DTC P0A78-506 Drive Motor "A" Inverter Performance |
DTC P0A78-808 Drive Motor "A" Inverter Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A78 | 506 | Motor inverter fail signal detection (overcurrent due to hybrid vehicle transaxle assembly malfunction) |
|
| 808 | Abnormal MG2 current value detection (Hybrid vehicle transaxle assembly malfunction) |
| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| P0A78-202 is not output. | A |
| P0A78-202 is also output. | B |
Turn the power switch off.
|
| ||||
| A | |
| 2.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| Only P0A78-506 or 808 is output, or DTCs other than the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P0A1A (all INF codes)*1 | Generator Control Module |
| P0A1B (all INF codes)*1 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range / Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A60 (all INF codes)*1 | Drive Motor "A" Phase V Current |
| P0A63 (all INF codes)*1 | Drive Motor "A" Phase W Current |
| P0A72 (all INF codes)*1 | Generator Phase V Current |
| P0A75 (all INF codes)*1 | Generator Phase W Current |
| P0A78-266, 267, 586 | Drive Motor "A" Inverter Performance |
| P0A94-585, 587, 589, 590 | DC / DC Converter Performance |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| DTC No. | Relevant Diagnosis |
| P0A1A (all INF codes)*1 | Generator Control Module |
| P0A1B (all INF codes)*1 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range / Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A60-294 | Drive Motor "A" Phase V Current |
| P0A63-302 | Drive Motor "A" Phase W Current |
| P0A72 (all INF codes)*1 | Generator Phase V Current |
| P0A75 (all INF codes)*1 | Generator Phase W Current |
| P0A78-266, 267, 586 | Drive Motor "A" Inverter Performance |
| P0A94-585, 587, 589, 590 | DC / DC Converter Performance |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
Turn the power switch off.
|
| ||||
| A | |
| 3.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR) |
Check that the service plug grip is not installed.
![]() |
Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly (Click here).
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) - Body ground | Power switch on (IG) | Below 1 V |
| C28-12 (GRFG) - Body ground | Power switch on (IG) | Below 1 V |
| C28-7 (GSN) - Body ground | Power switch on (IG) | Below 1 V |
| C28-8 (GSNG) - Body ground | Power switch on (IG) | Below 1 V |
| C28-10 (GCS) - Body ground | Power switch on (IG) | Below 1 V |
| C28-9 (GCSG) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 5.CHECK GENERATOR RESOLVER |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) - C28-12 (GRFG) | Power switch off | 7.1 to 21.6 Ω |
| C28-7 (GSN) - C28-8 (GSNG) | Power switch off | 13.7 to 34.5 Ω |
| C28-10 (GCS) - C28-9 (GCSG) | Power switch off | 12.8 to 32.4 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) or C28-12 (GRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-7 (GSN) or C28-8 (GSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-10 (GCS) or C28-9 (GCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 6.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) - Body ground | Power switch on (IG) | Below 1 V |
| C28-2 (MRFG) - Body ground | Power switch on (IG) | Below 1 V |
| C28-3 (MSN) - Body ground | Power switch on (IG) | Below 1 V |
| C28-4 (MSNG) - Body ground | Power switch on (IG) | Below 1 V |
| C28-6 (MCS) - Body ground | Power switch on (IG) | Below 1 V |
| C28-5 (MCSG) - Body ground | Power switch on (IG) | Below 1 V |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 7.CHECK MOTOR RESOLVER |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) - C28-2 (MRFG) | Power switch off | 7.1 to 21.6 Ω |
| C28-3 (MSN) - C28-4 (MSNG) | Power switch off | 13.7 to 34.5 Ω |
| C28-6 (MCS) - C28-5 (MCSG) | Power switch off | 12.8 to 32.4 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) or C28-2 (MRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-3 (MSN) or C28-4 (MSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-6 (MCS) or C28-5 (MCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
|
| ||||
| OK | |
| 8.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 9.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | ||
| ||
| 10.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 11.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
![]() |
Disconnect the generator resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) - C24-1 (GRF) | Power switch off | Below 1 Ω |
| C28-12 (GRFG) - C24-5 (GRFG) | Power switch off | Below 1 Ω |
| C28-7 (GSN) - C24-2 (GSN) | Power switch off | Below 1 Ω |
| C28-8 (GSNG) - C24-6 (GSNG) | Power switch off | Below 1 Ω |
| C28-10 (GCS) - C24-3 (GCS) | Power switch off | Below 1 Ω |
| C28-9 (GCSG) - C24-7 (GCSG) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| C28-11 (GRF) or C24-1 (GRF) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-12 (GRFG) or C24-5 (GRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-7 (GSN) or C24-2 (GSN) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-8 (GSNG) or C24-6 (GSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-10 (GCS) or C24-3 (GCS) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-9 (GCSG) or C24-7 (GCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Generator Resolver) |
Connect the generator resolver connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||
| 12.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR) |
![]() |
Check the connection of the motor resolver connector.
|
| ||||
| OK | |
| 13.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER) |
Check that the service plug grip is not installed.
Disconnect connector C28 from the inverter with converter assembly.
![]() |
Disconnect the motor resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) - C26-3 (MRF) | Power switch off | Below 1 Ω |
| C28-2 (MRFG) - C26-6 (MRFG) | Power switch off | Below 1 Ω |
| C28-3 (MSN) - C26-1 (MSN) | Power switch off | Below 1 Ω |
| C28-4 (MSNG) - C26-4 (MSNG) | Power switch off | Below 1 Ω |
| C28-6 (MCS) - C26-2 (MCS) | Power switch off | Below 1 Ω |
| C28-5 (MCSG) - C26-5 (MCSG) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| C28-1 (MRF) or C26-3 (MRF) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-2 (MRFG) or C26-6 (MRFG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-3 (MSN) or C26-1 (MSN) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-4 (MSNG) or C26-4 (MSNG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-6 (MCS) or C26-2 (MCS) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| C28-5 (MCSG) or C26-5 (MCSG) - Body ground and other terminals | Power switch off | 1 MΩ or higher |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Front view of wire harness connector (to Motor Resolver) |
Connect the motor resolver connector.
Connect the inverter with converter assembly connector.
|
| ||||
| OK | ||
| ||