Home › Vehicle Interior › LIGHTING (INT) › LIGHTING SYSTEM

LIGHTING SYSTEM > Interior Light Power Source Circuit

for Preparation Click here


DESCRIPTION

The main body ECU (multiplex network body ECU) controls operation of the light cut relay in order to supply power to the interior lights.

WIRING DIAGRAM


E312608E01


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.

1.INSPECT DOME CUT RELAY
  1. Remove the DOME CUT relay from the No. 2 engine room relay block and No. 2 junction block assembly.



    E222294E03
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Voltage is not applied between terminals 1 and 2
    10 kΩ or higher
    3 - 5
    Voltage is applied between terminals 1 and 2
    Below 1 Ω

    Text in Illustration 
    *a
    Component without harness connected
    (DOME CUT Relay)



NG
REPLACE DOME CUT RELAY
OK


2.CHECK HARNESS AND CONNECTOR (AUXILIARY BATTERY - DOME CUT RELAY)
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    Relay Terminal 2 - Body ground
    Power switch off
    11 to 14 V
    Relay Terminal 5 - Body ground
    Power switch off
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.CHECK HARNESS AND CONNECTOR (DOME CUT RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
  1. Disconnect the 3C instrument panel junction block assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    Relay Terminal 3 - 3C-4
    Always
    Below 1 Ω
    Relay Terminal 3 - Body ground
    Always
    10 kΩ or higher


    Result 
    Result
    Proceed to
    OK (LED Headlight Type)
    A
    OK (Halogen Headlight Type)
    B
    NG
    C



B
Go to step 5

C
REPAIR OR REPLACE HARNESS OR CONNECTOR
A


4.CHECK HARNESS AND CONNECTOR (DOME CUT RELAY - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))
  1. Disconnect the G59 main body ECU (multiplex network body ECU) connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    Relay Terminal 1 - G59-15 (DOMR)
    Always
    Below 1 Ω
    Relay Terminal 1 - Body ground
    Always
    10 kΩ or higher


Result 
Result
Proceed to
NG
A
OK
B


B
Go to step 7
A

REPAIR OR REPLACE HARNESS OR CONNECTOR 

5.CHECK HARNESS AND CONNECTOR (DOME CUT RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
  1. Disconnect the 3B instrument panel junction block assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Relay terminal 1 - 3B-34
    Always
    Below 1 Ω
    Relay terminal 1 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
  1. Remove the instrument panel junction block assembly (Click here).

  1. Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.



  1. Measure the resistance according to the value(s) in the table below.


    E173026E07


    Text in Illustration 
    *a
    Component without harness connected
    (Instrument Panel Junction Block Assembly)
    -
    -

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3B-34 - MB-26 (DOMR)
    Always
    Below 1 Ω



NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (Click here)
OK


7.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
  1. Remove the instrument panel junction block assembly (Click here).

  1. Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.



  1. Measure the resistance according to the value(s) in the table below.


    E239259E01


    Text in Illustration 
    *a
    Component without harness connected
    (Instrument panel junction block assembly)
    -
    -

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    3C-4 - MB-3 (BCYL)
    Always
    Below 1 Ω
    3A-5 - MB-3 (BCYL)
    Always
    Below 1 Ω
    3D-6 - MB-4 (BCTL)
    Always
    Below 1 Ω



NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (Click here)
OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)