Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM

HYBRID CONTROL SYSTEM > TERMINALS OF ECU

for Preparation Click here



C146689E57


Text in Illustration 
*1
Power Management Control ECU
-
-

Power management control ECU 
Terminal No.
(Symbol)
Wiring Color
Terminal Description
Condition
Specified Condition
A38-2 (+B2) - G57-6 (E1)
L - BR
Power source
Power switch on (IG)
11 to 14 V
A38-11 (VLO) - G57-6 (E1)
R - BR
DC/DC operation monitor / voltage change signal
Power switch on (IG)
Pulse generation
(Waveform 1)
A38-13 (IWP) - G57-6 (E1)
G - BR
Inverter water pump assembly signal
Power switch on (READY)
Pulse generation
(Waveform 2)
A38-14 (NIWP) - G57-6 (E1)
P - BR
Inverter water pump assembly signal
Power switch on (READY)
Pulse generation
(Waveform 2)
A38-15 (BL) - G57-6 (E1)
R - BR
Back up light
Power switch on (IG), shift lever in R
11 to 14 V
A38-19 (CLK) - G57-6 (E1)
G - BR
A/C communication signal
Power switch on (READY), air conditioning system stopped
Pulse generation
(Waveform 3)
A38-20 (STB) - G57-6 (E1)
W - BR
A/C communication signal
Power switch on (READY), air conditioning system stopped
Pulse generation
(Waveform 3)
A38-21 (NODD) - G57-6 (E1)
W - BR
DC/DC operation
DC/DC converter operating normally
5 to 7 V
DC/DC converter not operating normally
2 to 4 V
DC/DC converter operating prohibited
0.1 to 0.5 V
A38-24 (MMT) - A38-25 (MMTG)
L - BR
Motor temperature sensor
Power switch on (IG), temperature 25°C (77°F)
3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F)
2.2 to 3.2 V
A38-26 (GMT) - A38-27 (GMTG)
B - R
Generator temperature sensor
Power switch on (IG), temperature 25°C (77°F)
3.6 to 4.6 V
Power switch on (IG), temperature 60°C (140°F)
2.2 to 3.2 V
A38-29 (SI0) - G57-6 (E1)
Y - BR
HV battery blower fan operation signal
Power switch on (IG), during Active Test
Pulse generation
(Waveform 4)
A38-30 (ETI) - G57-6 (E1)
R - BR
A/C communication signal
Power switch on (READY), air conditioning system stopped
Pulse generation
(Waveform 3)
A38-31 (ITE) - G57-6 (E1)
Y - BR
A/C communication signal
Power switch on (READY), air conditioning system stopped
Pulse generation
(Waveform 3)
A38-32 (ILK) - G57-6 (E1)
V - BR
Interlock switch
Power switch on (IG), inverter terminal cover, high-voltage input cables and service plug grip installed correctly
0 to 1.5 V
Power switch on (IG), inverter terminal cover, high-voltage input cables or service plug grip not installed
11 to 14 V
A39-1 (IG2) - G57-6 (E1)
P - BR
Power source
Power switch on (IG)
11 to 14 V
A39-2 (IG2D) - G57-6 (E1)
P - BR
IG2 relay
Power switch on (IG)
11 to 14 V
A39-5 (+B1) - G57-6 (E1)
L - BR
Power source
Power switch on (IG)
11 to 14 V
A39-6 (MREL) - G57-6 (E1)
BE - BR
Main relay
Power switch on (IG)
11 to 14 V
A39-7 (ST1-) - G57-6 (E1)
BR - BR
Brake cancel switch
Power switch on (IG), brake pedal depressed
0 to 1.5 V
Power switch on (IG), brake pedal released
11 to 14 V
A39-8 (N) - G57-6 (E1)
Y - BR
Shift lever position signal
Power switch on (IG), shift lever in N
11 to 14 V
Power switch on (IG), shift lever not in N
0.5 to 1.5 V
A39-9 (PR) - G57-6 (E1)
V - BR
Shift lever position signal
Power switch on (IG), shift lever in P or R
11 to 14 V
Power switch on (IG), shift lever not in P or R
0.5 to 1.5 V
A39-11 (DB1) - G57-6 (E1)
L - BR
Shift lever position signal
Power switch on (IG), shift lever in D or B
11 to 14 V
Power switch on (IG), shift lever not in D or B
0.5 to 1.5 V
A39-13 (DB2) - G57-6 (E1)
B - BR
Shift lever position signal
Power switch on (IG), shift lever in D or B
11 to 14 V
Power switch on (IG), shift lever not in D or B
0.5 to 1.5 V
A39-14 (R) - G57-6 (E1)
SB - BR
Shift lever position signal
Power switch on (IG), shift lever in R
11 to 14 V
Power switch on (IG), shift lever not in R
0.5 to 1.5 V
A39-15 (P) - G57-6 (E1)
BE - BR
Shift lever position signal
Power switch on (IG), shift lever in P
11 to 14 V
Power switch on (IG), shift lever not in P
0.5 to 1.5 V
A39-16 (PNB) - G57-6 (E1)
G - BR
Shift lever position signal
Power switch on (IG), shift lever in P, N or B
11 to 14 V
A39-18 (VCP1) - A39-34 (EP1)
Y - B
Accelerator pedal sensor assembly power source (for VPA1)
Power switch on (IG)
4.5 to 5.5 V
A39-19 (VCP2) - A39-35 (EP2)
G - R
Accelerator pedal sensor assembly power source (for VPA2)
Power switch on (IG)
4.5 to 5.5 V
A39-20 (CLK-) - G57-6 (E1)
W - BR
MG communication clock signal
Power switch on (READY)
Pulse generation
(Waveform 5)
A39-21 (CLK+) - G57-6 (E1)
B - BR
MG communication clock signal
Power switch on (READY)
Pulse generation
(Waveform 5)
A39-23 (STP) - G57-6 (E1)
L - BR
Stop light switch
Brake pedal depressed
11 to 14 V
Brake pedal released
0 to 1.5 V
A39-24 (HTM+) - G57-6 (E1)
B - BR
Communication signal from power management control ECU to MG ECU
Power switch on (IG)
Pulse generation
(Waveform 6)
A39-25 (HTM-) - G57-6 (E1)
W - BR
Communication signal from power management control ECU to MG ECU
Power switch on (IG)
Pulse generation
(Waveform 6)
A39-26 (VPA1) - A39-34 (EP1)
L - B
Accelerator pedal sensor assembly (for accelerator pedal position detection)
Power switch on (IG), accelerator pedal released
0.4 to 1.4 V
Power switch on (IG) engine stopped, shift lever in P accelerator pedal fully depressed
2.6 to 4.5 V
A39-27 (VPA2) - A39-35 (EP2)
W - R
Accelerator pedal sensor assembly (for accelerator pedal position detection)
Power switch on (IG), accelerator pedal released
1.0 to 2.2 V
Power switch on (IG) engine stopped, shift lever in P accelerator pedal fully depressed
3.4 to 5.3 V
A39-29 (MTH-) - G57-6 (E1)
W - BR
Communication signal from MG ECU to power management control ECU
Power switch on (IG)
Pulse generation
(Waveform 7)
A39-30 (MTH+) - G57-6 (E1)
B - BR
Communication signal from MG ECU to power management control ECU
Power switch on (IG)
Pulse generation
(Waveform 7)
A39-31 (HSDN) - G57-6 (E1)
B - BR
MG ECU shutdown signal
Power switch on (READY)
0 to 1.5 V
A39-32 (REQ-) - G57-6 (E1)
W - BR
MG ECU communication request signal
Power switch on (IG)
Pulse generation
(Waveform 8)
A39-33 (REQ+) - G57-6 (E1)
B - BR
MG ECU communication request signal
Power switch on (IG)
Pulse generation
(Waveform 8)
G57-1 (AM22) - G57-6 (E1)
B - BR
Constant power source
Power switch on (IG)
11 to 14 V
Power switch on (READY)
11 to 15.5 V
G57-2 (SMRG) - G57-5 (E01)
Y - W-B
System main relay operation signal
Power switch on (IG)→Power switch on (READY)
Pulse generation
(Waveform 9)
G57-3 (SMRP) - G57-5 (E01)
W - W-B
System main relay operation signal
Power switch on (IG)→Power switch on (READY)
Pulse generation
(Waveform 9)
G57-4 (SMRB) - G57-5 (E01)
SB - W-B
System main relay operation signal
Power switch on (IG)→Power switch on (READY)
Pulse generation
(Waveform 9)
G57-7 (SSW1) - G57-6 (E1)
V - BR
Power switch
Power switch pressed and held
0 to 1.5 V
G57-11 (TC) - G57-6 (E1)
V - BR
Diagnosis terminal
Power switch on (IG)
11 to 14 V
G57-13 (EVSW) - G57-6 (E1)
B - BR
EV switch signal
Power switch on (IG), EV switch not operated
11 to 14 V
Power switch on (IG), EV switch operated
0 to 1.5 V
G57-14 (SPDI) - G57-6 (E1)
SB - BR
Vehicle speed signal
Driving at approximately 20 km/h (12 mph) with power switch on (READY)
Pulse generation
(Waveform 10)
G57-15 (P2) - G57-6 (E1)
G - BR
Shift P signal
Power switch on (IG)
(Waveform 11)
G57-28 (THB) - G57-30 (ETHB)
L - V
Auxiliary battery temperature
Power switch on (IG), auxiliary battery temperature 25°C (77°F)
1.7 to 2.3 V
Power switch on (IG), auxiliary battery temperature 60°C (140°F)
0.6 to 0.9 V
G57-29 (ABFS) - G57-6 (E1)
R - BR
Airbag activation signal
Power switch on (READY)
Pulse generation
(Waveform 12)
G57-32 (BTH+) - G57-6 (E1)
R - BR
Communication signal from battery smart unit to power management control ECU
Power switch on (IG)
Pulse generation
(Waveform 13)
G57-33 (BTH-) - G57-6 (E1)
G - BR
Communication signal from battery smart unit to power management control ECU
Power switch on (IG)
Pulse generation
(Waveform 13)
G58-1 (ACCD) - G57-6 (E1)
L - BR
ACC relay
Power switch on (ACC)
11 to 14 V
G58-2 (IG1D) - G57-6 (E1)
SB - BR
IG1 relay
Power switch on (IG)
11 to 14 V
G58-7 (AM21) - G57-6 (E1)
B - BR
Constant power source
Power switch on (IG)
11 to 14 V
Power switch on (READY)
11 to 15.5 V
G58-11 (LIN2) - G57-6 (E1)
LG - BR
LIN communication signal
Power switch on (IG)
Pulse generation
G58-17 (SSW2) - G57-6 (E1)
SB - BR
Power switch
Power switch pressed and held
0 to 1.5 V
G58-24 (CA1L) - G57-6 (E1)
W - BR
CAN communication signal
Power switch on (IG)
Pulse generation
(Waveform 14)
G58-25 (CA1H) - G57-6 (E1)
BE - BR
CAN communication signal
Power switch on (IG)
Pulse generation
(Waveform 14)
G58-30 (CA3N) - G57-6 (E1)
W - BR
CAN communication signal
Power switch on (IG)
Pulse generation
(Waveform 15)
G58-31 (CA3P) - G57-6 (E1)
R - BR
CAN communication signal
Power switch on (IG)
Pulse generation
(Waveform 15)

Oscilloscope waveforms

HINT:
Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.



    A217985E01
  1. Waveform 1 (DC/DC operation monitor / voltage change signal)
    Item
    Content
    Terminal
    A38-11 (VLO) - G57-6 (E1)
    Equipment Setting
    5 V/DIV., 50 ms./DIV.
    Condition
    Power switch on (IG)

    HINT:
    The cycle will vary depending on the specified voltage of the hybrid vehicle converter.



  2. C206008E03
  3. Waveform 2 (Inverter water pump assembly signal)
    Item
    Content
    Terminal
    CH1: A38-13 (IWP) - G57-6 (E1)
    CH2: A38-14 (NIWP) - G57-6 (E1)
    Equipment Setting
    5 V/DIV., 50 ms./DIV.
    Condition
    Power switch on (READY)



  4. A111607E01
  5. Waveform 3 (A/C communication signal)
    Item
    Content
    Terminal
    CH1: A38-19 (CLK) - G57-6 (E1)
    CH2: A38-31 (ITE) - G57-6 (E1)
    CH3: A38-30 (ETI) - G57-6 (E1)
    CH4: A38-20 (STB) - G57-6 (E1)
    Equipment Setting
    10 V/DIV., 100 ms./DIV.
    Condition
    Power switch on (READY), air conditioning system stopped

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).



  6. A256953E01
  7. Waveform 4 (HV battery blower fan operation signal)
    Item
    Content
    Terminal
    A38-29 (SI0) - G57-6 (E1)
    Equipment Setting
    5 V/DIV., 500 ms./DIV.
    Condition
    Power switch on (IG), during Active Test

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).



  8. A111604E01
  9. Waveform 5 (MG communication clock signal)
    Item
    Content
    Terminal
    CH1: A39-21 (CLK+) - G57-6 (E1)
    CH2: A39-20 (CLK-) - G57-6 (E1)
    Equipment Setting
    1 V/DIV., 1 μs./DIV.
    Condition
    Power switch on (READY)



  10. A114529E01
  11. Waveform 6 (communication signal from power management control ECU to MG ECU)
    Item
    Content
    Terminal
    CH1: A39-24 (HTM+) - G57-6 (E1)
    CH2: A39-25 (HTM-) - G57-6 (E1)
    Equipment Setting
    1 V/DIV., 200 μs./DIV.
    Condition
    Power switch on (IG)

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).



  12. A114529E01
  13. Waveform 7 (communication signal from MG ECU to power management control ECU)
    Item
    Content
    Terminal
    CH1: A39-30 (MTH+) - G57-6 (E1)
    CH2: A39-29 (MTH-) - G57-6 (E1)
    Equipment Setting
    1 V/DIV., 200 μs./DIV.
    Condition
    Power switch on (IG)

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).



  14. A111605E01
  15. Waveform 8 (MG ECU communication request signal)
    Item
    Content
    Terminal
    CH1: A39-33 (REQ+) - G57-6 (E1)
    CH2: A39-32 (REQ-) - G57-6 (E1)
    Equipment Setting
    1 V/DIV., 1 ms./DIV.
    Condition
    Power switch on (IG)



  16. C206010E02
  17. Waveform 9 (system main relay operation signal)
    Item
    Content
    Terminal
    CH1: G57-3 (SMRP) - G57-5 (E01)
    CH2: G57-4 (SMRB) - G57-5 (E01)
    CH3: G57-2 (SMRG) - G57-5 (E01)
    Equipment Setting
    10 V/DIV., 200 ms./DIV.
    Condition
    Power switch on (IG) → Power switch on (READY)



  18. A111593E03
  19. Waveform 10 (vehicle speed signal)
    Item
    Content
    Terminal
    G57-14 (SPDI) - G57-6 (E1)
    Equipment Setting
    5 V/DIV., 20 ms./DIV.
    Condition
    Driving at approximately 20 km/h (12 mph) with power switch on (READY)

    HINT:
    The higher the vehicle speed, the shorter the cycle.



  20. A279004E01
  21. Waveform 11 (shift P signal)
    Item
    Content
    Terminal
    G57-15 (P2) - G57-6 (E1)
    Equipment Setting
    5 V/DIV., 10 ms./DIV.
    Condition
    Power switch on (IG)



  22. A111590E01
  23. Waveform 12 (airbag activation signal)
    Item
    Content
    Terminal
    G57-29 (ABFS) - G57-6 (E1)
    Equipment Setting
    5 V/DIV., 500 ms./DIV.
    Condition
    Power switch on (READY)



  24. A111597E01
  25. Waveform 13 (communication signal from battery smart unit to power management control ECU)
    Item
    Content
    Terminal
    CH1: G57-32 (BTH+) - G57-6 (E1)
    CH2: G57-33 (BTH-) - G57-6 (E1)
    Equipment Setting
    2 V/DIV., 500 μs./DIV.
    Condition
    Power switch on (IG)

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).



  26. A111598E01
  27. Waveform 14 (CAN communication signal)
    Item
    Content
    Terminal
    CH1: G58-25 (CA1H) - G57-6 (E1)
    CH2: G58-24 (CA1L) - G57-6 (E1)
    Equipment Setting
    1 V/DIV., 50 μs./DIV.
    Condition
    Power switch on (IG)

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).



  28. A111598E01
  29. Waveform 15 (CAN communication signal)
    Item
    Content
    Terminal
    CH1: G58-31 (CA3P) - G57-6 (E1)
    CH2: G58-30 (CA3N) - G57-6 (E1)
    Equipment Setting
    1 V/DIV., 50 μs./DIV.
    Condition
    Power switch on (IG)

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).


A216756E09


Text in Illustration 
*1
Inverter with Converter Assembly
-
-

HINT:
Since the inverter with converter assembly uses waterproof connectors, the voltage and waveform cannot be inspected directly. Standard voltage readings and waveforms are indicated for reference only.


Inverter with converter assembly 
Terminal No.
(Symbol)
Wiring Color
Terminal Description
Condition
Standard Condition
A47-1 (IGCT) - A47-28 (GND1)
B - W
MG ECU power source
Power switch on (IG)
11 to 14 V
A47-3 (VLO) - A47-28 (GND1)
R - W
DC/DC operation monitor / voltage change signal
Power switch on (IG)
Pulse generation
(Waveform 1)
A47-5 (CLK+) - A47-28 (GND1)
B - W
MG ECU communication clock signal
Power switch on (READY)
Pulse generation
(Waveform 2)
A47-6 (REQ+) - A47-28 (GND1)
B - W
MG ECU communication request signal
Power switch on (READY)
Pulse generation
(Waveform 3)
A47-7 (MTH+) - A47-28 (GND1)
B - W
Communication signal from MG ECU to power management control ECU
Power switch on (READY)
Pulse generation
(Waveform 4)
A47-8 (HTM+) - A47-28 (GND1)
B - W
Communication signal from power management control ECU to MG ECU
Power switch on (READY)
Pulse generation
(Waveform 5)
A47-9 (+B2) - A47-28 (GND1)
G - W
MG ECU power source
Power switch on (IG)
11 to 14 V
A47-10 (+B) - A47-28 (GND1)
G - W
MG ECU power source
Power switch on (IG)
11 to 14 V
A47-12 (NODD) - A47-28 (GND1)
W - W
DC/DC operation
DC/DC converter operating normally
5 to 7 V
DC/DC converter not operating normally
2 to 4 V
DC/DC converter operation prohibited
0.1 to 0.5 V
A47-15 (CLK-) - A47-28 (GND1)
W - W
MG ECU communication clock signal
Power switch on (READY)
Pulse generation
(Waveform 2)
A47-16 (REQ-) - A47-28 (GND1)
W - W
MG ECU communication request signal
Power switch on (READY)
Pulse generation
(Waveform 3)
A47-17 (MTH-) - A47-28 (GND1)
W - W
Communication signal from MG ECU to power management control ECU
Power switch on (READY)
Pulse generation
(Waveform 4)
A47-18 (HTM-) - A47-28 (GND1)
W - W
Communication signal from power management control ECU to MG ECU
Power switch on (READY)
Pulse generation
(Waveform 5)
A47-29 (GI) - A47-28 (GND1)
B - W
Camshaft position sensor signal
Power switch on (READY), with engine running
Pulse generation
(Waveform 6)
A47-31 (HSDN) - A47-28 (GND1)
B - W
MG shutdown signal
Power switch on (READY)
0 to 1 V
A47-35 (ILKI) - A47-28 (GND1)
V - W
Interlock switch signal
Power switch on (IG), inverter terminal cover, high-voltage input cables and service plug grip installed correctly
Below 1 V
Power switch on (IG), inverter terminal cover, high-voltage input cables or service plug grip not installed
11 to 14
A47-36 (ILKO) - A47-28 (GND1)
LG - W
Interlock switch signal
Power switch on (IG), inverter terminal cover, high-voltage input cables and service plug grip installed correctly
Below 1 V
Power switch on (IG), inverter terminal cover, high-voltage input cables or service plug grip not installed
11 to 14
C28-1 (MRF) - C28-2 (MRFG)
BR - G
Motor resolver signal
Motor resolver running
Pulse generation
(Waveform 7)
C28-3 (MSN) - C28-4 (MSNG)
L - R
Motor resolver signal
Motor resolver running
Pulse generation
(Waveform 7)
C28-6 (MCS) - C28-5 (MCSG)
W - Y
Motor resolver signal
Motor resolver running
Pulse generation
(Waveform 7)
C28-7 (GSN) - C28-8 (GSNG)
L - R
Generator resolver signal
Generator resolver running
Pulse generation
(Waveform 8)
C28-10 (GCS) - C28-9 (GCSG)
W - Y
Generator resolver signal
Generator resolver running
Pulse generation
(Waveform 8)
C28-11 (GRF) - C28-12 (GRFG)
BR - G
Generator resolver signal
Generator resolver running
Pulse generation
(Waveform 8)

NOTICE:
Do not measure the voltage or waveform directly at the sealed side of the inverter with converter assembly connector. Doing so may damage the connector because the connector is waterproof.


Oscilloscope waveforms

HINT:
Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.



    A217985E01
  1. Waveform 1 (DC/DC operation monitor / voltage change signal)
    Item
    Content
    Terminal
    A47-3 (VLO) - A47-28 (GND1)
    Equipment Setting
    5 V/DIV., 50 ms./DIV.
    Condition
    Power switch on (IG)

    HINT:
    The cycle will vary depending on the specified voltage of the hybrid vehicle converter.



  2. A111604E01
  3. Waveform 2 (MG ECU communication clock signal)
    Item
    Content
    Terminal
    CH1: A47-5 (CLK+) - A47-28 (GND1)
    CH2: A47-15 (CLK-) - A47-28 (GND1)
    Equipment Setting
    1 V/DIV., 1 μs./DIV.
    Condition
    Power switch on (READY)



  4. A111605E01
  5. Waveform 3 (MG ECU communication request signal)
    Item
    Content
    Terminal
    CH1: A47-6 (REQ+) - A47-28 (GND1)
    CH2: A47-16 (REQ-) - A47-28 (GND1)
    Equipment Setting
    1 V/DIV., 1 ms./DIV.
    Condition
    Power switch on (READY)



  6. A114529E01
  7. Waveform 4 (communication signal from MG ECU to power management control ECU)
    Item
    Content
    Terminal
    CH1: A47-7 (MTH+) - A47-28 (GND1)
    CH2: A47-17 (MTH-) - A47-28 (GND1)
    Equipment Setting
    1 V/DIV., 200 μs./DIV.
    Condition
    Power switch on (READY)

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).



  8. A114529E01
  9. Waveform 5 (communication signal from power management control ECU to MG ECU)
    Item
    Content
    Terminal
    CH1: A47-8 (HTM+) - A47-28 (GND1)
    CH2: A47-18 (HTM-) - A47-28 (GND1)
    Equipment Setting
    1 V/DIV., 200 μs./DIV.
    Condition
    Power switch on (READY)

    HINT:
    The waveform will vary depending on the content of the digital communication (digital signal).



  10. A217984E01
  11. Waveform 6 (Camshaft position sensor signal)
    Item
    Content
    Terminal
    A47-29 (GI) - A47-28 (GND1)
    Equipment Setting
    5 V/DIV., 20 ms./DIV.
    Condition
    Power switch on (READY), with engine running

    HINT:
    The pulse cycle becomes shorter as the engine speed increases.



  12. A111610E01
  13. Waveform 7 (motor resolver signal)
    Item
    Content
    Terminal
    CH1: C28-1 (MRF) - C28-2 (MRFG)
    CH2: C28-3 (MSN) - C28-4 (MSNG)
    CH3: C28-6 (MCS) - C28-5 (MCSG)
    Equipment Setting
    CH1: 10 V/DIV., 1 ms./DIV.
    CH2, 3: 5 V/DIV., 1 ms./DIV.
    Condition
    Motor resolver running

    HINT:
    Pulse cycle A becomes shorter as the rotor speed increases.



  14. A111610E01
  15. Waveform 8 (generator resolver signal)
    Item
    Content
    Terminal
    CH1: C28-11 (GRF) - C28-12 (GRFG)
    CH2: C28-7 (GSN) - C28-8 (GSNG)
    CH3: C28-10 (GCS) - C28-9 (GCSG)
    Equipment Setting
    CH1: 10 V/DIV., 1 ms./DIV.
    CH2, 3: 5 V/DIV., 1 ms./DIV.
    Condition
    Generator resolver running

    HINT:
    Pulse cycle A becomes shorter as the rotor speed increases.