7 (E) | UP | Pressed | Below 1 Ω |
| Not pressed | 10 kΩ or higher | ||
| 4 (VL) - 7 (E) 6 (M+) - 8 (B) | DOWN | Pressed | Below 1 Ω |
| Not pressed | 10 kΩ or higher | ||
| 5 (HL) - 8 (B) 6 (M+) - 7 (E) | LEFT | Pressed | Below 1 Ω |
| Not pressed | 10 kΩ or higher | ||
| 5 (HL) - 7 (E) 6 (M+) - 8 (B) | RIGHT | Pressed | Below 1 Ω |
| Not pressed | 10 kΩ or higher | ||
Select "R" on the left/right select switch.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition | |
| 3 (VR) - 8 (B) 6 (M+) - 7 (E) | UP | Pressed | Below 1 Ω |
| Not pressed | 10 kΩ or higher | ||
| 3 (VR) - 7 (E) 6 (M+) - 8 (B) | DOWN | Pressed | Below 1 Ω |
| Not pressed | 10 kΩ or higher | ||
| 2 (HR) - 8 (B) 6 (M+) - 7 (E) | LEFT | Pressed | Below 1 Ω |
| Not pressed | 10 kΩ or higher | ||
| 2 (HR) - 7 (E) 6 (M+) - 8 (B) | RIGHT | Pressed | Below 1 Ω |
| Not pressed | 10 kΩ or higher | ||
| 2. INSPECT OUTER MIRROR SWITCH ASSEMBLY (w/ Power Retractable Mirror) |
Check the mirror select switch and mirror surface adjust switch.
![]() |
Turn the mirror select switch to the L position.
Measure the resistance according to the value(s) in the table below.
| *1 | Mirror select switch |
| *2 | Mirror surface adjust switch |
| *a | Component without harness connected (Outer Mirror Switch Assembly) |
| Tester Connection | Switch Condition | Specified Condition |
| 4 (VL) - 8 (B) 6 (M+) - 7 (E) | UP | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 4 (VL) - 7 (E) 6 (M+) - 8 (B) | DOWN | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 5 (HL) - 8 (B) 6 (M+) - 7 (E) | LEFT | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 5 (HL) - 7 (E) 6 (M+) - 8 (B) | RIGHT | Below 1 Ω |
| OFF | 10 kΩ or higher |
Turn the mirror select switch to the R position.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 3 (VR) - 8 (B) 6 (M+) - 7 (E) | UP | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 3 (VR) - 7 (E) 6 (M+) - 8 (B) | DOWN | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 2 (HR) - 8 (B) 6 (M+) - 7 (E) | LEFT | Below 1 Ω |
| OFF | 10 kΩ or higher | |
| 2 (HR) - 7 (E) 6 (M+) - 8 (B) | RIGHT | Below 1 Ω |
| OFF | 10 kΩ or higher |
Check the mirror retract switch.
![]() |
Measure the resistance according to the value(s) in the table below.
| *1 | Mirror retract switch |
| *a | Component without harness connected (Outer Mirror Switch Assembly) |
| Tester Connection | Switch Condition | Specified Condition |
| 10 (MF) - 7 (E) | Mirror retract switch retract position | Below 1 Ω |
| 9 (MR) - 8 (B) | Below 1 Ω | |
| 10 (MF) - 8 (B) | Mirror retract switch return position | Below 1 Ω |
| 9 (MR) - 7 (E) | Below 1 Ω |