Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P3110-223    HV Main Relay

for Preparation Click here


DESCRIPTION

The power management control ECU monitors the IGCT relay and detects the following malfunction.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P3110
223
There is a short to +B in the IGCT relay or the IGCT relay is stuck closed.
  1. Wire harness or connector
  2. IGCT relay
  3. Power management control ECU

WIRING DIAGRAM


A270250E01


INSPECTION PROCEDURE

HINT:
  1. When the circuit is shorted to +B, the auxiliary battery voltage will be applied to terminal +B1 or +B2 of the power management control ECU, even though the power switch is off.
  2. After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
    1. Turn the power switch on (IG) and wait for 15 seconds or more.
    2. Turn the power switch off and wait for 30 seconds or more.

1.INSPECT RELAY (IGCT)
  1. Remove the IGCT relay from the No. 2 engine room relay block and No. 2 junction block assembly.



    A253297E01
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 - 5
    Auxiliary battery voltage is not applied between terminals 1 and 2
    10 kΩ or higher

    Text in Illustration 
    *1
    IGCT Relay

  1. Install the IGCT relay.



NG
REPLACE RELAY (IGCT)
OK


2.CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - NO.2 ENGINE ROOM RELAY BLOCK AND NO. 2 JUNCTION BLOCK ASSEMBLY)
  1. Remove the IGCT relay from the No. 2 engine room relay block and No. 2 junction block assembly.

  1. Disconnect connector A38 and A39 from the power management control ECU.



  1. Measure the voltage according to the value(s) in the table below.


    A264141E01


    Text in Illustration 
    *1
    No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
    *2
    IGCT relay
    *a
    Rear view of wire harness connector
    (to Power Management Control ECU)
    -
    -

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A39-5 (+B1), A38-2 (+B2) or 5 (IGCT relay) - Body ground
    Power switch off
    Below 1 V

  1. Install the IGCT relay.

  1. Connect the power management control ECU connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE POWER MANAGEMENT CONTROL ECU (Click here)