ECU TERMINAL CHART
Terminal No. (Symbols)
| Wiring Color
| Terminal Description
| Condition
| Standard (V)
|
d1-2 (TB2) - d1-8 (GB2)
| L - L
| Battery temperature sensor 2
| HV battery temperature: -40 to 90 °C (-40 to 194 °F)
| 4.8 (-40 °C (-40 °C)) to 1.0 (90 °C (194 °F))
|
d1-3 (TB1) - d1-9 (GB1)
| W - W
| Battery temperature sensor 1
| HV battery temperature: -40 to 90 °C (-40 to 194 °F)
| 4.8 (-40 °C (-40 °C)) to 1.0 (90 °C (194 °F))
|
d1-4 (TBO) - d1-10 (GBO)
| R - R
| Battery temperature sensor 0
| HV battery temperature: -40 to 90 °C (-40 to 194 °F)
| 4.8 (-40 °C (-40 °C)) to 1.0 (90 °C (194 °F))
|
d1-5 (IB) - d1-12 (GIB)
| Y - B
| Current sensor
| Power switch on (READY)
| 0.5 to 4.5
|
d1-6 (VIB) - d1-12 (GIB)
| BR - B
| Power source for battery current sensor
| Power switch on (IG)
| 4.5 to 5.5
|
M39-3 (IGCT) - M39-6 (GND)
| L - W-B
| Control signal
| Power switch on (READY)
| 11 to 14
|
M39-1 (BTH+) - M39-6 (GND)
| R - W-B
| Serial communication
| Power switch on (IG)
| Pulse generation (waveform 1)
|
M39-4 (BTH-) - M39-6 (GND)
| G - W-B
| Serial communication
| Power switch on (IG)
| Pulse generation (waveform 2)
|
M39-5 (FP0) - M39-6 (GND)
| B - W-B
| Battery cooling blower No. 0 monitor signal
| Cooling blower activated
| Pulse generation (waveform 3)
|
Cooling blower stopped
| 4.5 to 5.5 V
|
M39-6 (GND) - Body ground
| W-B
| Ground
| Always (continuity check)
| Below 1 Ω
|