84330
1.INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY
| *a | Component without harness connected
(Hazard Warning Signal Switch Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 5 (TB) - 4 (E) | Hazard warning signal switch off | 1 MΩ or higher |
| Hazard warning signal switch on | Below 50 Ω |
If the result is not as specified, replace the hazard warning signal switch assembly.
| *a | Component without harness connected
(Hazard Warning Signal Switch Assembly) |
Illumination Inspection
Apply auxiliary battery voltage to the hazard warning signal switch assembly and check that the switch illuminates.
| Condition | Specified Condition |
|---|---|
| Auxiliary battery positive (+) → Terminal 6 (ILL+)
Auxiliary battery negative (-) → Terminal 3 (ILL-) |
Illuminates |
If the result is not as specified, replace the hazard warning signal switch assembly.