Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID BATTERY SYSTEM

DTC    P0A7F-123    Hybrid Battery Pack Deterioration

for Preparation Click here


DESCRIPTION


  1. The battery smart unit and the power management control ECU calculate the SOC (state of charge) of the HV battery through the accumulated amperage in the HV battery. The battery smart unit sends the condition of the HV battery to the power management control ECU. Then the power management control ECU calculates the SOC based on the information and controls HV battery charge and discharge according to the driving condition.


    A171602E02


    DTC No.
    INF Code
    DTC Detection Condition
    Trouble Area
    P0A7F
    123
    1. Internal resistance of the HV battery is higher than the standard (1 trip detection)
    2. Difference in the capacity between battery blocks is larger than the standard (2 trip detection)
    1. HV battery
    2. Battery smart unit

    HINT:
    1. P0A7F-123 will not be set unless the vehicle is driven for approximately 10 minutes after clearing the DTC. (As 2 trip detection logic is used, check for DTCs including pending DTCs.)
    2. In order to ensure HV battery performance, appropriate cooling performance must be maintained. Perform the following as necessary:
      1. Make sure the air intake port is not blocked.
      2. Clean the battery cooling blower filter.


INSPECTION PROCEDURE

CAUTION:
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

1.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Read output DTCs (Click here).

    Result:
    Result
    Proceed to
    P0AFC-123 is not output.
    A
    P0AFC-123 is also output.
    B

  1. Turn the power switch off.

  1. Disconnect the intelligent tester from the DLC3.



B
GO TO DTC CHART (P0AFC-123) (Click here)
A


2.READ VALUE USING INTELLIGENT TESTER (VB1 - VB10)
  1. Ensure the safety of the areas in front and at the back of the vehicle.

  1. Apply the parking brake and secure the wheels using chocks.

  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (READY).

  1. Fully warm up the engine and turn the air conditioning off.

  1. Enter the following menus: Powertrain / Hybrid Control / Data List / Battery block Vol -V01 to V10.

  1. Firmly depress the brake pedal with your left foot.

  1. Move the select lever to D.

  1. Record each battery block voltage from the data list "Battery block Vol -V01 to V10" while fully depressing the accelerator pedal.

  1. Compare the battery block voltages "Battery block Vol -V01 to V10" between the even and odd number groups in each combination shown in the table below.


Table 1 
Circuit A Battery Block
Circuit B Battery Block
Condition
Battery Block Vol -V01 (VB1)
Battery Block Vol -V02 (VB2)
"Battery Block Vol -V01" - "Battery Block Vol -V02" = 0.3 V or more
Battery Block Vol -V04 (VB4)
Battery Block Vol -V03 (VB3)
"Battery Block Vol -V04" - "Battery Block Vol -V03" = 0.3 V or more
Battery Block Vol -V05 (VB5)
Battery Block Vol -V06 (VB6)
"Battery Block Vol -V05" - "Battery Block Vol -V06" = 0.3 V or more
Battery Block Vol -V08 (VB8)
Battery Block Vol -V07 (VB7)
"Battery Block Vol -V08" - "Battery Block Vol -V07" = 0.3 V or more
Battery Block Vol -V09 (VB9)
Battery Block Vol -V10 (VB10)
"Battery Block Vol -V09" - "Battery Block Vol -V10" = 0.3 V or more

Table 2 
Circuit A Battery Block
Circuit B Battery Block
Condition
Battery Block Vol -V01 (VB1)
Battery Block Vol -V02 (VB2)
"Battery Block Vol -V02" - "Battery Block Vol -V01" = 0.3 V or more
Battery Block Vol -V04 (VB4)
Battery Block Vol -V03 (VB3)
"Battery Block Vol -V03" - "Battery Block Vol -V04" = 0.3 V or more
Battery Block Vol -V05 (VB5)
Battery Block Vol -V06 (VB6)
"Battery Block Vol -V06" - "Battery Block Vol -V05" = 0.3 V or more
Battery Block Vol -V08 (VB8)
Battery Block Vol -V07 (VB7)
"Battery Block Vol -V07" - "Battery Block Vol -V08" = 0.3 V or more
Battery Block Vol -V09 (VB9)
Battery Block Vol -V10 (VB10)
"Battery Block Vol -V10" - "Battery Block Vol -V09" = 0.3 V or more

A298791E01

HINT:
When an internal malfunction occurs in the battery smart unit, this symptom (difference in voltage of 0.3 V or more for all 5 pairs of blocks) will occur.

Result:
Result
Proceed to
All conditions in table 1 are met.
A
All conditions in table 2 are met.
Other than above.
B

  1. Turn the power switch off.



B
REPLACE HV BATTERY (Click here)
A

REPLACE BATTERY SMART UNIT (Click here)