Home › Power Source / Network › POWER DISTRIBUTION › INTEGRATION RELAY
RM3210E _57 Power Source / Network _047508 POWER DISTRIBUTION _0227180 INTEGRATION RELAY A

POWER DISTRIBUTION  INTEGRATION RELAY  INSTALLATION  


PROCEDURE

Hide 82641 1.INSTALL NO. 1 INTEGRATION RELAY

a.

Connect the 2 connectors.


b.
E336556C01
0,0 0,0 false
V113147

Install in this Direction


Engage the 2 claws to install the No. 1 integration relay as shown in the illustration.


Hide 82662A 2.INSTALL NO. 1 RELAY BLOCK COVER

a.
E336552C01
0,0 0,0 false
V113147

Install in this Direction


Engage the 3 claws to install the No. 1 relay block cover as shown in the illustration.


Hide 3.CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL

NOTICE:

When disconnecting the cable, some systems need to be initialized after the cable is reconnected.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION