Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

DTC    P314A-828    Inverter Coolant Pump Speed Signal

for Preparation Click here


DESCRIPTION

Refer to the description for DTC P0C73-776 .
The inverter water pump assembly sends the water pump speed (measured value) signal to the hybrid vehicle control ECU. If the inverter water pump speed (measured value) signal is not sent to the hybrid vehicle control ECU when the power switch is on (READY), this DTC is stored.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P314A
828
The water pump speed signal is not sent to the hybrid vehicle control ECU when the power switch is turned on (READY) or water pump revolution speed is extremely low or stop.*1
(1 trip detection logic)
  1. Wire harness or connector
  2. Hybrid vehicle control ECU
  3. Inverter water pump assembly
  4. IGCT NO. 3 fuse
  1. *1: Malfunction (open, short to +B or short to ground) in the speed signal line from the inverter water pump assembly or inverter water pump assembly power source circuit malfunction is suspected.
  2. A malfunction (open, short to +B or short to ground) in the speed signal line from the inverter water pump assembly to the hybrid vehicle control computer is detected.
  3. A malfunction in the inverter water pump assembly power source circuit is detected.
  4. A malfunction in the +B line or speed signal line to the inverter water pump assembly is detected.
  5. A malfunction in the inverter water pump assembly power source circuit or hybrid vehicle control computer power source circuit is detected.

Related Data List 
DTC No.
Data List
P314A-828
  1. Inverter W/P Revolution*2
  2. W/P Run Control Duty*2
  3. Ready Signal
  1. *2: This Data List item is related to the inverter water pump assembly.

Related Active Test 
DTC No.
Active Test
P314A-828
Activate the Water Pump*3
  1. *3: This is an Active Test of the inverter water pump assembly.

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0C73-776 .

INSPECTION PROCEDURE

HINT:
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
  1. Turn the power switch on (READY) and wait for 2 minutes or more.

1.CLEAR DTC
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Read and record the DTCs and freeze frame data.

  1. Clear DTCs and freeze frame data.

  1. Turn the power switch off.


NEXT


2.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (ACTIVATE THE WATER PUMP)

NOTICE:
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.

HINT:
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.

  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.

  1. Perform the Activate the Water Pump Active Test.

  1. Touch the inverter water pump assembly and check that it is operating (vibrating).

    OK:
    The inverter water pump is operating (vibrating).

  1. Turn the power switch off.



NG
Go to step 9
OK


3.CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)


    A279820E01
  1. Check the connector connections and contact pressure of the relevant terminals for the hybrid vehicle control ECU connectors (Click here).
    Text in Illustration 
    *A
    for LHD
    *B
    for RHD

    OK:
    The connectors are connected securely and there are no contact pressure problems.



NG
CONNECT SECURELY
OK


4.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WATER PUMP ASSEMBLY CONNECTOR)


    A267464
  1. Check the connector connections and contact pressure of the relevant terminals for the inverter water pump assembly connector (Click here).

    OK:
    The connectors are connected securely and there are no contact pressure problems.



NG
CONNECT SECURELY
OK


5.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - INVERTER WATER PUMP ASSEMBLY)
  1. Disconnect connector A71 from the hybrid vehicle control ECU.

  1. Disconnect connector A53 from the inverter water pump assembly.



  1. Measure the resistance according to the value(s) in the table below.


    A265405E27


    Text in Illustration 
    *a
    Rear view of wire harness connector
    (to Hybrid Vehicle Control ECU)
    *b
    Front view of wire harness connector
    (to Inverter Water Pump Assembly)

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A71-14 (NIWP) - A53-2 (NWP)
    Power switch off
    Below 1 Ω
    A71-14 (NIWP) or A53-2 (NWP) -Body ground and other terminals
    Power switch off
    10 kΩ or higher

  1. Connect the hybrid vehicle control ECU connector.

  1. Connect the inverter water pump assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.CHECK HYBRID VEHICLE CONTROL ECU
  1. Disconnect connector A53 from the inverter water pump assembly.

  1. Turn the power switch on (IG).



    A249750E45
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A71-14 (NIWP) - G80-6 (E1)
    Power switch on (IG)
    11 to 14 V

    Text in Illustration 
    *a
    Component with harness connected
    (Hybrid Vehicle Control ECU)

  1. Turn the power switch off.

  1. Connect the inverter water pump assembly connector.



NG
REPLACE HYBRID VEHICLE CONTROL ECU (Click here)
OK


7.CLEAR DTC
  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / DTC.

  1. Read and record the DTCs and freeze frame data.

  1. Clear DTCs and freeze frame data.

  1. Turn the power switch off.


NEXT


8.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (ACTIVATE THE WATER PUMP)

NOTICE:
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.

HINT:
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.

  1. Connect the intelligent tester to the DLC3.

  1. Turn the power switch on (IG).

  1. Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.

  1. Perform the "Activate the Water Pump" Active Test.



    A281217E13
  1. Connect an oscilloscope between the hybrid vehicle control ECU terminals specified in the table below, and measure the waveform.
    Item
    Content
    Terminal
    A71-14 (NIWP) - G80-6 (E1)
    Equipment Setting
    5 V/DIV., 100 ms./DIV.
    Condition
    Powern switch ON (IG), during Active Test

    OK:
    The duration of wavelength A is 300 msec or less.

    Text in Illustration 
    *a
    Component with harness connected
    (Hybrid Vehicle Control ECU)

  1. Turn the power switch off.



NG
REPLACE INVERTER WATER PUMP ASSEMBLY (Click here)
OK

REPLACE HYBRID VEHICLE CONTROL ECU (Click here)  

9.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WATER PUMP ASSEMBLY CONNECTOR)


    A267464
  1. Check the connector connections and contact pressure of the relevant terminals for the inverter water pump assembly connector (Click here).

    OK:
    The connectors are connected securely and there are no contact pressure problems.



NG
Go to step 12
OK


10.CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY - IGCT RELAY)
  1. Remove the IGCT relay from the No. 2 engine room relay block and No. 2 junction block assembly.

  1. Disconnect connector A53 from the inverter water pump assembly.



  1. Measure the resistance according to the value(s) in the table below.


    A298744E01


    Text in Illustration 
    *1
    No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
    *2
    IGCT Relay
    *a
    Front view of wire harness connector
    (to Inverter Water Pump Assembly)
    -
    -

    Standard Resistance:

    Tester Connection
    Switch Condition
    Specified Condition
    A53-4 (+BWP) - 5 (IGCT relay)
    Power switch off
    Below 1 Ω

    HINT:
    1. Connectors
      Slightly shake the connector vertically and horizontally.
    2. Wire Harness
      Slightly shake the wire harness vertically and horizontally.
      The connector joint and fulcrum of the vibration are the major areas that should be checked thoroughly.
    3. No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
      Apply slight vibration with a finger to the No. 2 engine room relay block and No. 2 junction block assembly and check whether a malfunction occurs.

    4. A288054E02
      IGCT NO. 3 Fuse
      Apply slight vibration with a finger to the IGCT NO. 3 fuse and check whether a malfunction occurs.
      Text in Illustration 
      *a
      Example
      *b
      Shake Slightly
      *c
      Vibrate Slightly

    NOTICE:
    Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.

  1. Install the IGCT relay.

  1. Connect the inverter water pump assembly connector.



NG
Go to step 13
OK


11.CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY - BODY GROUND)
  1. Disconnect connector A53 from the inverter water pump assembly.



    A288050E06
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A53-1 (GND) - Body ground
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter Water Pump Assembly)

  1. Connect the inverter water pump assembly connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE INVERTER WATER PUMP ASSEMBLY (Click here)  

12.CHECK FUSE (IGCT NO. 3)


    A263625E01
  1. Remove the IGCT NO. 3 fuse from the No. 2 engine room relay block and No. 2 junction block assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    IGCT NO. 3 fuse
    Always
    Below 1Ω

    Text in Illustration 
    *1
    No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
    *2
    IGCT NO. 3 Fuse

  1. Install the IGCT NO. 3 fuse.



NG
Go to step 23
OK

CONNECT SECURELY (INVERTER WATER PUMP ASSEMBLY CONNECTOR) 

13.CHECK INSTALLATION CONDITION (IGCT NO. 3 FUSE)
  1. Check the terminals of the IGCT NO. 3 fuse holder.

    OK:
    The terminals of the IGCT NO. 3 fuse holder are not bent, loose or corroded.



NG
Go to step 16
OK


14.CHECK HARNESS AND CONNECTOR (INVERTER WATER PUMP ASSEMBLY CIRCUIT)
  1. Remove the IGCT NO. 3 fuse from the No. 2 engine room relay block and No. 2 junction block assembly.

  1. Remove the IGCT relay from the No. 2 engine room relay block and No. 2 junction block assembly.

  1. Disconnect connector A53 from the inverter water pump assembly.



  1. Measure the resistance according to the value(s) in the table below.


    A298745E01


    Text in Illustration 
    *1
    No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
    *2
    IGCT NO. 3 Fuse
    *3
    IGCT Relay
    -
    -
    *a
    Front view of wire harness connector
    (to Inverter Water Pump Assembly)
    -
    -

    Standard Resistance:

    Tester Connection
    Switch Condition
    Specified Condition
    A53-4 (+BWP) - 2 (IGCT NO. 3 fuse)
    Power switch off
    Below 1 Ω
    1 (IGCT NO. 3 fuse) - 5 (IGCT relay)
    Power switch off
    Below 1 Ω
    A53-4 (+BWP) or 2 (IGCT NO. 3 fuse) - Body ground and other terminals
    Powern switch off
    10 kΩ or higher
    1 (IGCT NO. 3 fuse) or 5 (IGCT relay) - Body ground and other terminals
    Power switch off
    10 kΩ or higher

    NOTICE:
    Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.

  1. Install the IGCT NO. 3 fuse.

  1. Install the IGCT relay.

  1. Connect the inverter water pump assembly connector.



NG
Go to step 18
OK


15.CHECK FUSE (IGCT NO. 3)


    A263625E01
  1. Remove the IGCT NO. 3 fuse from the No. 2 engine room relay block and No. 2 junction block assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    IGCT NO. 3 fuse
    Always
    Below 1Ω

    Text in Illustration 
    *1
    No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
    *2
    IGCT NO. 3 Fuse

  1. Install the IGCT NO. 3 fuse.



NG
Go to step 19
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR 

16.CHECK FUSE HOLDER TERMINAL (IGCT NO. 3 FUSE)
  1. Check the terminals of the IGCT NO. 3 fuse holder.

    OK:
    The terminals of the IGCT NO. 3 fuse holder are not bent, loose or corroded.



NG
Go to step 22
OK


17.CHECK FUSE (IGCT NO. 3)


    A263625E01
  1. Remove the IGCT NO. 3 fuse from the No. 2 engine room relay block and No. 2 junction block assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    IGCT NO. 3 fuse
    Always
    Below 1Ω

    Text in Illustration 
    *1
    No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
    *2
    IGCT NO. 3 Fuse

  1. Install the IGCT NO. 3 fuse.



NG
REPLACE FUSE (IGCT NO. 3)
OK

CONNECT SECURELY (IGCT NO. 3 FUSE) 

18.CHECK FUSE (IGCT NO. 3)


    A263625E01
  1. Remove the IGCT NO. 3 fuse from the No. 2 engine room relay block and No. 2 junction block assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    IGCT NO. 3 fuse
    Always
    Below 1Ω

    Text in Illustration 
    *1
    No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
    *2
    IGCT NO. 3 Fuse

  1. Install the IGCT NO. 3 fuse.



NG
Go to step 24
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR 

19.CHECK HARNESS AND CONNECTOR ((INVERTER WATER PUMP ASSEMBLY - BODY GROUND)
  1. Disconnect connector A53 from the inverter water pump assembly.



    A288050E06
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A53-1 (GND) - Body ground
    Power switch off
    10 kΩ or higher

    Text in Illustration 
    *a
    Front view of wire harness connector
    (to Inverter Water Pump Assembly)

  1. Connect the inverter water pump assembly connector.



NG
Go to step 24
OK


20.CHECK FUSE HOLDER TERMINAL (IGCT NO. 3 FUSE)
  1. Check the terminals of the IGCT NO. 3 fuse holder.

    OK:
    The terminals of the IGCT NO. 3 fuse holder are not bent, loose or corroded.



NG
Go to step 25
OK


21.REPLACE INVERTER WATER PUMP ASSEMBLY
(Click here)

NEXT

REPLACE FUSE (IGCT NO. 3) 

22.CHECK FUSE (IGCT NO. 3)


    A263625E01
  1. Remove the IGCT NO. 3 fuse from the No. 2 engine room relay block and No. 2 junction block assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    IGCT NO. 3 fuse
    Always
    Below 1Ω

    Text in Illustration 
    *1
    No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
    *2
    IGCT NO. 3 Fuse

  1. Install the IGCT NO. 3 fuse.



NG
Go to step 25
OK


23.CONNECT SECURELY
  1. Connect the inverter water pump assembly connector securely.


NEXT

REPLACE FUSE (IGCT NO. 3) 

24.REPAIR OR REPLACE HARNESS OR CONNECTOR

NEXT

REPLACE FUSE (IGCT NO. 3) 

25.REPAIR OR REPLACE HARNESS OR CONNECTOR (IGCT NO. 3 FUSE HOLDER TERMINAL)

NEXT

REPLACE FUSE (IGCT NO. 3)