DTC P0A95-123 High Voltage Fuse |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A95 | 123 | Voltage between VB8 and VB9 terminals is below the standard despite the interlock switch being engaged (1 trip detection) |
|

| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read output DTCs (Click here).
| Result | Proceed to |
| P0AFC-123 is not output. | A |
| P0AFC-123 is also output. | B |
Turn the power switch off.
Disconnect the intelligent tester from the DLC3.
|
| ||||
| A | |
| 2.CHECK SERVICE PLUG GRIP |
Turn the power switch off.
Check that the service plug grip is not installed.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Standard Resistance |
| Service plug grip | Below 1 Ω |
|
| ||||
| OK | ||
| ||
| 3.REPLACE SERVICE PLUG GRIP |
| NEXT | |
| 4.RECONFIRM DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read output DTCs (Click here).
| Result | Proceed to |
| DTCs are not output. | A |
| DTCs are also output. | B |
Disconnect the intelligent tester from the DLC3.
|
| ||||
| A | ||
| ||