COMPRESSOR > REMOVAL |
| 1. RECOVER REFRIGERANT FROM AIR CONDITIONING SYSTEM |
Start the hybrid system.
Operate the cooler compressor under the conditions show below:
| Item | Condition |
| Engine Speed | Idling |
| Operating Time | 3 minutes or more |
| A/C Switch Status | ON |
| Blower Switch Status | HI |
| Set Temperature | MAX COOL |
Stop the engine.
Recover the refrigerant from the A/C system using a refrigerant recovery unit.
| 2. REMOVE SERVICE PLUG GRIP |
| 3. CHECK TERMINAL VOLTAGE |
Remove the inverter terminal cover .
Remove the inverter cover .
Check the terminal voltage .
Install the inverter cover .
Install the inverter terminal cover .
| 4. REMOVE ENGINE UNDER COVER RH |
| 5. DISCONNECT NO. 1 COOLER REFRIGERANT DISCHARGE HOSE |
![]() |
Remove the bolt and disconnect the No. 1 cooler refrigerant discharge hose from the compressor with motor assembly.
Remove the O-ring from the No. 1 cooler refrigerant discharge hose.
| 6. DISCONNECT SUCTION HOSE SUB-ASSEMBLY |
![]() |
Remove the bolt and disconnect the suction hose sub-assembly from the compressor with motor assembly.
Remove the O-ring from the suction hose sub-assembly.
| 7. REMOVE COMPRESSOR WITH MOTOR ASSEMBLY |
![]() |
Using a screwdriver, slide the green-colored lock of the connector <A> in the direction indicated by the arrow in the illustration to release it and disconnect the connector.
| *1 | Green-colored Lock |
Disconnect the connector <B>.
![]() |
Remove the 3 bolts and the compressor with motor assembly.