Home › Engine / Hybrid System › 2ZR-FXE ENGINE CONTROL › SFI SYSTEM
NM3210E _51 Engine / Hybrid System _049523 2ZR-FXE ENGINE CONTROL _0249540 SFI SYSTEM DE DETAILS F

2ZR-FXE ENGINE CONTROL  SFI SYSTEM  DETAILS  AIR FUEL RATIO SENSOR  


CONSTRUCTION


a.

A planar type air fuel ratio sensor is used.


b.

The planar type air fuel ratio sensor uses alumina, which excels in heat conductivity and electrical insulation, to integrate a sensor element with a heater, thus improving the warm-up performance of the sensor.

W130672C01
1.063,0.823 2.073,0.823 true 1.031,2.333 2.042,2.333 true 4.135,1.417 4.573,1.417 true 4.146,1.719 4.656,1.719 true 4.906,1.302 5.344,1.302 true 4.813,1.719 5.344,1.719 true 4.771,1.625 4.865,1.042 4.865,1.042 5.188,1.042 true 4.875,1.99 5.333,1.99 true 4.979,2.177 5.313,2.177 true 4.448,2.396 4.583,2.396 4.583,2.396 4.719,2.198 true 0.875,0.729 1.073,0.917 0.198,0.188 10 false *1 0.844,2.24 1.021,2.438 0.177,0.198 10 false *2 3.958,1.323 4.146,1.521 0.188,0.198 10 false *3 3.958,1.625 4.135,1.823 0.177,0.198 10 false *4 4.26,2.302 4.448,2.49 0.188,0.188 10 false *5 5.375,1.208 5.573,1.396 0.198,0.188 10 false *6 5.375,1.615 5.583,1.802 0.208,0.188 10 false *a 5.344,2.073 5.542,2.26 0.198,0.188 10 false *b 5.354,1.885 5.542,2.083 0.188,0.198 10 false *3 5.219,0.938 5.396,1.135 0.177,0.198 10 false *4
*1 Air Fuel Ratio Sensor (Planar Type) *2 Cover
*3 Alumina *4 Platinum Electrode
*5 Sensor Element (Zirconia) *6 Heater
*a Atmosphere *b Coating (Ceramic)



c.

As illustrated below, a conventional heated oxygen sensor is characterized by a sudden change in its output voltage at the threshold of the stoichiometric air fuel ratio (14.7:1). In contrast, the air fuel ratio sensor data is approximately proportionate to the existing air fuel ratio. The air fuel ratio sensor converts the oxygen density into a voltage signal and sends it to the ECM. As a result, the detection precision of the air fuel ratio has been improved. Air fuel ratio sensor data can be viewed using the Global TechStream (GTS).

W131725E03
2.344,0.344 2.531,0.344 2.531,0.344 3.031,1.177 true 4.365,1.385 4.583,0.365 4.583,0.365 4.802,0.365 true 0.875,0.229 2.365,0.458 1.49,0.229 10 false Heated Oxygen Sensor 1.927,0.594 2.167,0.813 0.24,0.219 10 false (V) 1.656,0.771 1.896,0.99 0.24,0.219 10 false 4.2 1.677,3.219 1.917,3.438 0.24,0.219 10 false 2.2 0.583,1.302 1.938,1.719 1.354,0.417 10 false Air Fuel Ratio Sensor Output* 0.583,2.01 1.823,2.688 1.24,0.677 10 false (Data Displayed on the Global TechStream (GTS)) 4.854,0.26 6.25,0.479 1.396,0.219 10 false Air Fuel Ratio Sensor 5.198,0.625 5.438,0.844 0.24,0.219 10 false (V) 5.406,0.781 5.646,1 0.24,0.219 10 false 1 5.396,3.229 5.646,3.427 0.25,0.198 10 false 0.1 5.365,1.896 6.385,2.354 1.021,0.458 10 false Heated Oxygen Sensor Output 2.146,3.615 2.385,3.833 0.24,0.219 10 false 11 3.354,3.615 3.667,3.813 0.313,0.198 10 false 14.7 5.052,3.615 5.25,3.813 0.198,0.198 10 false 19 2.344,3.604 2.75,3.833 0.406,0.229 10 false (Rich) 5.26,3.615 5.688,3.833 0.427,0.219 10 false (Lean) 3.063,3.896 3.958,4.135 0.896,0.24 10 false Air Fuel Ratio 0.208,4.313 6.604,4.563 6.396,0.25 10 false *: This value is calculated internally in the ECM and is not an ECM terminal voltage.