Hybrid Battery Cooling Fan Performance Decrement
| History of "MAINTENANCE REQUIRED FOR HYBRID BATTERY COOLING PARTS AT YOUR DEALER" being displayed on the multi-information display.
| If "MAINTENANCE REQUIRED FOR HYBRID BATTERY COOLING PARTS AT YOUR DEALER" is displayed on the multi-information display, perform the following procedures.
- Make sure the air intake port is not blocked.
- Make sure there are no gaps between the connecting parts of the ducts.
- Clean the No. 1 hybrid battery intake filter. Check for entry of foreign matter.
Afterwards, clear the DTCs to reset the learning values even if no DTCs are stored.
|