DTC P0AA1-233 Hybrid Battery Positive Contactor Circuit Stuck Closed |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0AA1 | 233 | SMRP, SMRB and SMRG on the HV battery positive and negative sides are stuck closed. |
|
| 1.CHECK DTC OUTPUT (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
| Only P0AA1-233 is output or P0AA1-233 and DTCs other than the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P06B0-163 | Sensor Power Supply "A" Circuit/Open |
| P06D6-511 | Sensor Reference Voltage "F" Circuit/Open |
| P06E6-164 | Sensor Power Supply "C" Circuit/Open |
| P0A1A-151, 658, 791 | Generator Control Module |
| P0A1B-786, 794 | Drive Motor "A" Control Module |
| P0A1D-148 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0AE7-224 | Hybrid Battery Precharge Contactor Control Circuit High |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P0CA3-442 | DC/DC Converter Step Up Voltage Performance |
| P0D2E-586 | Drive Motor "A" Inverter Voltage Sensor Circuit Range/Performance |
| P0D2F-266 | Drive Motor "A" Inverter Voltage Sensor Circuit Low |
| P0D30-267 | Drive Motor "A" Inverter Performance |
| P1C2A-155 | Generator A/D Converter Circuit |
| P1C73-512 | Sensor Standard Voltage "F" Circuit/Open |
| P1CA6-156 | Generator Control Module Malfunction |
| P1CA7-193 | Drive Motor Control Module Malfunction |
| P1CAC-200 | Generator Position Sensor Angle Malfunction |
| P1CAD-168 | Drive Motor "A" Position Sensor Angle Malfunction |
| P1CAF-792 | Generator Position Sensor REF Signal Cycle Malfunction |
| P1CB0-795 | Drive Motor "A" Position Sensor REF Signal Cycle Malfunction |
| P1CB2-793 | Generator Position Sensor REF Signal Stop Malfunction |
| P1CB3-796 | Drive Motor "A" Position Sensor REF Signal Stop Malfunction |
| P2511-149 | HV CPU Power Relay Sense Circuit Intermittent No Continuity |
| P3004-132 | High Voltage Power Resource |
| P3133-659 | Communication Error from Generator to Drive Motor "A" |
| P3134-661 | Communication Error from Drive Motor "A" to Generator |
| P324E-788 | MG-ECU Power Relay Intermittent Circuit |
| U0110 (all INF codes)*1 | Lost Communication with Drive Motor Control Module "A" |
Turn the power switch off.
|
| ||||
| A | |
| 2.CHECK FREEZE FRAME DATA (HYBRID CONTROL) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Read the freeze frame data of DTC P0AA1-233.
| Result | Proceed to |
| "VH-Voltage after Boosting" minus "VL-Voltage before Boosting" is 100 V or less. | A |
| The preceding condition is not satisfied. | B |
Turn the power switch off.
|
| ||||
| A | |
| 3.CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR) |
![]() |
Check the connector connections and contact pressure of the relevant terminals for the hybrid vehicle control ECU connectors (Click here).
| *A | for LHD |
| *B | for RHD |
|
| ||||
|
| ||||
| 4.CONNECT SECURELY |
| NEXT | |
| 5.CHECK CONNECTOR CONNECTION CONDITION (FLOOR WIRE CONNECTOR) |
Check the connection condition of the MG5 floor wire connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter (Click here).
| Result | Proceed to |
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
|
| ||||
|
| ||||
|
| ||||
| 6.CONNECT SECURELY |
|
| ||||
| 7.REPAIR OR REPLACE HARNESS OR CONNECTOR |
| NEXT | |
| 8.CHECK CONNECTOR CONNECTION CONDITION (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY CONNECTOR) |
Check that the service plug grip is not installed.
Remove the No. 1 hybrid vehicle battery cover panel LH .
![]() |
Check the connector connections and contact pressure of the relevant terminals for the hybrid battery junction block assembly connector (Click here ).
Install the No. 1 hybrid vehicle battery cover panel LH.
|
| ||||
|
| ||||
| 9.CONNECT SECURELY |
| NEXT | |
| 10.CHECK GROUND WIRE CONNECTION CONDITION (SMR ACTIVATION LOW-VOLTAGE CIRCUIT) |
Check the installation condition of the G6 ground wire.
|
| ||||
|
| ||||
| 11.CONNECT SECURELY |
| NEXT | |
| 12.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - HYBRID BATTERY JUNCTION BLOCK ASSEMBLY) |
Check that the service plug grip is not installed.
Remove the No. 1 hybrid vehicle battery cover panel LH .
Disconnect connector M40 from the hybrid battery junction block assembly.
Disconnect connector G80 from the hybrid vehicle control ECU.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| G80-4 (SMRB) - M40-1 (SMRB) | power switch off | Below 1 Ω |
| G80-1 (SMRG) - M40-3 (SMRG) | power switch off | Below 1 Ω |
| G80-3 (SMRP) - M40-4 (SMRP) | power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| G80-4 (SMRB) and M40-1 (SMRB) - Body ground and other terminals | power switch off | 10 kΩ or higher |
| G80-1 (SMRG) and M40-3 (SMRG) - Body ground and other terminals | power switch off | 10 kΩ or higher |
| G80-3 (SMRP) and M40-4 (SMRP) - Body ground and other terminals | power switch off | 10 kΩ or higher |
| *a | Rear view of wire harness connector (to Hybrid Vehicle Control ECU) |
| *b | Rear view of wire harness connector (to Hybrid Battery Junction Block Assembly) |
Connect the hybrid vehicle control ECU connector.
Connect the hybrid battery junction block assembly connector.
Install the No. 1 hybrid vehicle battery cover panel LH.
|
| ||||
|
| ||||
| 13.REPAIR OR REPLACE HARNESS OR CONNECTOR |
| NEXT | |
| 14.CHECK HARNESS AND CONNECTOR (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY- BODY GROUND) |
Check that the service plug grip is not installed.
Remove the No. 1 hybrid vehicle battery cover panel LH .
Disconnect connector M40 from the hybrid battery junction block assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| M40-2 (GND) - Body ground | Power switch off | Below 1 Ω |
| *a | Rear view of wire harness connector (to Hybrid Battery Junction Block Assembly) |
Connect the hybrid battery junction block assembly connector.
Install the No. 1 hybrid vehicle battery cover panel LH.
|
| ||||
|
| ||||
| 15.REPAIR OR REPLACE HARNESS OR CONNECTOR |
| NEXT | |
| 16.INSPECT HYBRID BATTERY JUNCTION BLOCK ASSEMBLY (SMRB, SMRG, SMRP) |
Check that the service plug grip is not installed.
Remove the No. 1 hybrid vehicle battery cover panel LH .
Disconnect connector M40 from the hybrid battery junction block assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| M40-1 (SMRB) - M40-2 (GND) | -40 to 80 °C (-40 to 176°F) | 25.0 to 59.0 Ω |
| M40-3 (SMRG) - M40-2 (GND) | -40 to 80 °C (-40 to 176°F) | 25.0 to 59.0 Ω |
| M40-4 (SMRP) - M40-2 (GND) | -40 to 80 °C (-40 to 176°F) | 112 to 274 Ω |
| *a | Component without harness connected (Hybrid Battery Junction Block Assembly) |
Connect the hybrid battery junction block assembly connector.
Install the No. 1 hybrid vehicle battery cover panel LH.
|
| ||||
| OK | |
| 17.CHECK HYBRID BATTERY JUNCTION BLOCK ASSEMBLY |
Check that the service plug grip is not installed.
Remove the No. 2 hybrid battery shield sub-assembly .
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| P5-1 (CBI) - A-1 (+) | Power switch off | 10 kΩ or higher |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| P4-1 (CEI) - c1-1 (-) | Power switch off | 10 kΩ or higher |
Install the No. 2 hybrid battery shield sub-assembly.
|
| ||||
| OK | |
| 18.REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY |
| NEXT | |
| 19.CHECK HYBRID VEHICLE CONTROL ECU (CHECK FOR NORMAL OPERATION) |
Install the service plug grip.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Clear the DTCs (Click here).
Turn the power switch off and wait for 30 seconds or more.
Turn the power switch on (READY).
Enter the following menus: Powertrain / Hybrid Control / Data List / Power Resource VB, VL-Voltage before Boosting.
According to the display on the intelligent tester, read the Data List and monitor the values of "Power Resource VB" and "VL-Voltage before Boosting" for 3 minutes.
| Result | Proceed to |
| Difference between "Power Resource VB" and "VL-Voltage before Boosting" is always less than 100 V. | A |
| Difference between "Power Resource VB" and "VL-Voltage before Boosting" is 100 V or more. | B |
|
| ||||
| A | ||
| ||