Home › General › SPECIFICATIONS › 1NZ-FXE BATTERY / CHARGING

1NZ-FXE BATTERY / CHARGING > SERVICE DATA



Charging circuit without load
S34B20R
3 to 4 A
Positive (+) terminal - Negative (-) terminal
20°C (68°F), Power switch off
12.5 V or higher
Auxiliary battery is OK
11.0 to 12.5 V
Recharge auxiliary battery
Below 11.0 V
Replace auxiliary battery
Fuse
Standard resistance
Below 1 Ω
DC/ DC converter assembly
Current flowing from auxiliary battery Auxiliary battery positive cable
Power switch on (READY) (The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.)
0 A or less
(no current from auxiliary battery)
Auxiliary battery voltage Positive (+) terminal - Negative (-) terminal
13 to 15 V
Auxiliary battery thermometer sensor
Standard Resistance
1 - 2
3.00 to 3.73 kΩ at 10°C (50°F)
2.45 to 2.88 kΩ at 15°C (59°F)
1.95 to 2.30 kΩ at 20°C (68°F)
1.60 to 1.80 kΩ at 25°C (77°F)
1.28 to 1.47 kΩ at 30°C (86°F)
1.00 to 1.22 kΩ at 35°C (95°F)
0.80 to 1.00 kΩ at 40°C (104°F)
0.65 to 0.85 kΩ at 45°C (113°F)
0.50 to 0.70 kΩ at 50°C (122°F)
0.44 to 0.60 kΩ at 55°C (131°F)
0.36 to 0.50 kΩ at 60°C (140°F)