Home › Power Source / Network › 1NZ-FXE BATTERY / CHARGING › CHARGING SYSTEM

CHARGING SYSTEM > ON-VEHICLE INSPECTION

for Preparation Click here



1. CHECK AUXILIARY BATTERY
  1. Check that the auxiliary battery cables are connected to the correct terminals.

    HINT:
    If they are not, connect them properly.

  1. Check the auxiliary battery for damage and deformation. If severe damage, deformation or leakage is found, replace the auxiliary battery.



2. CHECK AUXILIARY BATTERY VOLTAGE
  1. Turn the power switch off and turn on the high beam headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.

  1. Measure the auxiliary battery voltage according to the value(s) in the table below.

    Result:

    Tester Connection
    Condition
    Specified Condition
    Result
    Positive (+) terminal - Negative (-) terminal
    20°C (68°F), Power switch off
    12.5 V or higher
    Auxiliary battery is OK
    11.0 to 12.5 V
    Recharge auxiliary battery
    Below 11.0 V
    Replace auxiliary battery



3. RECHARGE AUXILIARY BATTERY
  1. Recharge the auxiliary battery.

    HINT:
    1. Recharge the auxiliary battery according to the charger's instructions.
    2. Apply the appropriate charging current according to the type of auxiliary battery as shown in the table below.
    Auxiliary Battery Type
    Charging Current
    S34B20R
    3 to 4 A

  1. Turn the power switch off and turn on the high beam headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.

  1. Measure the auxiliary battery voltage according to the value(s) in the table below.

    Result:

    Tester Connection
    Condition
    Specified Condition
    Result
    Positive (+) terminal - Negative (-) terminal
    20°C (68°F), Power switch off
    12.5 V or higher
    Auxiliary battery is OK
    11.0 to 12.5 V
    Recharge auxiliary battery
    Below 11.5 V
    Replace auxiliary battery



4. CHECK AUXILIARY BATTERY TERMINAL, FUSIBLE LINK AND FUSE
  1. Check that the auxiliary battery terminals are not loose or corroded.

    HINT:
    If the terminals are corroded, clean them.

  1. Measure the resistance of each fusible link and fuse for the auxiliary battery charging system.

    Standard resistance:
    Below 1 Ω

    HINT:
    If any of the results is not as specified, replace the fusible link or fuse as necessary.



5. CHECK AMD TERMINAL

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Check that the AMD terminal is connected securely, and there is no contact problem.

    HINT:
    If there are any arc marks, replace the affected parts.

  1. Check that the nuts for the AMD terminal is tightened to the specified torque.

    HINT:
    If there are no arc marks and the AMD terminal connection is faulty, connect the AMD terminal securely.

  1. Install the service plug grip.



6. CHECK DC/DC CONVERTER FUNCTION


    A174427E02
  1. Connect the AC/DC 400 A probe to the positive auxiliary battery cable.

  1. Turn the power switch on (READY) and leave the vehicle as it is until the electric current flowing into the auxiliary battery becomes 10 A or less.

  1. Turn the power switch on (READY) and the headlight position switch and blower motor switch in the HI position, and the rear window defogger turned on.



    A174428E02
  1. Measure the current and voltage according to the value(s) in the table below.

    Result:

    Item
    Tester Connection
    Condition
    Specified Condition
    Current flowing from auxiliary battery
    Auxiliary battery positive cable
    Power switch on (READY)
    (The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.)
    0 A or less
    (no current from auxiliary battery)
    Auxiliary battery voltage
    Positive (+) terminal - Negative (-) terminal
    13 to 15 V

    HINT:
    If the values are not as specified, replace the inverter with converter assembly.