Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P0A4C-518    Generator Position Sensor Circuit Range / Performance

DTC    P0A4C-811    Generator Position Sensor Circuit Range / Performance

for Preparation Click here


DESCRIPTION

For a description of the inverter .
If the generator inverter overheats, has a circuit malfunction or has an internal short, the inverter transmits this information to the MG ECU via the generator inverter fail signal line.
If an abnormal amount of current flows through the generator inverter, the MG ECU detects it and sends a signal to inform the hybrid vehicle control ECU of the malfunction.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A4C
518
Generator inverter fail signal detection (overcurrent due to hybrid vehicle transaxle assembly malfunction)
  1. Inverter with converter assembly
  2. Hybrid vehicle transaxle assembly
  3. Wire harness or connector
811
Abnormal generator current value detection (hybrid vehicle transaxle assembly malfunction)

WIRING DIAGRAM

Refer to the wiring diagram for DTC P1CAC-200 .

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (Click here).

    HINT:
    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (Click here).

HINT:
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
  1. Turn the power switch on (READY) and wait for 5 seconds or more.
  2. Drive the vehicle for approximately 10 minutes mainly using the engine.

1.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    P0A7A-203 is not output.
    A
    P0A7A-203 is also output.
    B

    NOTICE:
    1. If P0A7A-203 is output, troubleshoot it first. After completing the troubleshooting for P0A7A-203, return to perform troubleshooting for this DTC.
    2. Parts repaired or replaced during troubleshooting for P0A7A-203 do not need to be re-inspected in this diagnosis procedure.

  1. Turn the power switch off.



B
GO TO DTC CHART (P0A7A-203) (Click here)
A


2.CHECK DTC OUTPUT (HYBRID CONTROL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Check if DTCs are output.

    HINT:
    1. If P0A7A-203 was not output in step 1 of this diagnosis procedure, check Table 1 below.
    2. If P0A7A-203 was output in step 1 of this diagnosis procedure, repair that DTC first, then check Table 2 below.

    Result:
    Result
    Proceed to
    Only P0A4C-518 or 811 is output, or DTCs other than the ones in the table below are also output.
    A
    Any of the DTCs are also output.
    B


    Table 1 
    DTC No.
    Relevant Diagnosis
    P06B0-163
    Sensor Power Supply "A" Circuit/Open
    P06D6-511
    Sensor Reference Voltage "F" Circuit/Open
    P06E6-164
    Sensor Power Supply "C" Circuit/Open
    P0A1A-151, 166, 658, 791
    Generator Control Module
    P0A1B-198, 786, 794
    Drive Motor "A" Control Module
    P0A1D (all INF codes)*1
    Hybrid Powertrain Control Module
    P0A3F-243
    Drive Motor "A" Position Sensor Circuit
    P0A40-500
    Drive Motor "A" Position Sensor Circuit Range/Performance
    P0A41-245
    Drive Motor "A" Position Sensor Circuit Low
    P0A4B-253
    Generator Position Sensor Circuit
    P0A4C-513
    Generator Position Sensor Circuit Range/Performance
    P0A4D-255
    Generator Position Sensor Circuit Low
    P0BEA-290
    Drive Motor "A" Phase V Current Sensor Circuit Range/Performance
    P0BEE-298
    Drive Motor "A" Phase W Current Sensor Circuit Range / Performance
    P0C76-523
    Hybrid Battery System Discharge Time Too Long
    P0D2E-586
    Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance
    P0D2F-266
    Drive Motor "A" Inverter Voltage Sensor Circuit Low
    P0D30-267
    Drive Motor "A" Inverter Performance
    P0E05-328
    Generator Phase V Current Sensor Circuit Range/Performance
    P0E09-336
    Generator Phase W Current Sensor Circuit Range/Performance
    P0E32-585
    DC/DC Converter Voltage Sensor "A" Range/Performance
    P0E33-589
    DC/DC Converter Voltage Sensor "A" Low
    P0E34-590
    DC/DC Converter Voltage Sensor "A" High
    P1C2A-155
    Generator A/D Converter Circuit
    P1C2B-192
    Drive Motor "A" A/D Converter Circuit
    P1C2D-587
    Hybrid Battery Voltage / DC/DC Converter Voltage Correlation
    P1C3C-294
    Drive Motor "A" Phase V Current Sensor Correlation
    P1C3D-302
    Drive Motor "A" Phase W Current Sensor Correlation
    P1C3E-333
    Generator Phase V Current Sensor Correlation
    P1C3F-341
    Generator Phase W Current Sensor Correlation
    P1C4A-288
    Drive Motor "A" Phase V Current Sensor Sub Circuit Range/Performance
    P1C4F-296
    Drive Motor "A" Phase W Current Sensor Sub Circuit Range/Performance
    P1C54-326
    Generator Phase V Current Sensor Sub Circuit Range/Performance
    P1C59-334
    Generator Phase W Current Sensor Sub Circuit Range/Performance
    P1C6D-501
    Drive Motor "A" Phase V Current Sensor Offset Range/Performance
    P1C6E-502
    Drive Motor "A" Phase W Current Sensor Offset Range/Performance
    P1C71-515
    Generator Phase V Current Sensor Offset Range/Performance
    P1C72-516
    Generator Phase W Current Sensor Offset Range/Performance
    P1C73-512
    Sensor Standard Voltage "F" Circuit/Open
    P1CA6-156
    Generator Control Module Malfunction
    P1CA7-193
    Drive Motor Control Module Malfunction
    P1CAC-200
    Generator Position Sensor Angle Malfunction
    P1CAD-168
    Drive Motor "A" Position Sensor Angle Malfunction
    P1CAF-792
    Generator Position Sensor REF Signal Cycle Malfunction
    P1CB0-795
    Drive Motor "A" Position Sensor REF Signal Cycle Malfunction
    P1CB2-793
    Generator Position Sensor REF Signal Stop Malfunction
    P1CB3-796
    Drive Motor "A" Position Sensor REF Signal Stop Malfunction
    P3133-659
    Communication Error from Generator to Drive Motor "A"
    P3134-661
    Communication Error from Drive Motor "A" to Generator

    Table 2 
    DTC No.
    Relevant Diagnosis
    P06B0-163
    Sensor Power Supply "A" Circuit/Open
    P06D6-511
    Sensor Reference Voltage "F" Circuit/Open
    P06E6-164
    Sensor Power Supply "C" Circuit/Open
    P0A1A-151, 166, 658, 791
    Generator Control Module
    P0A1B-198, 786, 794
    Drive Motor "A" Control Module
    P0A1D (all INF codes)*1
    Hybrid Powertrain Control Module
    P0A3F-243
    Drive Motor "A" Position Sensor Circuit
    P0A40-500
    Drive Motor "A" Position Sensor Circuit Range/Performance
    P0A41-245
    Drive Motor "A" Position Sensor Circuit Low
    P0A4B-253
    Generator Position Sensor Circuit
    P0A4C-513
    Generator Position Sensor Circuit Range/Performance
    P0A4D-255
    Generator Position Sensor Circuit Low
    P0BEA-290
    Drive Motor "A" Phase V Current Sensor Circuit Range/Performance
    P0BEE-298
    Drive Motor "A" Phase W Current Sensor Circuit Range / Performance
    P0C76-523
    Hybrid Battery System Discharge Time Too Long
    P0D2E-586
    Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance
    P0D2F-266
    Drive Motor "A" Inverter Voltage Sensor Circuit Low
    P0D30-267
    Drive Motor "A" Inverter Performance
    P0E32-585
    DC/DC Converter Voltage Sensor "A" Range/Performance
    P0E33-589
    DC/DC Converter Voltage Sensor "A" Low
    P0E34-590
    DC/DC Converter Voltage Sensor "A" High
    P1C2A-155
    Generator A/D Converter Circuit
    P1C2B-192
    Drive Motor "A" A/D Converter Circuit
    P1C2D-587
    Hybrid Battery Voltage / DC/DC Converter Voltage Correlation
    P1C3C-294
    Drive Motor "A" Phase V Current Sensor Correlation
    P1C3D-302
    Drive Motor "A" Phase W Current Sensor Correlation
    P1C3E-333
    Generator Phase V Current Sensor Correlation
    P1C3F-341
    Generator Phase W Current Sensor Correlation
    P1C4A-288
    Drive Motor "A" Phase V Current Sensor Sub Circuit Range/Performance
    P1C4F-296
    Drive Motor "A" Phase W Current Sensor Sub Circuit Range/Performance
    P1C6D-501
    Drive Motor "A" Phase V Current Sensor Offset Range/Performance
    P1C6E-502
    Drive Motor "A" Phase W Current Sensor Offset Range/Performance
    P1C73-512
    Sensor Standard Voltage "F" Circuit/Open
    P1CA6-156
    Generator Control Module Malfunction
    P1CA7-193
    Drive Motor Control Module Malfunction
    P1CAC-200
    Generator Position Sensor Angle Malfunction
    P1CAD-168
    Drive Motor "A" Position Sensor Angle Malfunction
    P1CAF-792
    Generator Position Sensor REF Signal Cycle Malfunction
    P1CB0-795
    Drive Motor "A" Position Sensor REF Signal Cycle Malfunction
    P1CB2-793
    Generator Position Sensor REF Signal Stop Malfunction
    P1CB3-796
    Drive Motor "A" Position Sensor REF Signal Stop Malfunction
    P3133-659
    Communication Error from Generator to Drive Motor "A"
    P3134-661
    Communication Error from Drive Motor "A" to Generator

    HINT:
    1. *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
    2. P0A4C-518 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.

  1. Turn the power switch off.



B
GO TO DTC CHART (HYBRID CONTROL SYSTEM) (Click here)
A


3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A267460
  1. Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).

    NOTICE:
    Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.

    OK:
    The connectors are connected securely and there are no contact pressure problems.

    HINT:
    When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.



NG
CONNECT SECURELY
OK


4.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector C28 from the inverter with converter assembly.

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the power switch on (IG).



    A217747E15
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    C28-11 (GRF) - Body ground
    Power switch on (IG)
    Below 1 V
    C28-12 (GRFG) - Body ground
    Power switch on (IG)
    Below 1 V
    C28-7 (GSN) - Body ground
    Power switch on (IG)
    Below 1 V
    C28-8 (GSNG) - Body ground
    Power switch on (IG)
    Below 1 V
    C28-10 (GCS) - Body ground
    Power switch on (IG)
    Below 1 V
    C28-9 (GCSG) - Body ground
    Power switch on (IG)
    Below 1 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    NOTICE:
    Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.CHECK GENERATOR RESOLVER

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector C28 from the inverter with converter assembly.



    A217747E15
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    C28-11 (GRF) - C28-12 (GRFG)
    Power switch off
    7.1 to 21.6 Ω
    C28-7 (GSN) - C28-8 (GSNG)
    Power switch off
    13.7 to 34.5 Ω
    C28-10 (GCS) - C28-9 (GCSG)
    Power switch off
    12.8 to 32.4 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    C28-11 (GRF) or C28-12 (GRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    C28-7 (GSN) or C28-8 (GSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    C28-10 (GCS) or C28-9 (GCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the inverter with converter assembly connector.



NG
Go to step 10
OK


6.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector C28 from the inverter with converter assembly.

  1. Connect the cable to the negative (-) auxiliary battery terminal.

  1. Turn the power switch on (IG).



    A217747E16
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    C28-1 (MRF) - Body ground
    Power switch on (IG)
    Below 1 V
    C28-2 (MRFG) - Body ground
    Power switch on (IG)
    Below 1 V
    C28-3 (MSN) - Body ground
    Power switch on (IG)
    Below 1 V
    C28-4 (MSNG) - Body ground
    Power switch on (IG)
    Below 1 V
    C28-6 (MCS) - Body ground
    Power switch on (IG)
    Below 1 V
    C28-5 (MCSG) - Body ground
    Power switch on (IG)
    Below 1 V

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

    NOTICE:
    Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

  1. Turn the power switch off.

  1. Disconnect the cable from the negative (-) auxiliary battery terminal.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


7.CHECK MOTOR RESOLVER

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector C28 from the inverter with converter assembly.



    A217747E16
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    C28-1 (MRF) - C28-2 (MRFG)
    Power switch off
    7.1 to 21.6 Ω
    C28-3 (MSN) - C28-4 (MSNG)
    Power switch off
    13.7 to 34.5 Ω
    C28-6 (MCS) - C28-5 (MCSG)
    Power switch off
    12.8 to 32.4 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    C28-1 (MRF) or C28-2 (MRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    C28-3 (MSN) or C28-4 (MSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    C28-6 (MCS) or C28-5 (MCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)

  1. Connect the inverter with converter assembly connector.



NG
Go to step 12
OK


8.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    A267571
  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


9.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    A267572
  1. Check the connection of the motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK

REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS (Click here)  

10.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    A267571
  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


11.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector C28 from the inverter with converter assembly.



    A268860E02
  1. Disconnect the generator resolver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    C28-11 (GRF) - C24-1 (GRF)
    Power switch off
    Below 1 Ω
    C28-12 (GRFG) - C24-5 (GRFG)
    Power switch off
    Below 1 Ω
    C28-7 (GSN) - C24-2 (GSN)
    Power switch off
    Below 1 Ω
    C28-8 (GSNG) - C24-6 (GSNG)
    Power switch off
    Below 1 Ω
    C28-10 (GCS) - C24-3 (GCS)
    Power switch off
    Below 1 Ω
    C28-9 (GCSG) - C24-7 (GCSG)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    C28-11 (GRF) or C24-1 (GRF) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    C28-12 (GRFG) or C24-5 (GRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    C28-7 (GSN) or C24-2 (GSN) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    C28-8 (GSNG) or C24-6 (GSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    C28-10 (GCS) or C24-3 (GCS) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    C28-9 (GCSG) or C24-7 (GCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)
    *b
    Front view of wire harness connector
    (to Generator Resolver)

    HINT:
    The generator resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.

  1. Connect the generator resolver connector.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)  

12.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    A267572
  1. Check the connection of the motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


13.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Disconnect connector C28 from the inverter with converter assembly.



    A268861E02
  1. Disconnect the motor resolver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Switch Condition
    Specified Condition
    C28-1 (MRF) - C26-3 (MRF)
    Power switch off
    Below 1 Ω
    C28-2 (MRFG) - C26-6 (MRFG)
    Power switch off
    Below 1 Ω
    C28-3 (MSN) - C26-1 (MSN)
    Power switch off
    Below 1 Ω
    C28-4 (MSNG) - C26-4 (MSNG)
    Power switch off
    Below 1 Ω
    C28-6 (MCS) - C26-2 (MCS)
    Power switch off
    Below 1 Ω
    C28-5 (MCSG) - C26-5 (MCSG)
    Power switch off
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Switch Condition
    Specified Condition
    C28-1 (MRF) or C26-3 (MRF) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    C28-2 (MRFG) or C26-6 (MRFG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    C28-3 (MSN) or C26-1 (MSN) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    C28-4 (MSNG) or C26-4 (MSNG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    C28-6 (MCS) or C26-2 (MCS) - Body ground and other terminals
    Power switch off
    1 MΩ or higher
    C28-5 (MCSG) or C26-5 (MCSG) - Body ground and other terminals
    Power switch off
    1 MΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter with Converter Assembly)
    *b
    Front view of wire harness connector
    (to Motor Resolver)

    HINT:
    The motor resolver is not available separately. If it requires replacement, replace the hybrid vehicle transaxle assembly.

  1. Connect the motor resolver connector.

  1. Connect the inverter with converter assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)