Home › Vehicle Interior › HEATING / AIR CONDITIONING › COMPRESSOR

COMPRESSOR > INSTALLATION

for Preparation Click here



1. INSPECT COMPRESSOR OIL


    E234976
  1. When replacing the compressor with motor assembly with a new one, gradually discharge the refrigerant gas from the service valve, and drain the following amount of oil from the new compressor with motor assembly before installation.

    Standard:
    (Oil capacity inside the new compressor with motor assembly: 115 to 130 cc (3.9 to 4.4 fl. oz.)) - (Remaining oil amount in the removed compressor with motor assembly) = (Oil amount to be removed from the new compressor)

    NOTICE:
    1. When checking the compressor oil level, observe the precautions on the cooler removal/installation.
    2. If a new compressor with motor assembly is installed without removing some oil, there will be too much oil in the system due to the oil remaining in the pipes of the vehicle. Excessive oil in the system prevents heat exchange in the refrigeration cycle and causes ineffective cooling.
    3. If the amount of oil remaining in the old compressor with motor assembly is too small, check the air conditioning system for oil leaks.
    4. Be sure to use ND-OIL 11 or equivalent compressor oil. If any compressor oil other than ND-OIL 11 is used, compressor with motor assembly insulation performance may decrease, resulting in a leak of electric power.



2. INSTALL COMPRESSOR WITH MOTOR ASSEMBLY


    E234975E01
  1. Install the compressor with motor assembly with the 3 bolts.

    HINT:
    Tighten the bolts in the order shown in the illustration.

    Torque:
    25 N*m{ 250 kgf*cm , 18 ft.*lbf }



    E234972E01
  1. Connect the connector <B>.
    Text in Illustration 
    *1
    Green-colored Lock

  1. Connect the connector <A> and slide the green-colored lock in the direction indicated by the arrow in the illustration to lock it securely.

    CAUTION:
    Make sure to wear insulating gloves.

    NOTICE:
    Make sure that the connector is connected securely.



3. CONNECT SUCTION HOSE SUB-ASSEMBLY
  1. Remove the vinyl tape from the hose.

  1. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the compressor with motor assembly.

    Compressor oil:
    ND-OIL 11 or equivalent

  1. Install the O-ring onto the suction hose sub-assembly.

  1. Install the suction hose sub-assembly to the compressor with motor assembly with the bolt.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }



4. CONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE
  1. Remove the vinyl tape from the hose.

  1. Sufficiently apply compressor oil to a new O-ring and the fitting surface of the compressor with motor assembly.

    Compressor oil:
    ND-OIL 11 or equivalent

  1. Install the O-ring onto the No. 1 cooler refrigerant discharge hose.

  1. Install the No. 1 cooler refrigerant discharge hose to the compressor with motor assembly with the bolt.

    Torque:
    9.8 N*m{ 100 kgf*cm , 87 in.*lbf }



5. INSTALL ENGINE UNDER COVER RH


6. INSTALL SERVICE PLUG GRIP
(Click here)


7. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT
  1. Perform vacuum purging using a vacuum pump or appropriate equipment.



  1. Charge the air conditioning system with refrigerant.

    Refrigerant type:
    HFC-134a (R134a)



    E247093E06


    Text in Illustration 
    *a
    Standard Charge Amount
    *b
    Mean Value in Proper Range
    *c
    Overcharged
    *d
    High Pressure
    *e
    Sub-cool System
    *f
    Refrigerant Amount
    *g
    +/-50 g (+/-1.76 oz)
    -
    -

    Standard charge amount:
    370 to 470 g (13.0 to 16.6 oz)

    SST
    09985-20010   (09985-02010, 09985-02050, 09985-02060, 09985-02070, 09985-02080, 09985-02090, 09985-02110, 09985-02130, 09985-02140, 09985-02150)

    NOTICE:
    1. Do not turn the A/C switch on before charging the air conditioning system with refrigerant. Doing so may cause the compressor to work without refrigerant, resulting in overheating of the compressor.
    2. The refrigerant amount should be checked by quantity (weight).
    3. The graph above is shown for reference only.

    HINT:
    Ensure that sufficient refrigerant is available to recharge the system when using a refrigerant recovery unit. Refrigerant recovery units are not always able to recover 100% of the refrigerant from an air conditioning system.



8. WARM UP COMPRESSOR
  1. Keep the A/C switch on for at least 2 minutes to warm up the compressor.

    NOTICE:
    To prevent damage to the compressor, be sure to warm up the compressor when turning the air conditioning on after removing and installing air conditioning system lines (including the compressor).



9. INSPECT FOR REFRIGERANT LEAK
  1. After recharging the air conditioning system with refrigerant, inspect for refrigerant leaks using a halogen leak detector.

  1. Carry out the test under the following conditions:

    1. Turn the power switch off.
    2. Ensure good ventilation (the halogen leak detector may react to volatile gases which are not refrigerant, such as gasoline vapor and exhaust gas).
    3. Repeat the inspection 2 or 3 times.
    4. Measure the pressure to make sure that there is some refrigerant remaining in the air conditioning system.
      Pressure when the compressor is off: approx. 392 to 588 kPa (3.9 to 5.9 kgf/cm2, 57 to 85 psi)



    I042222E40
  1. Using a halogen leak detector, inspect for refrigerant leaks from the air conditioning system.
    Text in Illustration 
    *1
    Halogen Leak Detector
    *a
    Inspect for Leak



    N014519E08
  1. Bring the halogen leak detector close to the drain hose with the detector power off, and then turn the detector on.
    Text in Illustration 
    *1
    Halogen Leak Detector
    *2
    Drain Hose

    HINT:
    1. After the blower motor has stopped, leave the cooling unit for more than 15 minutes.
    2. Bring the halogen leak detector sensor under the drain hose.
    3. When bringing the halogen leak detector close to the drain hose, make sure that the halogen leak detector does not react to volatile gases. If it is not possible to avoid interference from volatile gases, the vehicle should be lifted up to allow checking for leaks.

  1. If a refrigerant leak is not detected from the drain hose, remove the blower motor control from the cooling unit. Insert the halogen leak detector sensor into the unit and check for a leak.

  1. Disconnect the pressure sensor connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure sensor and check for a leak.

    HINT:
    When checking for leaks, the presence of oily dirt at a joint can indicate a leak.