AIR CONDITIONING SYSTEM > CHECK MODE PROCEDURE |
| REFRIGERANT SHORTAGE CHECK IN NORMAL OPERATION (CHECK A/C SWITCH INDICATOR AND DTC) |
Turn the power switch to on (READY).
Check that the A/C switch indicator remains on when the following conditions are met.

| *A | for LHD | *B | for RHD |
| Item | Condition |
| A/C Switch | On |
| A/C operation time | 15 minutes or more |
| Ambient temperature* | 0 to 49°C (32 to 120°F) |
| Engine coolant temperature | 45°C (113°F) or more |
Connect the intelligent tester to the DLC3.
Check for DTC B14B8.
| Result | Amount of Refrigerant | Corrective Action |
| DTC B14B8 is output | Empty or nearly empty | Check for refrigerant leaks using a halogen leak detector, and repair if necessary (Click here). |
| DTC B14B8 is not output | Correct or insufficient | Perform a refrigerant shortage check using the intelligent tester. |
| REFRIGERANT SHORTAGE CHECK USING THE INTELLIGENT TESTER |
Connect the intelligent tester to the DLC3.
Turn the power switch to on (READY).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Utility / Refrigerant Shortage Check.
According to the display on the intelligent tester, perform the refrigerant shortage check when the following conditions are met.
| Item | Condition |
| A/C Switch | On |
| Ambient temperature* | 0 to 49°C (32 to 120°F) |
| R/F Switch | Fresh (Ambient temperature is 30°C (86°F) or more) |
| Recirculation (Ambient temperature is 31°C (87°F) or less) | |
| Blower Speed | HI |
| Temperature Setting | MAX HOT |
| Result | Amount of Refrigerant | Corrective Action |
| Refrigerant shortage | Insufficient or leakage |
|
| Refrigerant correct | Correct | - |