Home › Vehicle Interior › METER / GAUGE / DISPLAY › METER / GAUGE SYSTEM

DTC    B1507    Open in Turn Signal Circuit

DTC    B1508    Short in Turn Signal / Hazard Flasher Circuit

for Preparation Click here


DESCRIPTION

These DTCs are stored when the combination meter assembly detects an open in a turn signal light circuit, a short in a turn signal light circuit, or a short in the hazard warning light circuit.

DTC No.
DTC Detection Condition
Trouble Area
B1507
When IG voltage is 9.5 V or more and the following condition is detected:
  1. Open in turn signal light circuit
  1. Harness or connector
  2. Bulb
  3. Instrument panel junction block assembly
  4. Combination meter assembly
B1508
When IG voltage is 9.5 V or more and the following condition is detected:
  1. Short in turn signal light circuit or hazard warning light circuit
  1. Harness or connector
  2. Bulb
  3. Instrument panel junction block assembly
  4. Combination meter assembly

WIRING DIAGRAM


for Halogen Headlight

E230178E14


for LED Headlight

E230178E13


INSPECTION PROCEDURE

NOTICE:
Inspect the bulbs for this system before performing the following inspection procedure.

1.INSPECT LIGHTS
  1. Inspect the illumination of each turn signal light.

Result:
Result
Proceed to
Turn signal lights for one side do not illuminate.
A
Front turn signal light does not illuminate.
B
Rear turn signal light does not illuminate.
C
Side turn signal light does not illuminate.
D



B
Go to step 3

C
Go to step 4

D
Go to step 5
A


2.CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
  1. Disconnect the G3 combination meter assembly connector.

  1. Disconnect the 3B instrument panel junction block assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    for LH 
    Tester Connection
    Condition
    Specified Condition
    G3-13 (LL) - 3B-24
    Always
    Below 1 Ω
    for RH 
    Tester Connection
    Condition
    Specified Condition
    G3-7 (LR) - 3B-25
    Always
    Below 1 Ω


    Standard Resistance (Check for Short):
    for LH 
    Tester Connection
    Condition
    Specified Condition
    G3-13 (LL) - Body ground
    Always
    10 kΩ or higher
    for RH 
    Tester Connection
    Condition
    Specified Condition
    G3-7 (LR) - Body ground
    Always
    10 kΩ or higher

Result:
Result
Proceed to
NG
A
OK
B



B
Go to step 6
A

REPAIR OR REPLACE HARNESS OR CONNECTOR 

3.CHECK HARNESS AND CONNECTOR (HEADLIGHT ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
  1. for Halogen Headlight

    1. Disconnect the A7*1 or A8*2 front turn signal light connector.

      1. *1: for RH
      2. *2: for LH

    2. Disconnect the 3C instrument panel junction block assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open):
      for LH 
      Tester Connection
      Condition
      Specified Condition
      A8-1 (B) - 3C-28
      Always
      Below 1 Ω
      A8-2 (E) - Body ground
      Always
      Below 1 Ω
      for RH 
      Tester Connection
      Condition
      Specified Condition
      A7-1 (B) - 3C-38
      Always
      Below 1 Ω
      A7-2 (E) - Body ground
      Always
      Below 1 Ω


      Standard Resistance (Check for Short):
      for LH 
      Tester Connection
      Condition
      Specified Condition
      A8-1 (B) - Body ground
      Always
      10 kΩ or higher
      for RH 
      Tester Connection
      Condition
      Specified Condition
      A7-1 (B) - Body ground
      Always
      10 kΩ or higher

  1. for LED Headlight

    1. Disconnect the A62*1 or A8*2 front turn signal light connector.

      1. *1: for RH
      2. *2: for LH

    2. Disconnect the 3C instrument panel junction block assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open):
      for LH 
      Tester Connection
      Condition
      Specified Condition
      A8-1 (B) - 3C-28
      Always
      Below 1 Ω
      A8-2 (E) - Body ground
      Always
      Below 1 Ω
      for RH 
      Tester Connection
      Condition
      Specified Condition
      A62-1 (B) - 3C-38
      Always
      Below 1 Ω
      A62-2 (E) - Body ground
      Always
      Below 1 Ω


      Standard Resistance (Check for Short):
      for LH 
      Tester Connection
      Condition
      Specified Condition
      A8-1 (B) - Body ground
      Always
      10 kΩ or higher
      for RH 
      Tester Connection
      Condition
      Specified Condition
      A62-1 (B) - Body ground
      Always
      10 kΩ or higher

      Result:
      Result
      Proceed to
      NG
      A
      OK
      B



B
Go to step 6
A

REPAIR OR REPLACE HARNESS OR CONNECTOR 

4.CHECK HARNESS AND CONNECTOR (REAR COMBINATION LIGHT ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
  1. Disconnect the M6*1 or M5*2 rear turn signal light connector.

    1. *1: for RH
    2. *2: for LH

  1. Disconnect the 3D instrument panel junction block assembly connector.

  1. Measure the resistance according to the value(s) in the table below.


Standard Resistance (Check for Open):
for LH 
Tester Connection
Condition
Specified Condition
M5-5 (B) - 3D-18
Always
Below 1 Ω
M5-1 (E) - Body ground
Always
Below 1 Ω
for RH 
Tester Connection
Condition
Specified Condition
M6-5 (B) - 3D-5
Always
Below 1 Ω
M6-1 (E) - Body ground
Always
Below 1 Ω


Standard Resistance (Check for Short):
for LH 
Tester Connection
Condition
Specified Condition
M5-5 (B) - Body ground
Always
10 kΩ or higher
for RH 
Tester Connection
Condition
Specified Condition
M6-5 (B) - Body ground
Always
10 kΩ or higher

Result:
Result
Proceed to
NG
A
OK
B



B
Go to step 6
A

REPAIR OR REPLACE HARNESS OR CONNECTOR 

5.CHECK HARNESS AND CONNECTOR (OUTER REAR VIEW MIRROR ASSEMBLY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
  1. Disconnect the H7*1 or J7*2 outer rear view mirror assembly connector.

    1. *1: for RH
    2. *2: for LH

  1. Disconnect the 3B instrument panel junction block assembly connector.

  1. Measure the resistance according to the value(s) in the table below.


Standard Resistance (Check for Open):
for LH 
Tester Connection
Condition
Specified Condition
J7-2 (B) - 3B-38
Always
Below 1 Ω
J7-9 (-) - Body ground
Always
Below 1 Ω
for RH 
Tester Connection
Condition
Specified Condition
H7-2 (B) - 3B-39
Always
Below 1 Ω
H7-9 (-) - Body ground
Always
Below 1 Ω


Standard Resistance (Check for Short):
for LH 
Tester Connection
Condition
Specified Condition
J7-2 (B) - Body ground
Always
10 kΩ or higher
for RH 
Tester Connection
Condition
Specified Condition
H7-2 (B) - Body ground
Always
10 kΩ or higher

Result:
Result
Proceed to
NG
A
OK
B



B
Go to step 6
A

REPAIR OR REPLACE HARNESS OR CONNECTOR 

6.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY


  1. Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly (Click here).


    E237354E02

  1. Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection
Condition
Specified Condition
3B-25 - 3C-38
Always
Below 1 Ω
3B-25 - 3D-5
Always
Below 1 Ω
3B-25 - 3B-39
Always
Below 1 Ω
3B-24 - 3C-28
Always
Below 1 Ω
3B-24 - 3D-18
Always
Below 1 Ω
3B-24 - 3B-38
Always
Below 1 Ω

Text in Illustration 
*a
Component without harness connected
(Instrument Panel Junction Block Assembly)


NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (Click here)
OK

REPLACE COMBINATION METER ASSEMBLY (Click here)