COMPRESSOR > INSTALLATION |
| 1. INSPECT COMPRESSOR OIL |
![]() |
When replacing the compressor with motor assembly with a new one, gradually discharge the refrigerant gas from the service valve, and drain the following amount of oil from the new compressor with motor assembly before installation.
| 2. INSTALL COMPRESSOR WITH MOTOR ASSEMBLY |
![]() |
Install the compressor with motor assembly with the 3 bolts.
![]() |
Connect the connector <B>.
| *1 | Green-colored Lock |
Connect the connector <A> and slide the green-colored lock in the direction indicated by the arrow in the illustration to lock it securely.
| 3. CONNECT SUCTION HOSE SUB-ASSEMBLY |
Remove the vinyl tape from the hose.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the compressor with motor assembly.
Install the O-ring onto the suction hose sub-assembly.
Install the suction hose sub-assembly to the compressor with motor assembly with the bolt.
| 4. CONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE |
Remove the vinyl tape from the hose.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the compressor with motor assembly.
Install the O-ring onto the No. 1 cooler refrigerant discharge hose.
Install the No. 1 cooler refrigerant discharge hose to the compressor with motor assembly with the bolt.
| 5. INSTALL ENGINE UNDER COVER RH |
| 6. INSTALL SERVICE PLUG GRIP |
| 7. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT |
Perform vacuum purging using a vacuum pump or appropriate equipment.
Charge the air conditioning system with refrigerant.

| *a | Standard Charge Amount | *b | Mean Value in Proper Range |
| *c | Overcharged | *d | High Pressure |
| *e | Sub-cool System | *f | Refrigerant Amount |
| *g | +/-50 g (+/-1.76 oz) | - | - |
| 8. WARM UP COMPRESSOR |
Keep the A/C switch on for at least 2 minutes to warm up the compressor.
| 9. INSPECT FOR REFRIGERANT LEAK |
After recharging the air conditioning system with refrigerant, inspect for refrigerant leaks using a halogen leak detector.
Carry out the test under the following conditions:
![]() |
Using a halogen leak detector, inspect for refrigerant leaks from the air conditioning system.
| *1 | Halogen Leak Detector |
| *a | Inspect for Leak |
![]() |
Bring the halogen leak detector close to the drain hose with the detector power off, and then turn the detector on.
| *1 | Halogen Leak Detector |
| *2 | Drain Hose |
If a refrigerant leak is not detected from the drain hose, remove the blower motor control from the cooling unit. Insert the halogen leak detector sensor into the unit and check for a leak.
Disconnect the pressure sensor connector and leave it for approximately 20 minutes. Bring the halogen leak detector close to the pressure sensor and check for a leak.