AIR CONDITIONING SYSTEM > DATA LIST / ACTIVE TEST |
| DATA LIST |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Room Temperature Sensor | Room temperature sensor (cooler thermistor) / Min.: -6.50°C (20.30°F) Max.: 57.25°C (135.05°F) | Actual cabin temperature displayed | - |
| Ambient Temp Sensor | Ambient temperature sensor (thermistor assembly) / Min.: -23.30°C (-9.94°F) Max.: 65.95°C (150.71°F) | Actual ambient temperature displayed | - |
| Adjusted Ambient Temp | Adjusted ambient temperature / Min.: -30.80°C (-23.44°F) Max.: 50.80°C (123.44°F) | - | - |
| Evaporator Fin Thermistor | Evaporator temperature sensor (No. 1 cooler thermistor) / Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) | Actual evaporator temperature displayed | - |
| Evaporator Target Temp | Evaporator target temperature / Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) | Evaporator target temperature displayed | - |
| Solar Sensor (D Side) | Solar sensor / Min.: 0 Max.: 255 | Solar sensor value increases as brightness increases | - |
| Engine Coolant Temp | Engine coolant temperature sensor / Min.: 1.30°C (34.34°F) Max.: 90.55°C (194.99°F) | Actual engine coolant temperature displayed | - |
| Set Temperature (D Side) | Set temperature / Min.: MAX COLD Max.: MAX HOT | Set temperature displayed | - |
| Blower Motor Speed Level | Blower motor speed level / Min.: 0 Max.: 31 | Displayed speed level increases in range between 0 and 31 as blower motor speed increases | - |
| Regulator Pressure Sensor | Air conditioning pressure sensor / Min.: -0.4566 MPaG Max.: 3.2943 MPaG | Actual pressure displayed | - |
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (air mix) target pulse / Min.: 128 Max.: 383 | MAX. COLD: 257 (pulse) MAX. HOT: 173 (pulse) | - |
| Air Mix Servo Actual Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (air mix) actual pulse / Min.: 128 Max.: 383 | MAX. COLD: 257 (pulse) MAX. HOT: 173 (pulse) | - |
| Air Outlet Servo Pulse (D) | No. 2 air conditioning radiator damper servo sub-assembly (air outlet) target pulse / Min.: 128 Max.: 383 | FACE: 267 (pulse) B/L: 250 (pulse) FOOT: 227 (pulse) FOOT/DEF: 220 (pulse) DEF: 206 (pulse) | - |
| Air Outlet Servo Actu Pulse(D) | No. 2 air conditioning radiator damper servo sub-assembly (air outlet) actual pulse / Min.: 128 Max.: 383 | FACE: 267 (pulse) B/L: 250 (pulse) FOOT: 227 (pulse) FOOT/DEF: 220 (pulse) DEF: 206 (pulse) | - |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly (air inlet) target pulse / Min.: 128 Max.: 383 | RECIRCULATION: 287 (pulse) FRESH: 254 (pulse) | - |
| Air Inlet Damper Actual Pulse | No. 1 blower damper servo sub-assembly (air inlet) actual pulse / Min.: 128 Max.: 383 | RECIRCULATION: 287 (pulse) FRESH: 254 (pulse) | - |
| Compressor Speed | Compressor speed / Min.: 0 rpm Max.: 65535 rpm | Actual compressor rotation speed displayed | - |
| Compressor Target Speed | Compressor target speed / Min.: 0 rpm Max.: 65535 rpm | Compressor target rotation speed displayed | - |
| Shift Set Temperature | Shift set temperature / 2C decr, 1C decr, Normal, 1C incr, 2C incr | Customized value displayed | - |
| Air Inlet Mode | Air inlet mode / Auto or Manual | Customized value displayed | - |
| Noise and Vibration Reduction | Noise and vibration reduction / OFF or ON | Customized value displayed | - |
| ECO MODE Cancel | ECO MODE Cancel / OFF or ON | Customized value displayed | - |
| ECO Switch | ECO mode switch (eco switch assembly) / OFF or ON | ECO mode switch (eco switch assembly) not operated: OFF (when switch is not pressed) | - |
| ECO mode switch (eco switch assembly) operated: ON (when switch is pressed) | - | ||
| Refrigerant Shortage Check | Refrigerant shortage check / ON or OFF | Customized value displayed | - |
| Fan speed increment control | Fan speed increment control / Slow, Normal, Fast | Customized value displayed | - |
| Foot/DEF Auto Mode | Foot/DEF Auto Mode / ON or OFF | Customized value displayed | - |
| Foot/DEF Auto Blow Up | Foot/DEF Auto blower speed increase / ON or OFF | Customized value displayed | - |
| Ambient Temperature Shift | Ambient temperature shift / 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr | Customized value displayed | - |
| Pls Servo Test Sts | Pulse servo motor test status/ Wait, Move, Comp, Error, Stop | Pulse servo motor test status | - |
| Compressor Drive Check | Compressor drive check / OK or NG | NG: Compressor does not drive OK: Compressor drives | - |
| Outside Air Mode Auto Switch Function | Outside air mode auto switch function / ON or OFF | Customized value displayed | - |
| Number of Trouble Codes | Number of trouble codes / Min.: 0 Max.: 255 | Number of DTCs displayed | - |
| ACTIVE TEST |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Blower Motor | Blower motor with fan sub-assembly | Min.: 0, Max.: 31 | - |
| Compressor Target Speed | Compressor with motor assembly | Min.: 0, Max.: 7500 | - |
| Defogger Relay (Rear) | Defogger relay | OFF, ON | - |
| Water Pump | Engine water pump assembly | OFF, ON | - |
| Electrical Fan | Electrical fan | OFF, ON | - |
| Air Mix Servo Targ Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly (air mix) pulse | Min.: 128, Max.: 383 | Operates between 173 and 257 pulses |
| Air Outlet Servo Pulse (D) | No. 2 air conditioning radiator damper servo sub-assembly (air outlet) pulse | Min.: 128, Max.: 383 | Operates between 206 and 267 pulses |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly (air inlet) target pulse | Min.: 128, Max.: 383 | Operates between 254 and 287 pulses |