Home › Engine / Hybrid System › 1NZ-FXE COOLING › COOLING FAN SYSTEM

COOLING FAN SYSTEM > PRECAUTION

for Preparation Click here



1.COOLING FAN SYSTEM

NOTICE:
  1. When the power switch is turned off and the engine temperature is high, the engine water pump assembly and cooling fans may operate for a maximum of 2 minutes depending on the auxiliary battery voltage..
  2. After turning the power switch off, keep hands and objects away from the fans when they are operating.

HINT:
If all of the following are met for a certain period of time during a few minutes immediately before the power switch is turned off, the cooling fans will continue to operate for a maximum of 2 minutes after the engine is stopped. This is performed to ensure restartability.
  1. The intelligent tester indicates a very high coolant temperature.
  1. The intelligent tester indicates a high outside air temperature.