DTC P3004-131 High Voltage Power Resource |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P3004 | 131 | One of the following occurs during pre-charge (the time from when SMRP turns on until SMRG turns on):
|
|
| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| Only P3004-131 is output or P3004-131 and DTCs other than the ones in the table below are also output. | A |
| DTCs shown in Table 1 are output simultaneously. | B |
| DTCs shown in Table 2 are output simultaneously. | C |
| DTC No. | Relevant Diagnosis |
| P06E6-164 | Sensor Power Supply "C" Circuit/Open |
| P0A1A-151, 658 | Generator Control Module |
| P0A1B-786 | Drive Motor "A" Control Module |
| P0A1D-148 | Hybrid Powertrain Control Module |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0AE6-225 | Hybrid Battery Precharge Contactor Control Circuit Low |
| P0AE7-224 | Hybrid Battery Precharge Contactor Control Circuit High |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P0CA3-442 | DC/DC Converter Step Up Voltage Performance |
| P0D2E-586 | Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance |
| P0D2F-266 | Drive Motor "A" Inverter Voltage Sensor Circuit Low |
| P0D30-267 | Drive Motor "A" Inverter Performance |
| P1C2A-155 | Generator A/D Converter Circuit |
| P1C73-512 | Sensor Standard Voltage "F" Circuit/Open |
| P1CA6-156 | Generator Control Module Malfunction |
| P1CA7-193 | Drive Motor Control Module Malfunction |
| P2511-149 | HV CPU Power Relay Sense Circuit Intermittent No Continuity |
| P3004-800, 801 | High Voltage Power Resource |
| P3133-659 | Communication Error from Generator to Drive Motor "A" |
| P3134-661 | Communication Error from Drive Motor "A" to Generator |
| P324E-788 | MG-ECU Power Relay Intermittent Circuit |
| U0110 (all INF codes)*1 | Lost Communication with Drive Motor Control Module "A" |
| DTC No. | Relevant Diagnosis |
| P0A95-123 | High Voltage Fuse |
| P0ABF-123 | Hybrid Battery Pack Current Sensor Circuit |
| P0AC0-123 | Hybrid Battery Pack Current Sensor Circuit Range / Performance |
| P0AC1-123 | Hybrid Battery Pack Current Sensor "A" Circuit Low |
| P0AC2-123 | Hybrid Battery Pack Current Sensor "A" Circuit High |
| P0AFC-123 | Hybrid Battery Pack Sensor Module |
| P0B3D-123 | Hybrid Battery Voltage Sensor "A" Circuit Low |
| P0B42-123 | Hybrid Battery Voltage Sensor "B" Circuit Low |
| P0B47-123 | Hybrid Battery Voltage Sensor "C" Circuit Low |
| P0B4C-123 | Hybrid Battery Voltage Sensor "D" Circuit Low |
| P0B51-123 | Hybrid Battery Voltage Sensor "E" Circuit Low |
| P0B56-123 | Hybrid Battery Voltage Sensor "F" Circuit Low |
| P0B5B-123 | Hybrid Battery Voltage Sensor "G" Circuit Low |
| P0B60-123 | Hybrid Battery Voltage Sensor "H" Circuit Low |
| P0B65-123 | Hybrid Battery Voltage Sensor "I" Circuit Low |
| P0B6A-123 | Hybrid Battery Voltage Sensor "J" Circuit Low |
| P0B6F-123 | Hybrid Battery Voltage Sensor "K" Circuit Low |
| P308A-123 | Hybrid Battery Voltage Sensor All Circuits Low |
| U029A-123 | Lost Communication with Hybrid Battery Pack Sensor Module |
Turn the power switch off.
|
| ||||
|
| ||||
| A | |
| 2.CHECK FREEZE FRAME DATA (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read the freeze frame data of DTC P3004-131.
| Result | Proceed to |
Both of the following conditions are met:
| A |
| Other than above | B |
Turn the power switch off.
|
| ||||
| A | ||
| ||
| 3.CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR) |
![]() |
Check the connector connections and contact pressure of the relevant terminals for the hybrid vehicle control ECU connectors (Click here).
| *A | for LHD |
| *B | for RHD |
|
| ||||
| OK | |
| 4.CHECK INVERTER WITH CONVERTER ASSEMBLY (FRAME WIRE CONNECTION CONDITION) |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Remove the inverter cover from the inverter with converter assembly.
![]() |
Check the connector P1 connection condition between the frame wire and the inverter with converter assembly.
Disconnect connector P1 of the frame wire from the inverter with converter assembly.
Check for arc marks on the terminals of the frame wire.
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the frame wire to the inverter with converter assembly.
Install the inverter cover.
Install the inverter terminal cover.
|
| ||||
|
| ||||
| A | |
| 5.CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (FRAME WIRE CONNECTION CONDITION) |
Check that the service plug grip is not installed.
Remove the No. 1 hybrid vehicle battery cover panel LH .
![]() |
Check the connector P5 and connector P4 connection condition between the frame wire and the hybrid battery junction block assembly.
Disconnect connector P5 and connector P4 of the frame wire from the hybrid battery junction block assembly.
Check for arc marks on the terminals of the frame wire.
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the frame wire to the hybrid battery junction block assembly.
Install the No. 1 hybrid vehicle battery cover panel LH.
|
| ||||
|
| ||||
| A | |
| 6.CHECK FRAME WIRE (INVERTER WITH CONVERTER ASSEMBLY - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY) |
Check that the service plug grip is not installed.
![]() |
Remove the inverter terminal cover from the inverter with converter assembly.
![]() |
Remove the inverter cover from the inverter with converter assembly.
![]() |
Disconnect connector P1 of the frame wire from the inverter with converter assembly.
Remove the No. 1 hybrid vehicle battery cover panel LH .
![]() |
Disconnect connector P5 and connector P4 of the frame wire from the hybrid battery junction block assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| P5-1 (CBI) - P1-2 (CBI) | Power switch off | Below 1 Ω |
| P4-1 (CEI) - P1-1 (CEI) | Power switch off | Below 1 Ω |
| *a | Frame wire (Inverter with Converter Assembly Side) |
| *b | Frame wire (Hybrid Battery Junction Block Assembly Side) |
Connect the frame wire to the hybrid battery junction block assembly.
Install the No. 1 hybrid vehicle battery cover panel LH.
Connect the frame wire to the inverter with converter assembly.
Install the inverter cover.
Install the inverter terminal cover.
|
| ||||
| OK | |
| 7.CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (HV BATTERY HIGH VOLTAGE TERMINAL CONNECTION CONDITION) |
Check that the service plug grip is not installed.
Remove the No. 2 hybrid battery shield sub-assembly .
![]() |
Check the connections between the HV battery high voltage terminals and the hybrid battery junction block assembly.
Disconnect the HV battery high voltage terminals from the hybrid battery junction block assembly.
Check for arc marks on the terminals of the HV battery high voltage terminals.
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the HV battery high voltage terminals.
Install the No. 2 hybrid battery shield sub-assembly.
|
| ||||
|
| ||||
| A | |
| 8.CHECK HV BATTERY |
Check that the service plug grip is not installed.
Remove the No. 2 hybrid battery shield sub-assembly .
![]() |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A-1 (+) - Service plug grip terminal 1 | Power switch off | 66 V or higher |
| c1-1 (-) - Service plug grip terminal 2 | Power switch off | 54 V or higher |
Install the No. 2 hybrid battery shield sub-assembly.
|
| ||||
| OK | |
| 9.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY) |
Check that the service plug grip is not installed.
Disconnect connector G80 from the hybrid vehicle control ECU.
Remove the No. 1 hybrid vehicle battery cover panel LH .
Disconnect the connector M40 that drives the system main relay of the hybrid battery junction block assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| G80-4 (SMRB) - M40-1 (SMRB) | Power switch off | Below 1 Ω |
| G80-3 (SMRP) - M40-4 (SMRP) | Power switch off | Below 1 Ω |
| *a | Rear view of wire harness connector (to Hybrid Vehicle Control ECU) |
| *b | Rear view of wire harness connector (to Hybrid Battery Junction Block Assembly) |
Connect the hybrid battery junction block assembly connector.
Install the No. 1 hybrid vehicle battery cover panel LH.
Connect the hybrid vehicle control ECU connector.
|
| ||||
| OK | |
| 10.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRB) |
Check that the service plug grip is not installed.
Remove the hybrid battery junction block assembly (Click here).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| P5-1 (CBI) - A-1 (+) | Auxiliary battery voltage is applied between terminals M40-1 (SMRB) and M40-2 (GND) | Below 1 Ω |
| *a | Component without harness connected (Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| M40-1 (SMRB) - M40-2 (GND) | -40 to 80 °C (-40 to 176°F) | 25.0 to 59.0 Ω |
Install the hybrid battery junction block assembly.
|
| ||||
| OK | |
| 11.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRP) |
Check that the service plug grip is not installed.
Remove the hybrid battery junction block assembly (Click here).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| P4-1 (CEI) - c1-1 (-) | Auxiliary battery voltage is applied between terminals M40-4 (SMRP) and M40-2 (GND) | 28.5 to 31.5 Ω |
| *a | Component without harness connected (Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| M40-4 (SMRP) - M40-2 (GND) | -40 to 80 °C (-40 to 176°F) | 112 to 274 Ω |
Install the hybrid battery junction block assembly.
|
| ||||
| OK | |
| 12.CHECK FOR INTERMITTENT PROBLEMS |
|
| ||||
| OK | ||
| ||