Home › Vehicle Exterior › LIGHTING (EXT) › AUTOMATIC HEADLIGHT BEAM LEVEL CONTROL SYSTEM

AUTOMATIC HEADLIGHT BEAM LEVEL CONTROL SYSTEM > PRECAUTION

for Preparation Click here



1.PRECAUTION FOR DISCONNECTING CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL

NOTICE:
When disconnecting the cable from the negative (-) auxiliary battery terminal, initialize the following system after the cable is reconnected:

System
See Procedure
Power Door Lock Control System
Click here


2.PRECAUTIONS WHEN USING INTELLIGENT TESTER
  1. When using the intelligent tester with the power switch off to troubleshoot: Connect the intelligent tester to the vehicle, and turn a courtesy light switch on and off at 1.5 second or less intervals until communication between the intelligent tester and vehicle begins.

  2. After all DTCs are cleared, check if the trouble occurs again 6 seconds after turning the power switch on (IG).