Home › Vehicle Interior › LIGHTING (INT) › LIGHTING SYSTEM

LIGHTING SYSTEM > Interior Light Auto Cut Circuit

for Preparation Click here


DESCRIPTION

When battery saving control operates while the interior lights are on, the main body ECU (multiplex network body ECU) opens the DOME CUT relay to turn off the lights.

WIRING DIAGRAM


E245982E01


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Turn the intelligent tester on.

  1. Enter the following menus: Body / Main Body / Active Test.

  1. Check that the relay operates.

    Main Body 
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Relay for Interior Light Auto Cut Function
    DOME CUT Relay
    ON/OFF
    -

    OK:
    Dome cut relay operates.



NG
Go to step 2
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)  

2.INSPECT DOME CUT RELAY
  1. Remove the DOME CUT relay from the No. 2 engine room relay block and No. 2 junction block assembly.



    E222294E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Voltage is not applied between terminals 1 and 2
    10 kΩ or higher
    3 - 5
    Voltage is applied between terminals 1 and 2
    Below 1 Ω


    Result 
    Result
    Proceed to
    OK (LED Headlight Type or w/ Rear Fog Light)
    A
    OK (Halogen Headlight Type and w/o Rear Fog Light)
    B
    NG
    C
    Text in Illustration 
    *a
    Component without harness connected
    (DOME CUT Relay)



B
Go to step 4

C
REPLACE DOME CUT RELAY
A


3.CHECK HARNESS AND CONNECTOR (DOME CUT RELAY - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))
  1. Disconnect the G59 main body ECU (multiplex network body ECU) connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Relay terminal 1 - G59-15 (DOMR)
    Always
    Below 1 Ω
    Relay terminal 1 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) (Click here)  

4.CHECK HARNESS AND CONNECTOR (DOME CUT RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
  1. Disconnect the 3B instrument panel junction block assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Relay terminal 1 - 3B-34
    Always
    Below 1 Ω
    Relay terminal 1 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
  1. Remove the instrument panel junction block assembly (Click here).

  1. Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.



  1. Measure the resistance according to the value(s) in the table below.


    E173026E07


    Text in Illustration 
    *a
    Component without harness connected
    (Instrument Panel Junction Block Assembly)
    -
    -

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3B-34 - MB-26 (DOMR)
    Always
    Below 1 Ω



NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (Click here)
OK

REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) (Click here)