DTC    P0A80-123    Replace Hybrid Battery Pack

for Preparation Click here


DESCRIPTION


  1. The HV battery uses nickel metal-hydride batteries and does not require external charging. The power management control ECU controls the SOC (state of charge) of the HV battery at a constant level during driving. The HV battery is composed of 20 modules, and each module consists of six 1.2 V cells in series. The battery smart unit monitors battery block voltage at 10 locations. Each battery block is composed of 2 modules in a set.


    A173707E15



    A298790E01


    DTC No.
    INF Code
    DTC Detection Condition
    Trouble Area
    P0A80
    123
    Difference in voltage between battery blocks is larger than the standard (2 trip detection)
    1. HV battery
    2. Battery smart unit

    HINT:
    1. P0A80-123 will not be set unless the vehicle is driven for approximately 10 minutes after clearing the DTC. (As 2 trip detection logic is used, check for DTCs including pending DTCs.)
    2. DTC P0A80-123 is stored when a malfunction is detected in the HV battery or battery smart unit. If the HV supply battery is malfunctioning, the malfunction may not be reproduced when the condition of the HV supply battery changes due to difference in driving load (amperage), battery SOC and battery temperature. Therefore, use the freeze frame data when performing a repair.
      1. When the HV battery is malfunctioning:
        1. - Voltage of 1 or a few battery blocks has dropped. (voltage difference from that of the next block is 1 V or more.)
        2. - Voltage of all battery blocks is output randomly with no certain pattern.
      1. When the battery smart unit is malfunctioning:
        1. - Differences in battery block voltages have a certain pattern.
    3. In order to ensure HV battery performance, appropriate cooling performance must be maintained. Perform the following as necessary:
      1. Make sure the air intake port is not blocked.
      2. Clean the battery cooling blower filter.


INSPECTION PROCEDURE

CAUTION:
When disposing of an HV battery, make sure to return it through an authorized collection agent who is capable of handling it safely. If the HV battery is returned via the manufacturer specified route, it will be returned properly and in a safe manner by an authorized collection agent.

1.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Read output DTCs (Click here).

    Result:
    Result
    Proceed to
    P0AFC-123 is not output.
    A
    P0AFC-123 is also output.
    B

  1. Turn the power switch off.

  1. Disconnect the intelligent tester from the DLC3.



B
GO TO DTC CHART (P0AFC-123) (Click here)
A


2.CHECK FREEZE FRAME DATA
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

  1. Read output DTCs.

  1. Using the intelligent tester, make a note of the freeze frame data item "Battery Block Vol -V01 to V10".



  1. Compare the freeze frame data item "Battery Block Vol -V01 to V10" values with those shown in the following combination tables.

    Table 1 
    Circuit A Battery Block
    Circuit B Battery Block
    Condition
    Battery Block Vol -V01 (VB1)
    Battery Block Vol -V02 (VB2)
    "Battery Block Vol -V01" - "Battery Block Vol -V02" = 0.3 V or more
    Battery Block Vol -V04 (VB4)
    Battery Block Vol -V03 (VB3)
    "Battery Block Vol -V04" - "Battery Block Vol -V03" = 0.3 V or more
    Battery Block Vol -V05 (VB5)
    Battery Block Vol -V06 (VB6)
    "Battery Block Vol -V05" - "Battery Block Vol -V06" = 0.3 V or more
    Battery Block Vol -V08 (VB8)
    Battery Block Vol -V07 (VB7)
    "Battery Block Vol -V08" - "Battery Block Vol -V07" = 0.3 V or more
    Battery Block Vol -V09 (VB9)
    Battery Block Vol -V10 (VB10)
    "Battery Block Vol -V09" - "Battery Block Vol -V10" = 0.3 V or more

    Table 2 
    Circuit A Battery Block
    Circuit B Battery Block
    Condition
    Battery Block Vol -V01 (VB1)
    Battery Block Vol -V02 (VB2)
    "Battery Block Vol -V02" - "Battery Block Vol -V01" = 0.3 V or more
    Battery Block Vol -V04 (VB4)
    Battery Block Vol -V03 (VB3)
    "Battery Block Vol -V03" - "Battery Block Vol -V04" = 0.3 V or more
    Battery Block Vol -V05 (VB5)
    Battery Block Vol -V06 (VB6)
    "Battery Block Vol -V06" - "Battery Block Vol -V05" = 0.3 V or more
    Battery Block Vol -V08 (VB8)
    Battery Block Vol -V07 (VB7)
    "Battery Block Vol -V07" - "Battery Block Vol -V08" = 0.3 V or more
    Battery Block Vol -V09 (VB9)
    Battery Block Vol -V10 (VB10)
    "Battery Block Vol -V10" - "Battery Block Vol -V09" = 0.3 V or more


    A298791E01

    HINT:
    When an internal malfunction occurs in the battery smart unit, this symptom (difference in voltage of 0.3 V or more for all 5 pairs of blocks) will occur.

    Result:
    Result
    Proceed to
    All conditions in table 1 are met.
    A
    All conditions in table 2 are met.
    Other than above
    B

  1. Turn the power switch off.



B
REPLACE HV BATTERY (Click here)
A

REPLACE BATTERY SMART UNIT (Click here)