HYBRID CONTROL SYSTEM > DATA LIST / ACTIVE TEST |
| DATA LIST |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Powertrain / Hybrid Control / Data List.
Check the results by referring to the following table.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Engine Coolant Temp | Engine coolant temperature/ Min.: -40°C (-40°F), Max.: 215°C (419°F) | Cold start→Fully warmed up: Gradually rises After warming up: 75 to 100°C (167 to 212°F) | - |
| Engine Revolution | Engine speed/ Min.: 0 rpm, Max.: 16383 rpm | While idling after the engine is warmed up and inspection mode: Approximately 900 rpm While driving at a constant speed: No significant fluctuation | - |
| Vehicle Spd | Vehicle speed/ Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph) | Vehicle stopped: 0 km/h (0 mph) While driving at a constant speed: No significant fluctuation | - |
| Engine Run Time | Elapsed time after starting engine/ Min.: 0 s, Max.: 65535 s | Elapsed time after starting engine | After the power switch is turned on (READY), elapsed time from initial engine start until the power switch is turned off. |
| +B | Auxiliary battery voltage/ Min.: 0.00 V, Max.: 65.53 V | Constant: 10.00 to 15.00 V | Auxiliary battery condition |
| Accel Pedal Pos #1 | Accelerator pedal position sensor No.1/ Min.: 0.0%, Max.: 100.0% | Accelerator pedal depressed: Changes with accelerator pedal pressure | Accelerator pedal sensor assembly |
| Accel Pedal Pos #2 | Accelerator pedal position sensor No.2/ Min.: 0.0%, Max.: 100.0% | Accelerator pedal depressed: Changes with accelerator pedal pressure | Accelerator pedal sensor assembly |
| Ambient Temperature | Ambient air temperature/ Min.: -40°C (-40°F), Max.: 215°C (419°F) | Power switch on (IG): Same as ambient air temperature | Ambient temperature sensor |
| Intake Air Temperature | Intake air temperature/ Min.: -40°C (-40°F), Max.: 140°C (284°F) | Constant: Same as ambient air temperature | - |
| DTC Clear Warm Up | The number of times the engine is warmed up after clearing DTCs/ Min.: 0, Max.: 255 | MIL OFF, engine coolant temperature increases from below 22°C (71.6°F) before starting the engine to above 70°C (158°F) after starting the engine: Increases once | - |
| DTC Clear Run Distance | Drive distance after clearing DTCs/ Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) | - | - |
| DTC Clear Min | Elapsed time after clearing DTCs/ Min.: 0 min, Max.: 65535 min | - | - |
| MIL on Engine Run Time | Driving time after a malfunction occurs/ Min.: 0 min, Max.: 65535 min | - | - |
| MIL Status | MIL status/ ON or OFF | MIL ON: ON | Constant ON: Repair in accordance with detected DTCs |
| MIL on Run Distance | Travel distance after a malfunction occurs/ Min.: 0 km (0 mile), Max.: 65535 km (40723 mile) | - | - |
| Engine Code | Engine code | P510 | - |
| ECU Code | ECU code | - | - |
| Destination | Destination | Q | - |
| OBD Requirements | OBD requirements | E-OBD | - |
| MAP | Intake manifold pressure/ Min.: 0 kPa, Max.: 255 kPa | Power switch on (IG) or engine stopped: Atmosphere pressure | Valued less than atmospheric pressure are indicated while the engine is running |
| Atmosphere Pressure | Atmospheric pressure/ Min.: 0 kPa, Max.: 255 kPa | Constant: Atmosphere pressure | - |
| Number of Emission DTC | The number of emission DTCs | - | - |
| Ready Signal | Power switch condition/ ON or OFF | Power switch on (READY): ON | - |
| Motor(MG2) Revolution | MG2 revolution/ Min.: -32768 rpm, Max.: 32767 rpm | While driving: Varies depending on vehicle operating conditions |
|
| Motor(MG2) Torq | MG2 torque/ Min.: -4096.00 Nm, Max.: 4095.87 Nm | While driving: Varies depending on vehicle operating conditions |
|
| M(MG2) Trq Exec Val | MG2 torque execution value/ Min.: -4096.00 Nm, Max.: 4095.87 Nm | After full-load acceleration with power switch on (READY) and engine stopped: Less than +/-20% of MG2 torque |
|
| Generator(MG1) Rev | MG1 revolution/ Min.: -32768 rpm, Max.: 32767 rpm | During charge or discharge: Varies depending on vehicle operating conditions |
|
| Generator(MG1) Torq | MG1 torque/ Min.: -4096.00 Nm, Max.: 4095.87 Nm | During charge or discharge: Varies depending on vehicle operating conditions |
|
| G(MG1) Trq Exec Val | MG1 torque execution value/ Min.: -4096.00 Nm, Max.: 4095.87 Nm | One second after engine automatically starts with shift lever in P (Condition before engine start: Power switch on (READY), engine stopped, A/C fan speed high and headlights on): Less than +/- 20% of MG1 torque |
|
| Regenerative Brake Torq | MG1 regenerative braking execution torque/ Min.: -4096.0 Nm, Max.: 4095.0 Nm | While braking: Varies depending on vehicle operation conditions |
|
| Rqst Regen Brake Torq | Requested MG1 regenerative braking torque/ Min.: -4096.0 Nm, Max.: 4095.0 Nm | While braking: Varies depending on vehicle operation conditions |
|
| Inverter Temp-(MG1) | Generator inverter temperature/ Min.: 15°C (59°F), Max.: 150°C (302°F) | Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 15 to 35°C (59 to 95°F) While driving at an ambient temperature of 25°C (77°F): 15 to 110°C (59 to 230°F) | Inverter with converter assembly |
| Inverter Temp-(MG2) | Motor inverter temperature/ Min.: 15°C (59°F), Max.: 150°C (302°F) | Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 15 to 35°C (59 to 95°F) While driving at an ambient temperature of 25°C (77°F): 15 to 110°C (59 to 230°F) | Inverter with converter assembly |
| Motor Temp No2 | MG1 temperature/ Min.: -40°C (-40°F), Max.: 215°C (419°F) | Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 25°C (77°F) While driving at an ambient temperature of 25°C (77°F): 25 to 100°C (77 to 212°F) | GMT terminal |
| Motor Temp No1 | MG2 temperature/ Min.: -40°C (-40°F), Max.: 215°C (419°F) | Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 25°C (77°F) While driving at an ambient temperature of 25°C (77°F): 25 to 90°C (77 to 194°F) | MMT terminal |
| Accelerator Degree | Accelerator pedal depressed angle/ Min.: 0.0%, Max.: 100.0% | Accelerator pedal depressed: Changes with accelerator pedal pressure | Accelerator pedal sensor assembly |
| Request Power | Request engine power/ Min.: 0 W, Max.: 655350 W | While driving with the engine running: Varies depending on vehicle operating conditions |
|
| Target Engine Rev | Target engine speed/ Min.: 0 rpm, Max.: 65535 rpm | While driving with the engine running: Varies depending on vehicle operating conditions |
|
| Total Distance Traveled | Drive total distance/ Min.: 0 km (0 mile), Max.: 16777215 km (10425361 mile) | - | - |
| State of Charge (All Bat) | HV battery state of charge/ Min.: 0.0%, Max.: 100.0% | Constant: 0.0 to 100.0% |
|
| Master Cylinder Ctrl Trq | Master cylinder control torque/ Min.: -4096.0 Nm, Max.: 4095.0 Nm | Brake pedal depressed: Changes with the brake pedal pressure | Master cylinder pressure sensor |
| Power Resource VB | HV battery voltage/ Min.: 0.0 V, Max.: 6553.5 V | Power switch on (READY): 150.0 to 300.0 V |
|
| Power Resource IB | HV battery current/ Min.: -327.68 A, Max.: 327.67 A | Power switch on (READY): -200.00 to 200.00 A |
|
| VL-Voltage before Boosting | High voltage before it is boosted/ Min.: 0 V, Max.: 450 V | Power switch on (READY): Practically the same as the HV battery voltage |
|
| VH-Voltage after Boosting | High voltage after it is boosted/ Min.: 0 V, Max.: 1000 V | Engine revving up with shift lever in P: After boosted voltage to below 650 V | Inverter with converter assembly |
| Boost Ratio | Boost converter boost ratio/ Min.: 0.0%, Max.: 127.5% | The pre-boost and the post boost voltages are equal: 0.0 to 10.0% | Inverter with converter assembly |
| Drive Condition ID | Drive condition ID |
|
|
| Shift Sensor Shift Pos | Shift position/ P/R/N/D/B | Matches currently selected shift position: P, R, N, D or B | Shift lever position sensor |
| Crank Position | Crankshaft position/ Min.: -128 °CA, Max.: 127 °CA | - | - |
| A/C Consumption Pwr | A/C consumption power/ Min.: 0 W, Max.: 12750 W | While the air conditioning system is operating: 0 to 5000 W | Air conditioning system |
| Short Wave Highest Val | Waveform voltage in leak detection circuit in battery smart unit/ Min.: 0.00 V, Max.: 4.98 V | Left for 2 minutes in power switch on (READY), and pre-boost and post boost voltages are equal: 4.00 V or more | High voltage circuit |
| MG1 Control Mode | MG1 control mode/ Min.: 0, Max.: 2 | PWM: 0 Variable PWM: 1 Rectangular wave: 2 | - |
| MG1 Carrier Frequency | MG1 carrier frequency/ 0.75kHz/1.25kHz/2.50kHz/3.75kHz/5.00kHz/10.00kHz | - | - |
| MG2 Control Mode | MG2 control mode/ Min.: 0, Max.: 2 | PWM: 0 Variable PWM: 1 Rectangular wave: 2 | - |
| MG2 Carrier Frequency | MG2 carrier frequency/ 0.75kHz/1.25kHz/2.50kHz/3.75kHz/5.00kHz | - | - |
| Num of Current Code | The number of current DTCs/ Min.: 0, Max.: 255 | - | - |
| Num of History Code | The number of history DTCs/ Min.: 0, Max.: 255 | - | - |
| Check Mode | Check Mode/ ON or OFF | - | - |
| Shift Sensor SW - P | Shift lever position sensor/ ON or OFF | Shift lever in P: ON Shift lever in any position other than P: OFF | Shift lever position sensor |
| Shift Sensor SW - R | Shift lever position sensor/ ON or OFF | Shift lever in R: ON Shift lever in any position other than R: OFF | Shift lever position sensor |
| Shift Sensor SW - PR | Shift lever position sensor/ ON or OFF | Shift lever in P or R: ON Shift lever in any position other than P or R: OFF | Shift lever position sensor |
| Shift Sensor SW - N | Shift lever position sensor/ ON or OFF | Shift lever in N: ON Shift lever in any position other than N: OFF | Shift lever position sensor |
| Shift Sensor SW - DB1 | Shift lever position sensor/ ON or OFF | Shift lever in D or B: ON Shift lever in any position other than D: OFF | Shift lever position sensor |
| Shift Sensor SW - DB2 | Shift lever position sensor/ ON or OFF | Shift lever in D or B: ON Shift lever in any position other than B: OFF | Shift lever position sensor |
| Shift Sensor SW - PNB | Shift lever position sensor/ ON or OFF | Shift lever in P, N or B: ON Shift lever in any position other than P, N or B: OFF | Shift lever position sensor |
| Calculate Load | Calculated load/ Min.: 0.0%, Max.: 100.0% | Engine idling with warm engine, air conditioner off, shift lever in P and inspection mode selected: 20.0 to 40.0% Engine speed of 2500 rpm, air conditioner off, shift lever in P and inspection mode selected: 15.0 to 35.0% |
|
| Throttle Position | Throttle position sensor/ Min.: 0.0%, Max.: 100.0% | Throttle valve fully closed: 10.0 to 24.0% | Throttle valve status |
| DCDC Cnv Tar Pulse Duty | Target auxiliary battery voltage/ Min.: 0.0%, Max.: 399.9% | - | - |
| Inverter Coolant Water Temperature | Inverter coolant temperature/ Min.: -40°C (-40°F), Max.: 110°C (230°F) | Cold start→Fully warmed up: Gradually rises System operating normally: Controlled at 65°C (149°F) or less |
|
| Cooling Fan 0 | Cooling fan operating condition/ Min.: 0.0%, Max.: 127.5% | - | - |
| Inverter W/P Revolution | Inverter water pump assembly speed/ Min.: 0 rpm, Max.: 15000 rpm | Power switch on (READY): 1625 to 5875 rpm |
|
| Prohibit DC/DC conv sig | DC/DC converter prohibition signal/ ON or OFF | Power switch on (IG): ON (Prohibited) Power switch on (READY): OFF (Permitted) |
|
| EV Request | EV drive mode transition availability/ ON or OFF | In EV drive mode: ON | - |
| TRC OFF Switch | VSC condition/ OFF / TRC / TRC/VSC | VSC OFF switch on: OFF | - |
| Starter Switch | Starter ON / OFF signal/ ON or OFF | - | - |
| Inv-T (MG1) aftr IG-ON | Generator inverter temperature soon after power switch on (IG)/ Min.: 15°C (59°F), Max.: 150°C (302°F) | - | - |
| Inv-T (MG2) aftr IG-ON | Motor inverter temperature soon after power switch on (IG)/ Min.: 15°C (59°F), Max.: 150°C (302°F) | - | - |
| Mtr-T (MG2) aftr IG-ON | MG2 temperature soon after power switch on (IG)/ Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Conv-Tmp after IG-ON | Boost converter temperature soon after power switch on (IG)/ Min.: 15°C (59°F), Max.: 150°C (302°F) | - | - |
| SOC after IG-ON | HV battery state of charge soon after power switch on (IG)/ Min.: 0.0%, Max.: 127.5% | - | - |
| Inv-Temp (MG1) Max | Generator inverter maximum temperature/ Min.: 15°C (59°F), Max.: 150°C (302°F) | - | - |
| Inv-Temp (MG2) Max | Motor inverter maximum temperature/ Min.: 15°C (59°F), Max.: 150°C (302°F) | - | - |
| Mtr-Temp (MG2) Max | MG2 maximum temperature/ Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Converter Temp Max | Boost converter maximum temperature/ Min.: 15°C(59°F), Max.: 150°C (302°F) | - | - |
| Status of Charge Max | Maximum status of charge/ Min.: 0.0%, Max.: 127.5% | - | - |
| Status of Charge Min | Minimum status of charge/ Min.: 0.0%, Max.: 127.5% | - | - |
| Stop Light Switch | Stop light switch assembly condition/ ON or OFF | Brake pedal depressed: ON | - |
| Auxiliary Batt Temperature | Auxiliary battery temperature/ Min.: -40°C (-40°F), Max.: 215°C (419°F) | Auxiliary battery temperature is 20°C (68°F): 20°C (68°F) | - |
| Collision Signal (Airbag) | Detection of collision by airbag sensor assembly/ ON or OFF | Collision detection by the airbag sensor assembly: ON | - |
| TC Terminal | TC terminal state/ ON or OFF | TC terminal connected: ON | - |
| Inter Lock Switch | Interlock switch condition/ ON or OFF | Power switch on (IG), inverter terminal cover, frame wire and service plug grip installed detached: ON | - |
| EV Switch | EV drive mode switch (integration control and panel sub-assembly) condition/ ON or OFF | EV drive mode switch (integration control and panel sub-assembly) being pushed and held: ON | - |
| Back Up Lamp Relay | Back up light switch condition/ ON or OFF | Shift lever in R ON | - |
| ECO Mode | ECO drive mode transition availability/ ON or OFF | In ECO drive mode: ON |
|
| Generate Torque | Generated drive torque/ Min.: -4096.0 Nm, Max.: 4095.8 Nm | While driving: Varies depending on vehicle operating conditions | - |
| Prohibit Charge for P Pos | HV battery charge in shift lever in P prohibition state/ ON or OFF | HV battery charge in shift lever in P prohibition: ON | - |
| DC/DC Cnv Temp (Upper) | Boost converter temperature (upper)/ Min.: 15°C (59°F), Max.: 150°C (302°F) | Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 15 to 35°C (59 to 95°F) While driving at an ambient temperature of 25°C (77°F): 25 to 110°C (77 to 230°F) | Inverter with converter assembly |
| Safing Signal (Airbag) | Safing state of the airbag sensor assembly/ ON or OFF | When safing state of the airbag sensor assembly: ON | - |
| DC/DC Cnv Temp (Lower) | Boost converter temperature (lower)/ Min.: 15°C (59°F), Max.: 150°C (302°F) | Vehicle left for 1 day at an ambient temperature of 25°C (77°F): 15 to 35°C (59 to 95°F) While driving at an ambient temperature of 25°C (77°F): 25 to 121°C (77 to 250°F) | Inverter with converter assembly |
| Normal Signal for A/B ECU | Control state of airbag sensor assembly/ ON or OFF | When the airbag sensor assembly is operating normally: ON | - |
| Mtr-T (MG1) aftr IG-ON | MG1 temperature soon after power switch on (IG)/ Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Mtr-Temp (MG1) Max | MG1 maximum temperature/ Min.: -40°C (-40°F), Max.: 215°C (419°F) | - | - |
| Overvoltage Input to Conv | Boost converter overvoltage detection/ ON or OFF | Overvoltage is received by the boost converter: ON Normal: OFF | - |
| Overvoltage Input to Inv | Inverter overvoltage detection/ ON or OFF | Overvoltage is received by the inverter: ON Normal: OFF | - |
| Emergency Shutdown | Inverter emergency shutdown/ ON or OFF | Inverter emergency shutdown: ON Normal: OFF | - |
| MG1 Inverter Shutdown | Generator inverter shutdown/ ON or OFF | Generator inverter shutdown: ON Normal: OFF | - |
| MG1 Inverter Fail | Generator inverter failure/ ON or OFF | Generator inverter faulty: ON Normal: OFF | - |
| MG2 Inverter Shutdown | Motor inverter shutdown/ ON or OFF | Motor inverter shutdown: ON Normal: OFF | - |
| MG2 Inverter Fail | Motor inverter failure/ ON or OFF | Motor inverter faulty: ON Normal: OFF | - |
| Conv Shutdown | Boost converter shutdown/ ON or OFF | Boost converter shutdown: ON Normal: OFF | - |
| Converter Fail | Boost converter failure/ ON or OFF | Boost converter faulty: ON Normal: OFF | - |
| Internal Shift Position | ECU internal shift condition/ P/R/N/D/B | Matches currently selected shift position: P, R, N, D or B | - |
| HV Start Condition | Indicates the hybrid start condition/ Norml / Pr A/C / Remote | - | - |
| W/P Run Control Duty | Inverter water pump motor driver request duty/ Min.: 0.00%, Max.: 100.00% | Power switch on (READY): 62.50 to 81.25% | Hybrid vehicle control ECU |
| Engine Stop Request | Engine stop request/ Request or No | Requesting engine stop: Request |
|
| Engine Idling Request | Engine idling request/ Request or No | Requesting idle: Request |
|
| Main Batt Charging Rqst | HV battery charging request/ Request or No | Requesting HV battery charging: Request |
|
| Aircon Request | Engine starting request from air conditioning amplifier assembly/ Request or No | While an engine start is requested from the air conditioning amplifier assembly: Request | Air conditioning amplifier assembly |
| Engine Warming Up Rqst | Engine warm-up request/ Request or No | While an engine warm-up is requested: Request After the engine is warmed up: No |
|
| SMRP Status | Operating state of SMRP/ ON or OFF | Immediately after the power switch on (ST-ON) state occurred: ON After the above timing: OFF | Cannot be confirmed using the intelligent tester. Use an oscilloscope.
|
| SMRB Status | Operating state of SMRB/ ON or OFF | Power switch on (READY): ON |
|
| SMRG Status | Operating state of SMRG/ ON or OFF | Power switch on (READY): ON |
|
| SMRP Control Status | Commanded state of SMRP/ ON or OFF | Immediately after the power switch on (ST-ON) state occurred: ON After the above timing: OFF | Cannot be confirmed using the intelligent tester. Use an oscilloscope. |
| SMRB Control Status | Commanded state of SMRB/ ON or OFF | Power switch on (READY): ON | - |
| SMRG Control Status | Commanded state of SMRG/ ON or OFF | Power switch on (READY): ON | - |
| MG1 Gate Status | MG1 gate status/ ON or OFF | Shutting down generator inverter: ON Normal: OFF |
|
| MG2 Gate Status | MG2 gate status/ ON or OFF | Shutting down motor inverter: ON Normal: OFF |
|
| Converter Gate Status | Boost converter gate status/ ON or OFF | Shutting down boost converter: ON Normal: OFF |
|
| Aircon Gate Status | While A/C inverter is being shut off/ ON or OFF | While A/C inverter is being shut off: ON Normal: OFF |
|
| Converter Carrier Freq | Boost converter signal carrier frequency/ 9.55kHz/9.13kHz/8.71kHz/8.29kHz/7.87kHz/7.45kHz/4.8kHz | - | - |
| Delta SOC | Difference between maximum and minimum values of SOC/ Min.: 0.0%, Max.: 127.5% | READY indicator on, engine stopped and no electrical load: 0.0 to 60.0% | - |
| Batt Pack Current Val | HV battery current/ Min.: -327.68 A, Max.: 327.67 A | Immediately after a full-load acceleration with the engine stopped: Maximum 190.00 A Immediately after engine start with shift lever in P: 100.00 A or more | HV battery current sensor circuit |
| Inhaling Air Temp | HV battery intake air temperature/ Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F) | - | - |
| Auxiliary Battery Vol | Auxiliary battery voltage/ Min.: -40.00 V, Max.: 39.99 V | Same as auxiliary battery voltage |
|
| Charge Control Value | Charge control wattage sent from battery smart unit to hybrid vehicle control ECU/ Min.: -64.0 kW, Max.: 63.5 kW | -33.0 kW or more | - |
| Discharge Control Value | Discharge control wattage sent from battery smart unit to hybrid vehicle control ECU/ Min.: -64.0 kW, Max.: 63.5 kW | 30.0 kW or less | - |
| Cooling Fan Mode1 | Battery cooling blower assembly operation mode/ Min.: 0, Max.: 6 | Power switch on (IG) or on (READY), and battery cooling blower assembly stopped: 0 Power switch on (IG) or on (READY), and battery cooling blower assembly low speed to high speed: 1→6 | Battery cooling fan circuit |
| Cooling Fan Frequency 1 | Battery cooling blower assembly frequency Min.: 0.0 Hz, Max.: 6553.5 Hz | - | Battery cooling fan circuit |
| ECU Control Mode | HV battery control mode/ Min.: 0, Max.: 4 | Driving control mode: 0 Current sensor offset mode: 1 External charge control mode: 2 Power supply end mode: 3 | - |
| Standby Blower Request | Battery cooling blower assembly Lo speed requested/ ON or OFF | Constant: ON or OFF | Air conditioning system |
| Temp of Batt TB1 | Battery module temperature/ Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F) | Undisturbed for 1 day: Same as ambient air temperature |
|
| Temp of Batt TB2 | Battery module temperature/ Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F) | Undisturbed for 1 day: Same as ambient air temperature |
|
| Temp of Batt TB3 | Battery module temperature/ Min.: -50.0°C (-58°F), Max.: 205.9°C (402.6°F) | Undisturbed for 1 day: Same as ambient air temperature |
|
| Battery Block Num | The number of battery blocks | Always: 10 | HV battery |
| Batt Block Minimum Vol | Battery block minimum voltage/ Min.: 0.00 V, Max.: 79.99 V | SOC 55 to 60%: 12.00 V or more | - |
| Minimum Batt Block No | Battery block number with minimum voltage/ Min.: 0, Max.: 10 | Any of block number 0 to 10 | - |
| Batt Block Max Vol | Battery block maximum voltage/ Min.: 0.00 V, Max.: 79.99 V | SOC 55 to 60%: 23.00 V or less | - |
| Max Battery Block No | Battery block number with maximum voltage/ Min.: 0, Max.: 10 | Any of block number 0 to 10 | - |
| Battery Block Vol -V01 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V | SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V02 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V | SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V03 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V | SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V04 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V | SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V05 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V | SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V06 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V | SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V07 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V | SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V08 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V | SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V09 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V | SOC 60% : 12.00 to 20.00 V |
|
| Battery Block Vol -V10 | Battery block voltage/ Min.: 0.00 V, Max.: 79.99 V | SOC 60% : 12.00 to 20.00 V |
|
| Internal Resistance R01 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω | Always: 0.010 to 0.100 Ω | HV battery |
| Internal Resistance R02 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω | Always: 0.010 to 0.100 Ω | HV battery |
| Internal Resistance R03 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω | Always: 0.010 to 0.100 Ω | HV battery |
| Internal Resistance R04 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω | Always: 0.010 to 0.100 Ω | HV battery |
| Internal Resistance R05 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω | Always: 0.010 to 0.100 Ω | HV battery |
| Internal Resistance R06 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω | Always: 0.010 to 0.100 Ω | HV battery |
| Internal Resistance R07 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω | Always: 0.010 to 0.100 Ω | HV battery |
| Internal Resistance R08 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω | Always: 0.010 to 0.100 Ω | HV battery |
| Internal Resistance R09 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω | Always: 0.010 to 0.100 Ω | HV battery |
| Internal Resistance R10 | Internal resistance of each battery block/ Min.: 0.000 Ω, Max.: 0.255 Ω | Always: 0.010 to 0.100 Ω | HV battery |
| Battery Low Time | Cumulative total of extremely low HV battery charge level (engine not startable)/ Min.: 0, Max.: 65535 | - | - |
| DC Inhibit Time | Cumulative total of extremely low HV battery charge level (engine startable)/ Min.: 0, Max.: 65535 | - | - |
| Battery too High Time | Cumulative total of charging during charge prohibition state/ Min.: 0, Max.: 65535 | - | - |
| Hot Temperature Time | Cumulative total of rapid HV battery temperature increase/ Min.: 0, Max.: 65535 | - | - |
| ACTIVE TEST |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Powertrain / Hybrid Control / Active Test.
According to the display on the intelligent tester perform the appropriate Active Test.
| Tester Display | Test Part | Control Range | Test Details | Test Condition |
| Inspection Mode -2WD Inspection*1 | - | - | - | - |
| Inspection Mode -2WD Chassis-Dynamo*1 | - | - | - | - |
| Battery Charge*2 | To charge the HV battery using the THS charger | - | Allows current to flow into the HV battery by operating the SMRS | Power switch on (IG), shift lever in P, and other Active Tests not being performed |
| Compression Test*2 | To crank the engine continuously in order to measure the compression | ON / OFF | Allows the engine to continue cranking by activating MG1 continuously | Power switch on (IG), HV system normal, not in cranking mode, and other Active Tests not being done |
| Activate the Water Pump | To activate the inverter water pump assembly continuously | ON / OFF | Activates the inverter water pump assembly continuously | Power switch on (IG), HV system normal, not in inspection mode, and auxiliary battery voltage is less than 9.5 V or more |
| Driving the Battery Cooling Fan | To check operation of the cooling fan, and check if there is sufficient air flow | 1 to 6 | Stops the cooling fan or changes air volume mode | - |
| Connect the TC and TE1 | Batch display of warnings on combination meter | ON / OFF | TC terminal can be switched ON/OFF | Power switch on (IG), system is normal |